{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/89009"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/89009","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Development of NIR/VIS 3D optical imaging systems for ocular tissue imaging","abstract":"Research and surgery in ophthalmology demand precise details about ocular tissues to study the causes of diseases, examine possible therapies, and assess the suitability of donated tissues. Mouse were commonly studied in preclinical research, which offers significant benefits as research subjects due to their ready availability and the wide array of pathological models they represent. Meanwhile, human corneal transplants require a comprehensive examination of the donor cornea to guarantee the success of the transplant. Optical coherence tomography (OCT) is a noninvasive imaging method that captures high-resolution three-dimensional structures. It has been extensively used in ophthalmology for several years and has progressed to provide details such as cellular structures, melanin distribution, and vascular distribution for ocular tissues. The thesis explores two micro-optical coherence tomography systems in NIR and VIS. Utilizing these two systems, the study examined the mouse model and human and obtained cellular-resolution images of the posterior segment of the eye. These images offer crucial insights for understanding eye diseases and assessing potential treatment approaches. Additionally, high-resolution images of mouse and human corneas were captured to assess the integration of corneal layers and to help increase the effectiveness of corneal transplant procedures.","abstract_html":"Research and surgery in ophthalmology demand precise details about ocular tissues to study the causes of diseases, examine possible therapies, and assess the suitability of donated tissues. Mouse were commonly studied in preclinical research, which offers significant benefits as research subjects due to their ready availability and the wide array of pathological models they represent. Meanwhile, human corneal transplants require a comprehensive examination of the donor cornea to guarantee the success of the transplant. Optical coherence tomography (OCT) is a noninvasive imaging method that captures high-resolution three-dimensional structures. It has been extensively used in ophthalmology for several years and has progressed to provide details such as cellular structures, melanin distribution, and vascular distribution for ocular tissues. The thesis explores two micro-optical coherence tomography systems in NIR and VIS. Utilizing these two systems, the study examined the mouse model and human and obtained cellular-resolution images of the posterior segment of the eye. These images offer crucial insights for understanding eye diseases and assessing potential treatment approaches. Additionally, high-resolution images of mouse and human corneas were captured to assess the integration of corneal layers and to help increase the effectiveness of corneal transplant procedures.","abstract_has_math":false,"creators":["Hu, Yujie"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Ju, Myeong Jin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T15:14:19Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/89009","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/89009","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/89009/4/ubc_2024_november_hu_yujie.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F89009","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ju, Myeong Jin"]},{"key":"dc:creator","label":"Author","values":["Hu, Yujie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/89009","http://circle.library.ubc.ca/bitstream/2429/89009/4/ubc_2024_november_hu_yujie.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Research and surgery in ophthalmology demand precise details about ocular tissues to study the causes of diseases, examine possible therapies, and assess the suitability of donated tissues. Mouse were commonly studied in preclinical research, which offers significant benefits as research subjects due to their ready availability and the wide array of pathological models they represent. Meanwhile, human corneal transplants require a comprehensive examination of the donor cornea to guarantee the success of the transplant. Optical coherence tomography (OCT) is a noninvasive imaging method that captures high-resolution three-dimensional structures. It has been extensively used in ophthalmology for several years and has progressed to provide details such as cellular structures, melanin distribution, and vascular distribution for ocular tissues. The thesis explores two micro-optical coherence tomography systems in NIR and VIS. Utilizing these two systems, the study examined the mouse model and human and obtained cellular-resolution images of the posterior segment of the eye. These images offer crucial insights for understanding eye diseases and assessing potential treatment approaches. Additionally, high-resolution images of mouse and human corneas were captured to assess the integration of corneal layers and to help increase the effectiveness of corneal transplant procedures."]},{"key":"dc:format","label":"Dc Format","values":["18645737","application/pdf"]},{"key":"dc:title","label":"Title","values":["Development of NIR/VIS 3D optical imaging systems for ocular tissue imaging"]}]}],"canonical_facts":{"dc:contributor":["Ju, Myeong Jin"],"dc:creator":["Hu, Yujie"],"dc:date":["2024"],"dc:description":["Research and surgery in ophthalmology demand precise details about ocular tissues to study the causes of diseases, examine possible therapies, and assess the suitability of donated tissues. Mouse were commonly studied in preclinical research, which offers significant benefits as research subjects due to their ready availability and the wide array of pathological models they represent. Meanwhile, human corneal transplants require a comprehensive examination of the donor cornea to guarantee the success of the transplant. Optical coherence tomography (OCT) is a noninvasive imaging method that captures high-resolution three-dimensional structures. It has been extensively used in ophthalmology for several years and has progressed to provide details such as cellular structures, melanin distribution, and vascular distribution for ocular tissues. The thesis explores two micro-optical coherence tomography systems in NIR and VIS. Utilizing these two systems, the study examined the mouse model and human and obtained cellular-resolution images of the posterior segment of the eye. These images offer crucial insights for understanding eye diseases and assessing potential treatment approaches. Additionally, high-resolution images of mouse and human corneas were captured to assess the integration of corneal layers and to help increase the effectiveness of corneal transplant procedures."],"dc:format":["18645737","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/89009","http://circle.library.ubc.ca/bitstream/2429/89009/4/ubc_2024_november_hu_yujie.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Development of NIR/VIS 3D optical imaging systems for ocular tissue imaging"],"dc:type":["Text"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:19Z"}