{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/85291"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/85291","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Impact of formalin fixation on multi-compartment T2 relaxation and its tissue orientation dependence in excised pig spinal cord white matter","abstract":"In this MRI study, we investigated multi-compartment T₂ relaxation times of fresh, fixed, and washed pig spinal cord white matter (WM) and their dependence on tissue orientation relative to the main magnetic field. Multi-echo spin echo scans from eight pig spinal cord samples were acquired at 9.4 T with their axes parallel to the main magnetic field B₀. Four of these spinal cord segments were imaged at six different orientations with respect to B₀. After fixation, short fraction T₂ times and myelin water fraction (MWF) increased, while long fraction T₂ times decreased. After washing, short and long fraction T₂ times increased relative to fixed tissue, and MWF decreased relative to fresh tissue. We found a considerable orientation dependence in the short fraction relaxation rate R₂ (=1/T₂) in fresh tissue, which is reduced in washed tissue, and absent in fixed tissue. A similar, but reduced, orientation dependence was observed in long fraction R₂. This work presents a direct comparison of orientation dependence in a WM tissue sample in the fresh, fixed, and washed state. Understanding the changes caused by fixation and tissue orientation can aid in the correction of fixation and orientation-induced alterations of MRI metrics for more accurate and reliable measurements.","abstract_html":"In this MRI study, we investigated multi-compartment T₂ relaxation times of fresh, fixed, and washed pig spinal cord white matter (WM) and their dependence on tissue orientation relative to the main magnetic field. Multi-echo spin echo scans from eight pig spinal cord samples were acquired at 9.4 T with their axes parallel to the main magnetic field B₀. Four of these spinal cord segments were imaged at six different orientations with respect to B₀. After fixation, short fraction T₂ times and myelin water fraction (MWF) increased, while long fraction T₂ times decreased. After washing, short and long fraction T₂ times increased relative to fixed tissue, and MWF decreased relative to fresh tissue. We found a considerable orientation dependence in the short fraction relaxation rate R₂ (=1/T₂) in fresh tissue, which is reduced in washed tissue, and absent in fixed tissue. A similar, but reduced, orientation dependence was observed in long fraction R₂. This work presents a direct comparison of orientation dependence in a WM tissue sample in the fresh, fixed, and washed state. Understanding the changes caused by fixation and tissue orientation can aid in the correction of fixation and orientation-induced alterations of MRI metrics for more accurate and reliable measurements.","abstract_has_math":false,"creators":["Medina, Michelle Claudette"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Medical Physics","degree_department":null,"school":null,"contributors":["Rauscher, Alexander"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T15:13:37Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/85291","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/85291","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/85291/6/ubc_2023_november_medina_michelle.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F85291","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rauscher, Alexander"]},{"key":"dc:creator","label":"Author","values":["Medina, Michelle Claudette"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/85291","http://circle.library.ubc.ca/bitstream/2429/85291/6/ubc_2023_november_medina_michelle.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["In this MRI study, we investigated multi-compartment T₂ relaxation times of fresh, fixed, and washed pig spinal cord white matter (WM) and their dependence on tissue orientation relative to the main magnetic field. Multi-echo spin echo scans from eight pig spinal cord samples were acquired at 9.4 T with their axes parallel to the main magnetic field B₀. Four of these spinal cord segments were imaged at six different orientations with respect to B₀. After fixation, short fraction T₂ times and myelin water fraction (MWF) increased, while long fraction T₂ times decreased. After washing, short and long fraction T₂ times increased relative to fixed tissue, and MWF decreased relative to fresh tissue. We found a considerable orientation dependence in the short fraction relaxation rate R₂ (=1/T₂) in fresh tissue, which is reduced in washed tissue, and absent in fixed tissue. A similar, but reduced, orientation dependence was observed in long fraction R₂. This work presents a direct comparison of orientation dependence in a WM tissue sample in the fresh, fixed, and washed state. Understanding the changes caused by fixation and tissue orientation can aid in the correction of fixation and orientation-induced alterations of MRI metrics for more accurate and reliable measurements."]},{"key":"dc:format","label":"Dc Format","values":["12518058","application/pdf"]},{"key":"dc:title","label":"Title","values":["Impact of formalin fixation on multi-compartment T2 relaxation and its tissue orientation dependence in excised pig spinal cord white matter"]}]}],"canonical_facts":{"dc:contributor":["Rauscher, Alexander"],"dc:creator":["Medina, Michelle Claudette"],"dc:date":["2023"],"dc:description":["In this MRI study, we investigated multi-compartment T₂ relaxation times of fresh, fixed, and washed pig spinal cord white matter (WM) and their dependence on tissue orientation relative to the main magnetic field. Multi-echo spin echo scans from eight pig spinal cord samples were acquired at 9.4 T with their axes parallel to the main magnetic field B₀. Four of these spinal cord segments were imaged at six different orientations with respect to B₀. After fixation, short fraction T₂ times and myelin water fraction (MWF) increased, while long fraction T₂ times decreased. After washing, short and long fraction T₂ times increased relative to fixed tissue, and MWF decreased relative to fresh tissue. We found a considerable orientation dependence in the short fraction relaxation rate R₂ (=1/T₂) in fresh tissue, which is reduced in washed tissue, and absent in fixed tissue. A similar, but reduced, orientation dependence was observed in long fraction R₂. This work presents a direct comparison of orientation dependence in a WM tissue sample in the fresh, fixed, and washed state. Understanding the changes caused by fixation and tissue orientation can aid in the correction of fixation and orientation-induced alterations of MRI metrics for more accurate and reliable measurements."],"dc:format":["12518058","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/85291","http://circle.library.ubc.ca/bitstream/2429/85291/6/ubc_2023_november_medina_michelle.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Impact of formalin fixation on multi-compartment T2 relaxation and its tissue orientation dependence in excised pig spinal cord white matter"],"dc:type":["Text"],"thesis:degree_discipline":["Medical Physics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:13:37Z"}