{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/77954"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/77954","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Development of an in-situ detector for dissolved gases in liquid waste","abstract":"Monitoring volatile compounds in sewer systems is highly important due to the toxic and corrosive nature of various nuisance chemicals generated, such as hydrogen sulfide (H₂S). Hotspot monitoring facilitates identification of the location of the generated H₂S, and thereby targeted treatment can be applied, which eventually minimizes the use of chemicals and lowers the environmental effect within the sewer system. In this thesis, we present a portable detector that is designed to extract volatile components from aqueous samples by vaporizing the sample and then exposing it to a microfluidic-based detector, fabricated by a selective microchannel embedded with a metal oxide semiconductor (MOS) sensor. The setup consists of an exposure and recovery chamber, heater, servo, and a peristaltic liquid pump. The entire device is controlled using a microcomputer that transmits sensor data and receives inputs from the user. A testing procedure is also established for the setup, which consists of 5 steps, including sample extraction, vaporization, exposure, recovery, and purging. Using a wide concentration ranges of H₂S and ammonia (NH₃) dissolved in water (i.e., two components which the MOS sensor has potential cross-selectivity), a database for classification and regression was developed: the device was capable of classifying between NH₃ and H₂S by a recall value of 100% and 96% in separate and also returned a recall value of 97% with H₂S classification and 96% with NH3 classification in mixture aqueous solutions. Regression precision for separate and mixture aqueous solutions was 84.6% and 88.77%, respectively. The developed setup was used in a field test (at Annacis Island (Delta, BC) wastewater treatment plant (AI-WWTP)) where various tasks such as sample extraction, evaporation, and data transmission were automatically performed. The results show that the device is capable of identifying and measuring the concentration of H₂S and NH₃ in raw influent with 83.48% precision. Overall, the results presented show the potential of the proposed automated wireless device in recognizing and measuring NH₃ and H₂S in sewer systems which can facilitate the detection of hotspots, reduction of treatment costs, increase of the lifespan of buried infrastructure, and minimization of the involvement of highly-skilled personnel.","abstract_html":"Monitoring volatile compounds in sewer systems is highly important due to the toxic and corrosive nature of various nuisance chemicals generated, such as hydrogen sulfide (H₂S). Hotspot monitoring facilitates identification of the location of the generated H₂S, and thereby targeted treatment can be applied, which eventually minimizes the use of chemicals and lowers the environmental effect within the sewer system. In this thesis, we present a portable detector that is designed to extract volatile components from aqueous samples by vaporizing the sample and then exposing it to a microfluidic-based detector, fabricated by a selective microchannel embedded with a metal oxide semiconductor (MOS) sensor. The setup consists of an exposure and recovery chamber, heater, servo, and a peristaltic liquid pump. The entire device is controlled using a microcomputer that transmits sensor data and receives inputs from the user. A testing procedure is also established for the setup, which consists of 5 steps, including sample extraction, vaporization, exposure, recovery, and purging. Using a wide concentration ranges of H₂S and ammonia (NH₃) dissolved in water (i.e., two components which the MOS sensor has potential cross-selectivity), a database for classification and regression was developed: the device was capable of classifying between NH₃ and H₂S by a recall value of 100% and 96% in separate and also returned a recall value of 97% with H₂S classification and 96% with NH3 classification in mixture aqueous solutions. Regression precision for separate and mixture aqueous solutions was 84.6% and 88.77%, respectively. The developed setup was used in a field test (at Annacis Island (Delta, BC) wastewater treatment plant (AI-WWTP)) where various tasks such as sample extraction, evaporation, and data transmission were automatically performed. The results show that the device is capable of identifying and measuring the concentration of H₂S and NH₃ in raw influent with 83.48% precision. Overall, the results presented show the potential of the proposed automated wireless device in recognizing and measuring NH₃ and H₂S in sewer systems which can facilitate the detection of hotspots, reduction of treatment costs, increase of the lifespan of buried infrastructure, and minimization of the involvement of highly-skilled personnel.","abstract_has_math":false,"creators":["Davoodabadi Farahani, Ali"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T15:12:20Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/77954","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/77954","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/77954/1/ubc_2021_may_davoodabadifarahani_ali.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F77954","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Davoodabadi Farahani, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/77954","http://circle.library.ubc.ca/bitstream/2429/77954/1/ubc_2021_may_davoodabadifarahani_ali.