{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/88990"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/88990","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Development of compact multimodal two-photon and three-photon microscopy","abstract":"Multiphoton microscopy (MPM) is an optical microscopy technique visualizing tissues non-invasively in high resolution. MPM utilizes femtosecond laser pulses for multiphoton excitation. MPM provides tissue-specific contrasts that are useful in clinical applications. Two-photon excitation fluorescence (2PEF) visualizes cells; second harmonic generation (SHG) visualizes collagen fibers; third harmonic generation (THG) visualizes lipids. While being utilized in research for decades, clinical applications are still limited. The bulkiness and complexity of free-space lasers, microscope platforms, and scanners prevent convenient clinical use. Different from ex-vivo imaging where labeling can enhance signals, clinical imaging relies on label-free signals which can be significantly weaker. Multimodal MPM with multiple contrasts from two- and three-photon excitations helps clinical imaging enhance biochemical specificity and provide complementary information. Depth-scanning further provides volumetric information about tissue. A handheld MPM imaging head with multimodal and depth-scanning capabilities is needed to carry the technique to clinical applications. This dissertation explores the potential of developing compact depth-scanning multimodal MPM with simultaneous two- and three-photon imaging. Harmonic generation is theoretically analyzed under focused Gaussian beam. The impact of phase-matching is discussed to show interface-sensitivity of SHG and THG. A 1580-nm Er-doped femtosecond fiber laser serves as a compact source for excitation, and part of the laser is converted to 790 nm to achieve dual-wavelength two- and three-photon excitation. Signals of 2PEF, SHG, and THG are separated and then detected by photomultiplier tubes. A signal subtraction method is proposed to address crosstalk. To further improve the compactness, a miniaturized depth-scanning objective (numerical aperture ~0.53) consisting of an aspheric and a plano-convex lens is fabricated. A shape-memory-alloy actuator actuates the aspheric lens for depth scanning over a range of 370 μm. A denoising algorithm is developed to improve the quality of weak-signal images. The denoising method is demonstrated on weak-signal images and compared with other denoising methods, showing outperforming results. Information-rich images containing 2PEF, SHG, and THG contrasts are acquired label-free from animal, human, and plant tissues at various depths up to >200 μm. The performance is evaluated with advantages and limitations discussed. Through this study, the compact depth-scanning multimodal MPM shows great potential for clinical applications.","abstract_html":"Multiphoton microscopy (MPM) is an optical microscopy technique visualizing tissues non-invasively in high resolution. MPM utilizes femtosecond laser pulses for multiphoton excitation. MPM provides tissue-specific contrasts that are useful in clinical applications. Two-photon excitation fluorescence (2PEF) visualizes cells; second harmonic generation (SHG) visualizes collagen fibers; third harmonic generation (THG) visualizes lipids. While being utilized in research for decades, clinical applications are still limited. The bulkiness and complexity of free-space lasers, microscope platforms, and scanners prevent convenient clinical use. Different from ex-vivo imaging where labeling can enhance signals, clinical imaging relies on label-free signals which can be significantly weaker. Multimodal MPM with multiple contrasts from two- and three-photon excitations helps clinical imaging enhance biochemical specificity and provide complementary information. Depth-scanning further provides volumetric information about tissue. A handheld MPM imaging head with multimodal and depth-scanning capabilities is needed to carry the technique to clinical applications. This dissertation explores the potential of developing compact depth-scanning multimodal MPM with simultaneous two- and three-photon imaging. Harmonic generation is theoretically analyzed under focused Gaussian beam. The impact of phase-matching is discussed to show interface-sensitivity of SHG and THG. A 1580-nm Er-doped femtosecond fiber laser serves as a compact source for excitation, and part of the laser is converted to 790 nm to achieve dual-wavelength two- and three-photon excitation. Signals of 2PEF, SHG, and THG are separated and then detected by photomultiplier tubes. A signal subtraction method is proposed to address crosstalk. To further improve the compactness, a miniaturized depth-scanning objective (numerical aperture ~0.53) consisting of an aspheric and a plano-convex lens is fabricated. A shape-memory-alloy actuator actuates the aspheric lens for depth scanning over a range of 370 μm. A denoising algorithm is developed to improve the quality of weak-signal images. The denoising method is demonstrated on weak-signal images and compared with other denoising methods, showing outperforming results. Information-rich images containing 2PEF, SHG, and THG contrasts are acquired label-free from animal, human, and plant tissues at various depths up to &gt;200 μm. The performance is evaluated with advantages and limitations discussed. Through this study, the compact depth-scanning multimodal MPM shows great potential for clinical applications.","abstract_has_math":false,"creators":["Wu, Wentao"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":["Tang, Shuo"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T15:14:19Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/88990","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/88990","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/88990/4/ubc_2024_november_wu_wentao.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F88990","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Tang, Shuo"]},{"key":"dc:creator","label":"Author","values":["Wu, Wentao"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/88990","http://circle.library.ubc.ca/bitstream/2429/88990/4/ubc_2024_november_wu_wentao.