{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/84175"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/84175","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Evaluating the functional recovery performance of a 1970s non-ductile reinforced concrete shear wall building","abstract":"As seismic design in Canada continues to evolve, many buildings designed to previous building code editions are left to their own devices, creating a vulnerability in communities exposed to large earthquakes. This thesis will examine the preparedness of communities in the lower mainland of British Columbia in the event of a M9 megathrust earthquake. It originates from the Cascadia Subduction Zone, a seismic source off the west coast of Canada and the United States. The focus of this thesis will be on the seismic performance of tall, pre-1980s, reinforced concrete shear wall buildings, which represent a large proportion of Vancouver’s tall buildings. A nonlinear dynamic analysis of an archetype building fitting the mentioned criteria was carried out using shell elements in LS-Dyna. Furthermore, using the FEMA P-2018 rating system, a rapid screening tool that assigns a rating to indicate relative collapse risk for each building considered, a general picture of the risk these building pose to the community could be formed. In recognition that collapse safety is not enough to create a more resilient community, as part of this study, a recently developed framework called TREADS (Tool for Recovery Estimation and Downtime Simulation) is used to describe the performance of the building by following resilience-based performance measures. Results for the nonlinear assessment showed that the archetype building has a large shear capacity due to the large number of walls. However, it is very brittle, and fails abruptly at a low drift ratio. Nevertheless, the FEMA P-2018 showed that this case study building has a rating indicating a relatively low seismic risk. By contrast, the loss and downtime assessment of the building showed that performance would fall short of the target recovery state of shelter-in-place after a 475yr return period earthquake and the target downtime to functional recovery of 4 months. Since the analysis using FEMA P-2018 suggests that the archetype building would perform better relative to other similar buildings, detailed analyses are recommended for any buildings of this type.","abstract_html":"As seismic design in Canada continues to evolve, many buildings designed to previous building code editions are left to their own devices, creating a vulnerability in communities exposed to large earthquakes. This thesis will examine the preparedness of communities in the lower mainland of British Columbia in the event of a M9 megathrust earthquake. It originates from the Cascadia Subduction Zone, a seismic source off the west coast of Canada and the United States. The focus of this thesis will be on the seismic performance of tall, pre-1980s, reinforced concrete shear wall buildings, which represent a large proportion of Vancouver’s tall buildings. A nonlinear dynamic analysis of an archetype building fitting the mentioned criteria was carried out using shell elements in LS-Dyna. Furthermore, using the FEMA P-2018 rating system, a rapid screening tool that assigns a rating to indicate relative collapse risk for each building considered, a general picture of the risk these building pose to the community could be formed. In recognition that collapse safety is not enough to create a more resilient community, as part of this study, a recently developed framework called TREADS (Tool for Recovery Estimation and Downtime Simulation) is used to describe the performance of the building by following resilience-based performance measures. Results for the nonlinear assessment showed that the archetype building has a large shear capacity due to the large number of walls. However, it is very brittle, and fails abruptly at a low drift ratio. Nevertheless, the FEMA P-2018 showed that this case study building has a rating indicating a relatively low seismic risk. By contrast, the loss and downtime assessment of the building showed that performance would fall short of the target recovery state of shelter-in-place after a 475yr return period earthquake and the target downtime to functional recovery of 4 months. Since the analysis using FEMA P-2018 suggests that the archetype building would perform better relative to other similar buildings, detailed analyses are recommended for any buildings of this type.","abstract_has_math":false,"creators":["Si, Jennifer"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":["Molina Hutt, Carlos"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T15:13:28Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/84175","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/84175","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/84175/5/ubc_2023_may_si_jennifer.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F84175","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Molina Hutt, Carlos"]},{"key":"dc:creator","label":"Author","values":["Si, Jennifer"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/84175","http://circle.library.ubc.ca/bitstream/2429/84175/5/ubc_2023_may_si_jennifer.