{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/89410"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/89410","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique","abstract":"Motivated by the growing need for lactate measurement in human biofluids, this study presents a novel fluorescent sensing device that is integrated with a commercial smartphone camera to analyze lactate concentrations. Highly fluorescent carbon quantum dots (CQDs) were chosen as the signal-generating element for the device, and these were modified by nitrogen doping and silica capping for a more robust performance. The molecularly imprinted polymer (MIP) technique was employed to create reception sites on the sensing layer and to provide the sensor with specificity toward lactate molecules. The synthesis was done using 3-aminopropyltriethoxysilane (APTES) as the functional monomer and tetraethyl silicate (TEOS) as the cross-linker to develop the sensor in the initial, liquid phase. Subsequently, the direct polymer deposition method was used to immobilize the sensing layer on small pieces of filter paper (sensing paper) and thus obtain a solid-phase sensor. The sensing papers were tested by exposure to varying lactate concentrations, ranging from 5 to 500 mM, in aqueous media, thus covering the full concentration range of lactate typically found in human sweat. A commercial smartphone camera was used to take photos of the sensing papers, and these photos were later analyzed against red-green-blue (RGB) and hue-saturation-lightness (HSL) color models. Linear correlations between the color values and the lactate concentrations were derived using their blue and saturation values. For concentrations below 100 mM, the blue values changed, showing a consistent pattern in relation to lactate concentrations; while for the higher concentrations of up to 500 mM, the saturation values changed, showing increasing sensitivity. According to the R² values obtained, both correlations were excellent fits with the data. The sensor responses to potentially interfering molecules, including glucose, ascorbic acid, and uric acid, were also evaluated, confirming the device's selectivity for lactate. The sensor fabricated demonstrated promising results for the quantitative measurement of lactate without requiring complex laboratory equipment, and it also showed great potential for further development in measuring other biomarkers in the human body.","abstract_html":"Motivated by the growing need for lactate measurement in human biofluids, this study presents a novel fluorescent sensing device that is integrated with a commercial smartphone camera to analyze lactate concentrations. Highly fluorescent carbon quantum dots (CQDs) were chosen as the signal-generating element for the device, and these were modified by nitrogen doping and silica capping for a more robust performance. The molecularly imprinted polymer (MIP) technique was employed to create reception sites on the sensing layer and to provide the sensor with specificity toward lactate molecules. The synthesis was done using 3-aminopropyltriethoxysilane (APTES) as the functional monomer and tetraethyl silicate (TEOS) as the cross-linker to develop the sensor in the initial, liquid phase. Subsequently, the direct polymer deposition method was used to immobilize the sensing layer on small pieces of filter paper (sensing paper) and thus obtain a solid-phase sensor. The sensing papers were tested by exposure to varying lactate concentrations, ranging from 5 to 500 mM, in aqueous media, thus covering the full concentration range of lactate typically found in human sweat. A commercial smartphone camera was used to take photos of the sensing papers, and these photos were later analyzed against red-green-blue (RGB) and hue-saturation-lightness (HSL) color models. Linear correlations between the color values and the lactate concentrations were derived using their blue and saturation values. For concentrations below 100 mM, the blue values changed, showing a consistent pattern in relation to lactate concentrations; while for the higher concentrations of up to 500 mM, the saturation values changed, showing increasing sensitivity. According to the R² values obtained, both correlations were excellent fits with the data. The sensor responses to potentially interfering molecules, including glucose, ascorbic acid, and uric acid, were also evaluated, confirming the device&#x27;s selectivity for lactate. The sensor fabricated demonstrated promising results for the quantitative measurement of lactate without requiring complex laboratory equipment, and it also showed great potential for further development in measuring other biomarkers in the human body.","abstract_has_math":false,"creators":["Khodaei Tehrani, Ali"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Chemical and Biological Engineering","degree_department":null,"school":null,"contributors":["Taghipour, Fariborz"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T15:14:23Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/89410","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/89410","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/89410/4/ubc_2024_november_khodaeitehrani_ali.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F89410","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Taghipour, Fariborz"]},{"key":"dc:creator","label":"Author","values":["Khodaei Tehrani, Ali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biological Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/89410","http://circle.library.ubc.ca/bitstream/2429/89410/4/ubc_2024_november_khodaeitehrani_ali.