{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/9292"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/9292","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"The relationship of the heart rate threshold to the ventilatory threshold in trained cyclists","abstract":"The purpose of this study was to assess the relationship of the heart rate threshold (HRT) to the ventilatory threshold (TVENT) in trained cyclists. Twenty-one endurance trained cyclists (mean ± SD values: age = 26.2 ± 5.6 years; weight = 76.2 ± 8.2 kg; height = 179.1 ± 6.3 cm; VO₂ max. = 67.6 ± 4.7 ml • kg • min⁻¹) volunteered to participate in this study. Each subject completed a maximal cycle ergometer test to volitional fatigue. The procedure utilized a ramped protocol on an electronically braked cycle ergometer with initial resistance set at 50 watts (W) • min⁻¹ with a 30 W • min⁻¹ increase. Ventilatory variables (VE, VO₂ , VCO₂ ) and power were measured on-line with averages reported every twenty seconds. Heart rate (HR) was measured using a portable cardio-telemetric monitor and was observer recorded every twenty seconds. TVENT was assessed using the excess CO₂ (ExCCh) elimination curve. The HRT was assessed using a mathematical model (MM) that incorporates the natural log of H R data points to produce a curvilinear fit through these points. The first order derivative of the upper portion of the logistic curve delineated the HRT. Statistical significance was set a priori at p < 0.01. Paired t-tests indicated that there were no significant differences (p > 0.01) between HR values at HRT (171.7 ± 9.6 beats • min⁻¹) and TVENT (169.8 ± 9.9 beats • min⁻¹) or VO₂ values at HRT (53.6 ± 4.2 ml • kg • min⁻¹ ') and TVENT (52.2. ± 4.8 ml • kg • min\"1). However, power values at HRT (318.7 ± 30.7 W) were significantly different from those at TVENT (334.8 ± 36.7 W). Pearson product-moment zero-order correlation coefficient demonstrated significant relationships between HRT and T V E N T for the physiological variables of H R (r = 0.92, p < 0.001), VO₂ (r = 0.72, p < 0.001) and power (r = 0.77, p < 0.001). These findings indicate that H R and VO₂ at the HRT are not significantly different from those values at TVENT in trained cyclists.","abstract_html":"The purpose of this study was to assess the relationship of the heart rate threshold (HRT) to the ventilatory threshold (TVENT) in trained cyclists. Twenty-one endurance trained cyclists (mean ± SD values: age = 26.2 ± 5.6 years; weight = 76.2 ± 8.2 kg; height = 179.1 ± 6.3 cm; VO₂ max. = 67.6 ± 4.7 ml • kg • min⁻¹) volunteered to participate in this study. Each subject completed a maximal cycle ergometer test to volitional fatigue. The procedure utilized a ramped protocol on an electronically braked cycle ergometer with initial resistance set at 50 watts (W) • min⁻¹ with a 30 W • min⁻¹ increase. Ventilatory variables (VE, VO₂ , VCO₂ ) and power were measured on-line with averages reported every twenty seconds. Heart rate (HR) was measured using a portable cardio-telemetric monitor and was observer recorded every twenty seconds. TVENT was assessed using the excess CO₂ (ExCCh) elimination curve. The HRT was assessed using a mathematical model (MM) that incorporates the natural log of H R data points to produce a curvilinear fit through these points. The first order derivative of the upper portion of the logistic curve delineated the HRT. Statistical significance was set a priori at p &lt; 0.01. Paired t-tests indicated that there were no significant differences (p &gt; 0.01) between HR values at HRT (171.7 ± 9.6 beats • min⁻¹) and TVENT (169.8 ± 9.9 beats • min⁻¹) or VO₂ values at HRT (53.6 ± 4.2 ml • kg • min⁻¹ &#x27;) and TVENT (52.2. ± 4.8 ml • kg • min&quot;1). However, power values at HRT (318.7 ± 30.7 W) were significantly different from those at TVENT (334.8 ± 36.7 W). Pearson product-moment zero-order correlation coefficient demonstrated significant relationships between HRT and T V E N T for the physiological variables of H R (r = 0.92, p &lt; 0.001), VO₂ (r = 0.72, p &lt; 0.001) and power (r = 0.77, p &lt; 0.001). These findings indicate that H R and VO₂ at the HRT are not significantly different from those values at TVENT in trained cyclists.","abstract_has_math":false,"creators":["Bodner, Michael Eugene"],"institution":"University of British Columbia","degree_name":"Master of Science - MSc","degree_level":"master's","degree_discipline":"Human Kinetics","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1999,"date_issued":"1999","date_published":"1999","updated_at":"2026-11-19T14:28:00Z","subjects":[],"languages":["eng"],"rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/9292","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/9292","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/9292/1/ubc_1999-0403.