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["As seismic design in Canada continues to evolve, many buildings designed to previous building code editions are left to their own devices, creating a vulnerability in communities exposed to large earthquakes. This thesis will examine the preparedness of communities in the lower mainland of British Columbia in the event of a M9 megathrust earthquake. It originates from the Cascadia Subduction Zone, a seismic source off the west coast of Canada and the United States. The focus of this thesis will be on the seismic performance of tall, pre-1980s, reinforced concrete shear wall buildings, which represent a large proportion of Vancouver’s tall buildings. A nonlinear dynamic analysis of an archetype building fitting the mentioned criteria was carried out using shell elements in LS-Dyna. Furthermore, using the FEMA P-2018 rating system, a rapid screening tool that assigns a rating to indicate relative collapse risk for each building considered, a general picture of the risk these building pose to the community could be formed. In recognition that collapse safety is not enough to create a more resilient community, as part of this study, a recently developed framework called TREADS (Tool for Recovery Estimation and Downtime Simulation) is used to describe the performance of the building by following resilience-based performance measures. Results for the nonlinear assessment showed that the archetype building has a large shear capacity due to the large number of walls. However, it is very brittle, and fails abruptly at a low drift ratio. Nevertheless, the FEMA P-2018 showed that this case study building has a rating indicating a relatively low seismic risk. By contrast, the loss and downtime assessment of the building showed that performance would fall short of the target recovery state of shelter-in-place after a 475yr return period earthquake and the target downtime to functional recovery of 4 months. Since the analysis using FEMA P-2018 suggests that the archetype building would perform better relative to other similar buildings, detailed analyses are recommended for any buildings of this type."]},{"key":"dc:format","label":"Dc Format","values":["4505776","application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluating the functional recovery performance of a 1970s non-ductile reinforced concrete shear wall building"]}]}],"canonical_facts":{"dc:contributor":["Molina Hutt, Carlos"],"dc:creator":["Si, Jennifer"],"dc:date":["2023"],"dc:description":["As seismic design in Canada continues to evolve, many buildings designed to previous building code editions are left to their own devices, creating a vulnerability in communities exposed to large earthquakes. This thesis will examine the preparedness of communities in the lower mainland of British Columbia in the event of a M9 megathrust earthquake. It originates from the Cascadia Subduction Zone, a seismic source off the west coast of Canada and the United States. The focus of this thesis will be on the seismic performance of tall, pre-1980s, reinforced concrete shear wall buildings, which represent a large proportion of Vancouver’s tall buildings. A nonlinear dynamic analysis of an archetype building fitting the mentioned criteria was carried out using shell elements in LS-Dyna. Furthermore, using the FEMA P-2018 rating system, a rapid screening tool that assigns a rating to indicate relative collapse risk for each building considered, a general picture of the risk these building pose to the community could be formed. In recognition that collapse safety is not enough to create a more resilient community, as part of this study, a recently developed framework called TREADS (Tool for Recovery Estimation and Downtime Simulation) is used to describe the performance of the building by following resilience-based performance measures. Results for the nonlinear assessment showed that the archetype building has a large shear capacity due to the large number of walls. However, it is very brittle, and fails abruptly at a low drift ratio. Nevertheless, the FEMA P-2018 showed that this case study building has a rating indicating a relatively low seismic risk. By contrast, the loss and downtime assessment of the building showed that performance would fall short of the target recovery state of shelter-in-place after a 475yr return period earthquake and the target downtime to functional recovery of 4 months. Since the analysis using FEMA P-2018 suggests that the archetype building would perform better relative to other similar buildings, detailed analyses are recommended for any buildings of this type."],"dc:format":["4505776","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/84175","http://circle.library.ubc.ca/bitstream/2429/84175/5/ubc_2023_may_si_jennifer.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Evaluating the functional recovery performance of a 1970s non-ductile reinforced concrete shear wall building"],"dc:type":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:13:28Z"}