{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/89689"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/89689","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Upscaling very low-resolution chemiluminescence images for prediction of thermoacoustic source term using machine learning","abstract":"Thermoacoustic oscillations in combustors need to be monitored and mitigated as they directly impact efficiency and safety of land-based power generation systems. Monitoring the thermoacoustic oscillations requires acquisition of high-resolution flame chemiluminescence images, which is not readily available in industrial settings due to the lack of optical access to the combustor. To mitigate thermoacoustics, this thesis proposes using few sensors to produce low-resolution flame chemiluminescence images, which are then upscaled using machine learning to high-resolution flame chemiluminescence images. A multi-path convolutional upscaling neural network (NN) is proposed and used in the present study to upscale the low-resolution flame chemiluminescence images to high-resolution flame chemiluminescence images. The effectiveness of the proposed NN is validated using image similarity metrics, and comparisons are made with existing image upscaling NNs in the literature. The performance of our NN is further assessed for predicting high-resolution spatial thermoacoustic source term. The proposed NN achieved more accurate upscaling and spatial thermoacoustic source term calculation compared to previous works in the literature. As a result, the present study demonstrates the feasibility of real-time detailed monitoring of thermoacoustic oscillations in industrial applications using few sensors.","abstract_html":"Thermoacoustic oscillations in combustors need to be monitored and mitigated as they directly impact efficiency and safety of land-based power generation systems. Monitoring the thermoacoustic oscillations requires acquisition of high-resolution flame chemiluminescence images, which is not readily available in industrial settings due to the lack of optical access to the combustor. To mitigate thermoacoustics, this thesis proposes using few sensors to produce low-resolution flame chemiluminescence images, which are then upscaled using machine learning to high-resolution flame chemiluminescence images. A multi-path convolutional upscaling neural network (NN) is proposed and used in the present study to upscale the low-resolution flame chemiluminescence images to high-resolution flame chemiluminescence images. The effectiveness of the proposed NN is validated using image similarity metrics, and comparisons are made with existing image upscaling NNs in the literature. The performance of our NN is further assessed for predicting high-resolution spatial thermoacoustic source term. The proposed NN achieved more accurate upscaling and spatial thermoacoustic source term calculation compared to previous works in the literature. As a result, the present study demonstrates the feasibility of real-time detailed monitoring of thermoacoustic oscillations in industrial applications using few sensors.","abstract_has_math":false,"creators":["Atoom, Adam Izzeldeen"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Electrical Engineering","degree_department":null,"school":null,"contributors":["Chaaban, Anas","Kheirkhah, Sina"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T15:14:25Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/89689","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/89689","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/89689/4/ubc_2025_february_atoom_adam.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F89689","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chaaban, Anas","Kheirkhah, Sina"]},{"key":"dc:creator","label":"Author","values":["Atoom, Adam Izzeldeen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/89689","http://circle.library.ubc.ca/bitstream/2429/89689/4/ubc_2025_february_atoom_adam.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Thermoacoustic oscillations in combustors need to be monitored and mitigated as they directly impact efficiency and safety of land-based power generation systems. Monitoring the thermoacoustic oscillations requires acquisition of high-resolution flame chemiluminescence images, which is not readily available in industrial settings due to the lack of optical access to the combustor. To mitigate thermoacoustics, this thesis proposes using few sensors to produce low-resolution flame chemiluminescence images, which are then upscaled using machine learning to high-resolution flame chemiluminescence images. A multi-path convolutional upscaling neural network (NN) is proposed and used in the present study to upscale the low-resolution flame chemiluminescence images to high-resolution flame chemiluminescence images. The effectiveness of the proposed NN is validated using image similarity metrics, and comparisons are made with existing image upscaling NNs in the literature. The performance of our NN is further assessed for predicting high-resolution spatial thermoacoustic source term. The proposed NN achieved more accurate upscaling and spatial thermoacoustic source term calculation compared to previous works in the literature. As a result, the present study demonstrates the feasibility of real-time detailed monitoring of thermoacoustic oscillations in industrial applications using few sensors."]},{"key":"dc:format","label":"Dc Format","values":["4165519","application/pdf"]},{"key":"dc:title","label":"Title","values":["Upscaling very low-resolution chemiluminescence images for prediction of thermoacoustic source term using machine learning"]}]}],"canonical_facts":{"dc:contributor":["Chaaban, Anas","Kheirkhah, Sina"],"dc:creator":["Atoom, Adam Izzeldeen"],"dc:date":["2024"],"dc:description":["Thermoacoustic oscillations in combustors need to be monitored and mitigated as they directly impact efficiency and safety of land-based power generation systems. Monitoring the thermoacoustic oscillations requires acquisition of high-resolution flame chemiluminescence images, which is not readily available in industrial settings due to the lack of optical access to the combustor. To mitigate thermoacoustics, this thesis proposes using few sensors to produce low-resolution flame chemiluminescence images, which are then upscaled using machine learning to high-resolution flame chemiluminescence images. A multi-path convolutional upscaling neural network (NN) is proposed and used in the present study to upscale the low-resolution flame chemiluminescence images to high-resolution flame chemiluminescence images. The effectiveness of the proposed NN is validated using image similarity metrics, and comparisons are made with existing image upscaling NNs in the literature. The performance of our NN is further assessed for predicting high-resolution spatial thermoacoustic source term. The proposed NN achieved more accurate upscaling and spatial thermoacoustic source term calculation compared to previous works in the literature. As a result, the present study demonstrates the feasibility of real-time detailed monitoring of thermoacoustic oscillations in industrial applications using few sensors."],"dc:format":["4165519","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/89689","http://circle.library.ubc.ca/bitstream/2429/89689/4/ubc_2025_february_atoom_adam.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Upscaling very low-resolution chemiluminescence images for prediction of thermoacoustic source term using machine learning"],"dc:type":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:25Z"}