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Motivated by the growing need for lactate measurement in human biofluids, this study presents a novel fluorescent sensing device that is integrated with a commercial smartphone camera to analyze lactate concentrations. Highly fluorescent carbon quantum dots (CQDs) were chosen as the signal-generating element for the device, and these were modified by nitrogen doping and silica capping for a more robust performance. The molecularly imprinted polymer (MIP) technique was employed to create reception sites on the sensing layer and to provide the sensor with specificity toward lactate molecules. The synthesis was done using 3-aminopropyltriethoxysilane (APTES) as the functional monomer and tetraethyl silicate (TEOS) as the cross-linker to develop the sensor in the initial, liquid phase. Subsequently, the direct polymer deposition method was used to immobilize the sensing layer on small pieces of filter paper (sensing paper) and thus obtain a solid-phase sensor. The sensing papers were tested by exposure to varying lactate concentrations, ranging from 5 to 500 mM, in aqueous media, thus covering the full concentration range of lactate typically found in human sweat. A commercial smartphone camera was used to take photos of the sensing papers, and these photos were later analyzed against red-green-blue (RGB) and hue-saturation-lightness (HSL) color models. Linear correlations between the color values and the lactate concentrations were derived using their blue and saturation values. For concentrations below 100 mM, the blue values changed, showing a consistent pattern in relation to lactate concentrations; while for the higher concentrations of up to 500 mM, the saturation values changed, showing increasing sensitivity. According to the R² values obtained, both correlations were excellent fits with the data. The sensor responses to potentially interfering molecules, including glucose, ascorbic acid, and uric acid, were also evaluated, confirming the device's selectivity for lactate. The sensor fabricated demonstrated promising results for the quantitative measurement of lactate without requiring complex laboratory equipment, and it also showed great potential for further development in measuring other biomarkers in the human body."]},{"key":"dc:format","label":"Dc Format","values":["2588588","application/pdf"]},{"key":"dc:title","label":"Title","values":["A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique"]}]}],"canonical_facts":{"dc:contributor":["Taghipour, Fariborz"],"dc:creator":["Khodaei Tehrani, Ali"],"dc:date":["2024"],"dc:description":["Motivated by the growing need for lactate measurement in human biofluids, this study presents a novel fluorescent sensing device that is integrated with a commercial smartphone camera to analyze lactate concentrations. Highly fluorescent carbon quantum dots (CQDs) were chosen as the signal-generating element for the device, and these were modified by nitrogen doping and silica capping for a more robust performance. The molecularly imprinted polymer (MIP) technique was employed to create reception sites on the sensing layer and to provide the sensor with specificity toward lactate molecules. The synthesis was done using 3-aminopropyltriethoxysilane (APTES) as the functional monomer and tetraethyl silicate (TEOS) as the cross-linker to develop the sensor in the initial, liquid phase. Subsequently, the direct polymer deposition method was used to immobilize the sensing layer on small pieces of filter paper (sensing paper) and thus obtain a solid-phase sensor. The sensing papers were tested by exposure to varying lactate concentrations, ranging from 5 to 500 mM, in aqueous media, thus covering the full concentration range of lactate typically found in human sweat. A commercial smartphone camera was used to take photos of the sensing papers, and these photos were later analyzed against red-green-blue (RGB) and hue-saturation-lightness (HSL) color models. Linear correlations between the color values and the lactate concentrations were derived using their blue and saturation values. For concentrations below 100 mM, the blue values changed, showing a consistent pattern in relation to lactate concentrations; while for the higher concentrations of up to 500 mM, the saturation values changed, showing increasing sensitivity. According to the R² values obtained, both correlations were excellent fits with the data. The sensor responses to potentially interfering molecules, including glucose, ascorbic acid, and uric acid, were also evaluated, confirming the device's selectivity for lactate. The sensor fabricated demonstrated promising results for the quantitative measurement of lactate without requiring complex laboratory equipment, and it also showed great potential for further development in measuring other biomarkers in the human body."],"dc:format":["2588588","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/89410","http://circle.library.ubc.ca/bitstream/2429/89410/4/ubc_2024_november_khodaeitehrani_ali.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique"],"dc:type":["Text"],"thesis:degree_discipline":["Chemical and Biological Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:23Z"}