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F9292","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Bodner, Michael Eugene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1999"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Human Kinetics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science - MSc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/9292","http://circle.library.ubc.ca/bitstream/2429/9292/1/ubc_1999-0403.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["The purpose of this study was to assess the relationship of the heart rate threshold (HRT) to the ventilatory threshold (TVENT) in trained cyclists. Twenty-one endurance trained cyclists (mean ± SD values: age = 26.2 ± 5.6 years; weight = 76.2 ± 8.2 kg; height = 179.1 ± 6.3 cm; VO₂ max. = 67.6 ± 4.7 ml • kg • min⁻¹) volunteered to participate in this study. Each subject completed a maximal cycle ergometer test to volitional fatigue. The procedure utilized a ramped protocol on an electronically braked cycle ergometer with initial resistance set at 50 watts (W) • min⁻¹ with a 30 W • min⁻¹ increase. Ventilatory variables (VE, VO₂ , VCO₂ ) and power were measured on-line with averages reported every twenty seconds. Heart rate (HR) was measured using a portable cardio-telemetric monitor and was observer recorded every twenty seconds. TVENT was assessed using the excess CO₂ (ExCCh) elimination curve. The HRT was assessed using a mathematical model (MM) that incorporates the natural log of H R data points to produce a curvilinear fit through these points. The first order derivative of the upper portion of the logistic curve delineated the HRT. Statistical significance was set a priori at p < 0.01. Paired t-tests indicated that there were no significant differences (p > 0.01) between HR values at HRT (171.7 ± 9.6 beats • min⁻¹) and TVENT (169.8 ± 9.9 beats • min⁻¹) or VO₂ values at HRT (53.6 ± 4.2 ml • kg • min⁻¹ ') and TVENT (52.2. ± 4.8 ml • kg • min\"1). However, power values at HRT (318.7 ± 30.7 W) were significantly different from those at TVENT (334.8 ± 36.7 W). Pearson product-moment zero-order correlation coefficient demonstrated significant relationships between HRT and T V E N T for the physiological variables of H R (r = 0.92, p < 0.001), VO₂ (r = 0.72, p < 0.001) and power (r = 0.77, p < 0.001). These findings indicate that H R and VO₂ at the HRT are not significantly different from those values at TVENT in trained cyclists."]},{"key":"dc:format","label":"Dc Format","values":["3909194","application/pdf"]},{"key":"dc:title","label":"Title","values":["The relationship of the heart rate threshold to the ventilatory threshold in trained cyclists"]}]}],"canonical_facts":{"dc:creator":["Bodner, Michael Eugene"],"dc:date":["1999"],"dc:description":["The purpose of this study was to assess the relationship of the heart rate threshold (HRT) to the ventilatory threshold (TVENT) in trained cyclists. Twenty-one endurance trained cyclists (mean ± SD values: age = 26.2 ± 5.6 years; weight = 76.2 ± 8.2 kg; height = 179.1 ± 6.3 cm; VO₂ max. = 67.6 ± 4.7 ml • kg • min⁻¹) volunteered to participate in this study. Each subject completed a maximal cycle ergometer test to volitional fatigue. The procedure utilized a ramped protocol on an electronically braked cycle ergometer with initial resistance set at 50 watts (W) • min⁻¹ with a 30 W • min⁻¹ increase. Ventilatory variables (VE, VO₂ , VCO₂ ) and power were measured on-line with averages reported every twenty seconds. Heart rate (HR) was measured using a portable cardio-telemetric monitor and was observer recorded every twenty seconds. TVENT was assessed using the excess CO₂ (ExCCh) elimination curve. The HRT was assessed using a mathematical model (MM) that incorporates the natural log of H R data points to produce a curvilinear fit through these points. The first order derivative of the upper portion of the logistic curve delineated the HRT. Statistical significance was set a priori at p < 0.01. Paired t-tests indicated that there were no significant differences (p > 0.01) between HR values at HRT (171.7 ± 9.6 beats • min⁻¹) and TVENT (169.8 ± 9.9 beats • min⁻¹) or VO₂ values at HRT (53.6 ± 4.2 ml • kg • min⁻¹ ') and TVENT (52.2. ± 4.8 ml • kg • min\"1). However, power values at HRT (318.7 ± 30.7 W) were significantly different from those at TVENT (334.8 ± 36.7 W). Pearson product-moment zero-order correlation coefficient demonstrated significant relationships between HRT and T V E N T for the physiological variables of H R (r = 0.92, p < 0.001), VO₂ (r = 0.72, p < 0.001) and power (r = 0.77, p < 0.001). These findings indicate that H R and VO₂ at the HRT are not significantly different from those values at TVENT in trained cyclists."],"dc:format":["3909194","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/9292","http://circle.library.ubc.ca/bitstream/2429/9292/1/ubc_1999-0403.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use."],"dc:title":["The relationship of the heart rate threshold to the ventilatory threshold in trained cyclists"],"dc:type":["Text"],"thesis:degree_discipline":["Human Kinetics"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Science - MSc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T14:28:00Z"}