{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/89571"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/89571","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Construction of dual-beam optical tweezer for single-molecule study","abstract":"Optical tweezer is a well-established and continually evolved microscopic trapping and manipulation technique widely employed across numerous disciplines. A tightly focused Gaussian-profile laser can be used to confine homogenous particles by exerting two forces: 1. Scattering force, which maintains the target particles along the axis of the laser, and 2. Gradient forces prevent the particles from laterally drifting off the beam. We constructed a dual-beam variant of the optical tweezer for single-molecule studies. This system allows the simultaneous trapping of two particles, where one serves as an anchor point and the other moves to stretch DNA-based nanostructures. The decoupling from surface anchoring enables the system to achieve sub-piconewton resolution measurement with minimal environmental noise. We developed in-house programs facilitating data acquisition and control of various components. This allows rapid testing and deployment of custom features tailored for different experiment types and DNA structures. Finally, we established comprehensive user protocols and calibrated the system force measurement. The development of this instrument provides a powerful approach for future investigators in single molecular and cellular studies.","abstract_html":"Optical tweezer is a well-established and continually evolved microscopic trapping and manipulation technique widely employed across numerous disciplines. A tightly focused Gaussian-profile laser can be used to confine homogenous particles by exerting two forces: 1. Scattering force, which maintains the target particles along the axis of the laser, and 2. Gradient forces prevent the particles from laterally drifting off the beam. We constructed a dual-beam variant of the optical tweezer for single-molecule studies. This system allows the simultaneous trapping of two particles, where one serves as an anchor point and the other moves to stretch DNA-based nanostructures. The decoupling from surface anchoring enables the system to achieve sub-piconewton resolution measurement with minimal environmental noise. We developed in-house programs facilitating data acquisition and control of various components. This allows rapid testing and deployment of custom features tailored for different experiment types and DNA structures. Finally, we established comprehensive user protocols and calibrated the system force measurement. The development of this instrument provides a powerful approach for future investigators in single molecular and cellular studies.","abstract_has_math":false,"creators":["An, Minh (Scott)"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Biochemistry and Molecular Biology","degree_department":null,"school":null,"contributors":["Li, Isaac T. S."],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T15:14:25Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/89571","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/89571","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/89571/4/ubc_2025_february_an_minh.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F89571","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Li, Isaac T. S."]},{"key":"dc:creator","label":"Author","values":["An, Minh (Scott)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biochemistry and Molecular Biology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/89571","http://circle.library.ubc.ca/bitstream/2429/89571/4/ubc_2025_february_an_minh.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Optical tweezer is a well-established and continually evolved microscopic trapping and manipulation technique widely employed across numerous disciplines. A tightly focused Gaussian-profile laser can be used to confine homogenous particles by exerting two forces: 1. Scattering force, which maintains the target particles along the axis of the laser, and 2. Gradient forces prevent the particles from laterally drifting off the beam. We constructed a dual-beam variant of the optical tweezer for single-molecule studies. This system allows the simultaneous trapping of two particles, where one serves as an anchor point and the other moves to stretch DNA-based nanostructures. The decoupling from surface anchoring enables the system to achieve sub-piconewton resolution measurement with minimal environmental noise. We developed in-house programs facilitating data acquisition and control of various components. This allows rapid testing and deployment of custom features tailored for different experiment types and DNA structures. Finally, we established comprehensive user protocols and calibrated the system force measurement. The development of this instrument provides a powerful approach for future investigators in single molecular and cellular studies."]},{"key":"dc:format","label":"Dc Format","values":["64944701","application/pdf"]},{"key":"dc:title","label":"Title","values":["Construction of dual-beam optical tweezer for single-molecule study"]}]}],"canonical_facts":{"dc:contributor":["Li, Isaac T. S."],"dc:creator":["An, Minh (Scott)"],"dc:date":["2024"],"dc:description":["Optical tweezer is a well-established and continually evolved microscopic trapping and manipulation technique widely employed across numerous disciplines. A tightly focused Gaussian-profile laser can be used to confine homogenous particles by exerting two forces: 1. Scattering force, which maintains the target particles along the axis of the laser, and 2. Gradient forces prevent the particles from laterally drifting off the beam. We constructed a dual-beam variant of the optical tweezer for single-molecule studies. This system allows the simultaneous trapping of two particles, where one serves as an anchor point and the other moves to stretch DNA-based nanostructures. The decoupling from surface anchoring enables the system to achieve sub-piconewton resolution measurement with minimal environmental noise. We developed in-house programs facilitating data acquisition and control of various components. This allows rapid testing and deployment of custom features tailored for different experiment types and DNA structures. Finally, we established comprehensive user protocols and calibrated the system force measurement. The development of this instrument provides a powerful approach for future investigators in single molecular and cellular studies."],"dc:format":["64944701","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/89571","http://circle.library.ubc.ca/bitstream/2429/89571/4/ubc_2025_february_an_minh.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Construction of dual-beam optical tweezer for single-molecule study"],"dc:type":["Text"],"thesis:degree_discipline":["Biochemistry and Molecular Biology"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:25Z"}