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Multiphoton microscopy (MPM) is an optical microscopy technique visualizing tissues non-invasively in high resolution. MPM utilizes femtosecond laser pulses for multiphoton excitation. MPM provides tissue-specific contrasts that are useful in clinical applications. Two-photon excitation fluorescence (2PEF) visualizes cells; second harmonic generation (SHG) visualizes collagen fibers; third harmonic generation (THG) visualizes lipids. While being utilized in research for decades, clinical applications are still limited. The bulkiness and complexity of free-space lasers, microscope platforms, and scanners prevent convenient clinical use. Different from ex-vivo imaging where labeling can enhance signals, clinical imaging relies on label-free signals which can be significantly weaker. Multimodal MPM with multiple contrasts from two- and three-photon excitations helps clinical imaging enhance biochemical specificity and provide complementary information. Depth-scanning further provides volumetric information about tissue. A handheld MPM imaging head with multimodal and depth-scanning capabilities is needed to carry the technique to clinical applications. This dissertation explores the potential of developing compact depth-scanning multimodal MPM with simultaneous two- and three-photon imaging. Harmonic generation is theoretically analyzed under focused Gaussian beam. The impact of phase-matching is discussed to show interface-sensitivity of SHG and THG. A 1580-nm Er-doped femtosecond fiber laser serves as a compact source for excitation, and part of the laser is converted to 790 nm to achieve dual-wavelength two- and three-photon excitation. Signals of 2PEF, SHG, and THG are separated and then detected by photomultiplier tubes. A signal subtraction method is proposed to address crosstalk. To further improve the compactness, a miniaturized depth-scanning objective (numerical aperture ~0.53) consisting of an aspheric and a plano-convex lens is fabricated. A shape-memory-alloy actuator actuates the aspheric lens for depth scanning over a range of 370 μm. A denoising algorithm is developed to improve the quality of weak-signal images. The denoising method is demonstrated on weak-signal images and compared with other denoising methods, showing outperforming results. Information-rich images containing 2PEF, SHG, and THG contrasts are acquired label-free from animal, human, and plant tissues at various depths up to >200 μm. The performance is evaluated with advantages and limitations discussed. Through this study, the compact depth-scanning multimodal MPM shows great potential for clinical applications."]},{"key":"dc:format","label":"Dc Format","values":["43268609","application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of compact multimodal two-photon and three-photon microscopy"]}]}],"canonical_facts":{"dc:contributor":["Tang, Shuo"],"dc:creator":["Wu, Wentao"],"dc:date":["2024"],"dc:description":["Multiphoton microscopy (MPM) is an optical microscopy technique visualizing tissues non-invasively in high resolution. MPM utilizes femtosecond laser pulses for multiphoton excitation. MPM provides tissue-specific contrasts that are useful in clinical applications. Two-photon excitation fluorescence (2PEF) visualizes cells; second harmonic generation (SHG) visualizes collagen fibers; third harmonic generation (THG) visualizes lipids. While being utilized in research for decades, clinical applications are still limited. The bulkiness and complexity of free-space lasers, microscope platforms, and scanners prevent convenient clinical use. Different from ex-vivo imaging where labeling can enhance signals, clinical imaging relies on label-free signals which can be significantly weaker. Multimodal MPM with multiple contrasts from two- and three-photon excitations helps clinical imaging enhance biochemical specificity and provide complementary information. Depth-scanning further provides volumetric information about tissue. A handheld MPM imaging head with multimodal and depth-scanning capabilities is needed to carry the technique to clinical applications. This dissertation explores the potential of developing compact depth-scanning multimodal MPM with simultaneous two- and three-photon imaging. Harmonic generation is theoretically analyzed under focused Gaussian beam. The impact of phase-matching is discussed to show interface-sensitivity of SHG and THG. A 1580-nm Er-doped femtosecond fiber laser serves as a compact source for excitation, and part of the laser is converted to 790 nm to achieve dual-wavelength two- and three-photon excitation. Signals of 2PEF, SHG, and THG are separated and then detected by photomultiplier tubes. A signal subtraction method is proposed to address crosstalk. To further improve the compactness, a miniaturized depth-scanning objective (numerical aperture ~0.53) consisting of an aspheric and a plano-convex lens is fabricated. A shape-memory-alloy actuator actuates the aspheric lens for depth scanning over a range of 370 μm. A denoising algorithm is developed to improve the quality of weak-signal images. The denoising method is demonstrated on weak-signal images and compared with other denoising methods, showing outperforming results. Information-rich images containing 2PEF, SHG, and THG contrasts are acquired label-free from animal, human, and plant tissues at various depths up to >200 μm. The performance is evaluated with advantages and limitations discussed. Through this study, the compact depth-scanning multimodal MPM shows great potential for clinical applications."],"dc:format":["43268609","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/88990","http://circle.library.ubc.ca/bitstream/2429/88990/4/ubc_2024_november_wu_wentao.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Development of compact multimodal two-photon and three-photon microscopy"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:19Z"}