{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/91466"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/91466","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Electrode specific measurements in a proton exchange membrane water electrolysis cell under accelerated stress testing conditions","abstract":"Among potentially greener energy alternatives, hydrogen produced by water electrolysis has been shown to be a scalable and transportable energy carrier. Electrolysis systems will require improvements in efficiency and lifetime to be as economical as carbon-fueled production methods. The present work reports on the first in-situ measurements from a micro-platinum wire used in an electrolysis cell over 1000 hours of operation to collect continuous half-cell voltage measurements, half-cell polarization curves and half-cell electrochemical impedance spectra. This configuration utilizes the micro-platinum wire as a dynamic hydrogen reference electrode. These findings are combined with post-mortem imaging on critical components. The reference electrode measurements indicate that the anode voltage increase is primarily responsible for the full-cell degradation rate of 77 μV/hr. The half-cell electron impedance spectroscopy measurements and transmission electron microscopy images of the spent catalyst, showed changes to the surface of the cathode catalyst, albeit with little effect on the overall cell performance. Based on these findings, this thesis proposes pathways for future work to advance cell degradation research, and possible design improvements.","abstract_html":"Among potentially greener energy alternatives, hydrogen produced by water electrolysis has been shown to be a scalable and transportable energy carrier. Electrolysis systems will require improvements in efficiency and lifetime to be as economical as carbon-fueled production methods. The present work reports on the first in-situ measurements from a micro-platinum wire used in an electrolysis cell over 1000 hours of operation to collect continuous half-cell voltage measurements, half-cell polarization curves and half-cell electrochemical impedance spectra. This configuration utilizes the micro-platinum wire as a dynamic hydrogen reference electrode. These findings are combined with post-mortem imaging on critical components. The reference electrode measurements indicate that the anode voltage increase is primarily responsible for the full-cell degradation rate of 77 μV/hr. The half-cell electron impedance spectroscopy measurements and transmission electron microscopy images of the spent catalyst, showed changes to the surface of the cathode catalyst, albeit with little effect on the overall cell performance. Based on these findings, this thesis proposes pathways for future work to advance cell degradation research, and possible design improvements.","abstract_has_math":false,"creators":["McLeod, Alexander"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Mérida, Walter"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T15:14:51Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/91466","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/91466","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/91466/8/ubc_2025_november_mcleod_alexander.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F91466","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mérida, Walter"]},{"key":"dc:creator","label":"Author","values":["McLeod, Alexander"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/91466","http://circle.library.ubc.ca/bitstream/2429/91466/8/ubc_2025_november_mcleod_alexander.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Among potentially greener energy alternatives, hydrogen produced by water electrolysis has been shown to be a scalable and transportable energy carrier. Electrolysis systems will require improvements in efficiency and lifetime to be as economical as carbon-fueled production methods. The present work reports on the first in-situ measurements from a micro-platinum wire used in an electrolysis cell over 1000 hours of operation to collect continuous half-cell voltage measurements, half-cell polarization curves and half-cell electrochemical impedance spectra. This configuration utilizes the micro-platinum wire as a dynamic hydrogen reference electrode. These findings are combined with post-mortem imaging on critical components. The reference electrode measurements indicate that the anode voltage increase is primarily responsible for the full-cell degradation rate of 77 μV/hr. The half-cell electron impedance spectroscopy measurements and transmission electron microscopy images of the spent catalyst, showed changes to the surface of the cathode catalyst, albeit with little effect on the overall cell performance. Based on these findings, this thesis proposes pathways for future work to advance cell degradation research, and possible design improvements."]},{"key":"dc:format","label":"Dc Format","values":["3671587","application/pdf"]},{"key":"dc:title","label":"Title","values":["Electrode specific measurements in a proton exchange membrane water electrolysis cell under accelerated stress testing conditions"]}]}],"canonical_facts":{"dc:contributor":["Mérida, Walter"],"dc:creator":["McLeod, Alexander"],"dc:date":["2025"],"dc:description":["Among potentially greener energy alternatives, hydrogen produced by water electrolysis has been shown to be a scalable and transportable energy carrier. Electrolysis systems will require improvements in efficiency and lifetime to be as economical as carbon-fueled production methods. The present work reports on the first in-situ measurements from a micro-platinum wire used in an electrolysis cell over 1000 hours of operation to collect continuous half-cell voltage measurements, half-cell polarization curves and half-cell electrochemical impedance spectra. This configuration utilizes the micro-platinum wire as a dynamic hydrogen reference electrode. These findings are combined with post-mortem imaging on critical components. The reference electrode measurements indicate that the anode voltage increase is primarily responsible for the full-cell degradation rate of 77 μV/hr. The half-cell electron impedance spectroscopy measurements and transmission electron microscopy images of the spent catalyst, showed changes to the surface of the cathode catalyst, albeit with little effect on the overall cell performance. Based on these findings, this thesis proposes pathways for future work to advance cell degradation research, and possible design improvements."],"dc:format":["3671587","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/91466","http://circle.library.ubc.ca/bitstream/2429/91466/8/ubc_2025_november_mcleod_alexander.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Electrode specific measurements in a proton exchange membrane water electrolysis cell under accelerated stress testing conditions"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:14:51Z"}