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Monitoring volatile compounds in sewer systems is highly important due to the toxic and corrosive nature of various nuisance chemicals generated, such as hydrogen sulfide (H₂S). Hotspot monitoring facilitates identification of the location of the generated H₂S, and thereby targeted treatment can be applied, which eventually minimizes the use of chemicals and lowers the environmental effect within the sewer system. In this thesis, we present a portable detector that is designed to extract volatile components from aqueous samples by vaporizing the sample and then exposing it to a microfluidic-based detector, fabricated by a selective microchannel embedded with a metal oxide semiconductor (MOS) sensor. The setup consists of an exposure and recovery chamber, heater, servo, and a peristaltic liquid pump. The entire device is controlled using a microcomputer that transmits sensor data and receives inputs from the user. A testing procedure is also established for the setup, which consists of 5 steps, including sample extraction, vaporization, exposure, recovery, and purging. Using a wide concentration ranges of H₂S and ammonia (NH₃) dissolved in water (i.e., two components which the MOS sensor has potential cross-selectivity), a database for classification and regression was developed: the device was capable of classifying between NH₃ and H₂S by a recall value of 100% and 96% in separate and also returned a recall value of 97% with H₂S classification and 96% with NH3 classification in mixture aqueous solutions. Regression precision for separate and mixture aqueous solutions was 84.6% and 88.77%, respectively. The developed setup was used in a field test (at Annacis Island (Delta, BC) wastewater treatment plant (AI-WWTP)) where various tasks such as sample extraction, evaporation, and data transmission were automatically performed. The results show that the device is capable of identifying and measuring the concentration of H₂S and NH₃ in raw influent with 83.48% precision. Overall, the results presented show the potential of the proposed automated wireless device in recognizing and measuring NH₃ and H₂S in sewer systems which can facilitate the detection of hotspots, reduction of treatment costs, increase of the lifespan of buried infrastructure, and minimization of the involvement of highly-skilled personnel."]},{"key":"dc:format","label":"Dc Format","values":["2432537","application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of an in-situ detector for dissolved gases in liquid waste"]}]}],"canonical_facts":{"dc:creator":["Davoodabadi Farahani, Ali"],"dc:date":["2021"],"dc:description":["Monitoring volatile compounds in sewer systems is highly important due to the toxic and corrosive nature of various nuisance chemicals generated, such as hydrogen sulfide (H₂S). Hotspot monitoring facilitates identification of the location of the generated H₂S, and thereby targeted treatment can be applied, which eventually minimizes the use of chemicals and lowers the environmental effect within the sewer system. In this thesis, we present a portable detector that is designed to extract volatile components from aqueous samples by vaporizing the sample and then exposing it to a microfluidic-based detector, fabricated by a selective microchannel embedded with a metal oxide semiconductor (MOS) sensor. The setup consists of an exposure and recovery chamber, heater, servo, and a peristaltic liquid pump. The entire device is controlled using a microcomputer that transmits sensor data and receives inputs from the user. A testing procedure is also established for the setup, which consists of 5 steps, including sample extraction, vaporization, exposure, recovery, and purging. Using a wide concentration ranges of H₂S and ammonia (NH₃) dissolved in water (i.e., two components which the MOS sensor has potential cross-selectivity), a database for classification and regression was developed: the device was capable of classifying between NH₃ and H₂S by a recall value of 100% and 96% in separate and also returned a recall value of 97% with H₂S classification and 96% with NH3 classification in mixture aqueous solutions. Regression precision for separate and mixture aqueous solutions was 84.6% and 88.77%, respectively. The developed setup was used in a field test (at Annacis Island (Delta, BC) wastewater treatment plant (AI-WWTP)) where various tasks such as sample extraction, evaporation, and data transmission were automatically performed. The results show that the device is capable of identifying and measuring the concentration of H₂S and NH₃ in raw influent with 83.48% precision. Overall, the results presented show the potential of the proposed automated wireless device in recognizing and measuring NH₃ and H₂S in sewer systems which can facilitate the detection of hotspots, reduction of treatment costs, increase of the lifespan of buried infrastructure, and minimization of the involvement of highly-skilled personnel."],"dc:format":["2432537","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/77954","http://circle.library.ubc.ca/bitstream/2429/77954/1/ubc_2021_may_davoodabadifarahani_ali.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Development of an in-situ detector for dissolved gases in liquid waste"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:12:20Z"}