{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/93922"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/93922","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Decision-level sensor fusion for a placement adaptable near-fall and fall detection system","abstract":"Occupational slips, trips, and falls on the same level remain a major source of workplace injury. Wearable inertial measurement unit (IMU) sensors have been proposed for near-fall and fall detection, but many systems are sensitive to sensor placement and may not generalize well beyond controlled laboratory settings. This thesis evaluates a placement-adaptable near-fall and fall detection model in real-world occupational environments and extends it using decision-level sensor fusion. A total of 510 hours of data were collected from 30 adults (20 female, 10 male; age 26.8 ± 3.9 years) wearing the sensors on their lower back and both thighs. A total of 4 near-falls and 1 fall were reported. Due to extreme class imbalance, evaluation focused on activities of daily living (ADLs) and false positive fall and near-fall detections, where ADLs were incorrectly classified as events. Individual sensors achieved 97.21% ADL specificity but produced 36.07 near-fall and 0.98 fall false alarms per hour, with thigh sensors generating the highest false-positive rates. Decision-level fusion reduced false positives across sensors. Using three sensors, unanimous voting achieved 99.90% ADL specificity with 0.50 near-fall and 0 fall false alarms per hour, but required full agreement across sensors, reducing decision coverage. Majority voting achieved 98.47% ADL specificity with 7.60 near-fall and 0.05 fall false alarms per hour, but required all three sensors to be available to determine a majority, reducing robustness to sensor failure and user preferences. In contrast, Bayesian fusion maintained full decision coverage and reduced uncertainty from individual sensor predictions by 85.6%, enabling a measurable reduction in classification ambiguity while achieving 98.89% ADL specificity with 5.55 near-fall and 0.05 fall false alarms per hour. These findings demonstrate that decision-level Bayesian fusion improves reliability by reducing uncertainty and false positives in real-world occupational data without retraining the base models. While individual-level alerting remains limited by false positives, the framework enables population-level monitoring and establishes a scalable foundation for future occupational near-fall and fall risk assessment with larger datasets.","abstract_html":"Occupational slips, trips, and falls on the same level remain a major source of workplace injury. Wearable inertial measurement unit (IMU) sensors have been proposed for near-fall and fall detection, but many systems are sensitive to sensor placement and may not generalize well beyond controlled laboratory settings. This thesis evaluates a placement-adaptable near-fall and fall detection model in real-world occupational environments and extends it using decision-level sensor fusion. A total of 510 hours of data were collected from 30 adults (20 female, 10 male; age 26.8 ± 3.9 years) wearing the sensors on their lower back and both thighs. A total of 4 near-falls and 1 fall were reported. Due to extreme class imbalance, evaluation focused on activities of daily living (ADLs) and false positive fall and near-fall detections, where ADLs were incorrectly classified as events. Individual sensors achieved 97.21% ADL specificity but produced 36.07 near-fall and 0.98 fall false alarms per hour, with thigh sensors generating the highest false-positive rates. Decision-level fusion reduced false positives across sensors. Using three sensors, unanimous voting achieved 99.90% ADL specificity with 0.50 near-fall and 0 fall false alarms per hour, but required full agreement across sensors, reducing decision coverage. Majority voting achieved 98.47% ADL specificity with 7.60 near-fall and 0.05 fall false alarms per hour, but required all three sensors to be available to determine a majority, reducing robustness to sensor failure and user preferences. In contrast, Bayesian fusion maintained full decision coverage and reduced uncertainty from individual sensor predictions by 85.6%, enabling a measurable reduction in classification ambiguity while achieving 98.89% ADL specificity with 5.55 near-fall and 0.05 fall false alarms per hour. These findings demonstrate that decision-level Bayesian fusion improves reliability by reducing uncertainty and false positives in real-world occupational data without retraining the base models. While individual-level alerting remains limited by false positives, the framework enables population-level monitoring and establishes a scalable foundation for future occupational near-fall and fall risk assessment with larger datasets.","abstract_has_math":false,"creators":["Gumbe, Rael"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":["Kuo, Calvin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T15:15:16Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/93922","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/93922","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/93922/6/ubc_2026_may_gumbe_rael.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F93922","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kuo, Calvin"]},{"key":"dc:creator","label":"Author","values":["Gumbe, Rael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/93922","http://circle.library.ubc.ca/bitstream/2429/93922/6/ubc_2026_may_gumbe_rael.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Occupational slips, trips, and falls on the same level remain a major source of workplace injury. Wearable inertial measurement unit (IMU) sensors have been proposed for near-fall and fall detection, but many systems are sensitive to sensor placement and may not generalize well beyond controlled laboratory settings. This thesis evaluates a placement-adaptable near-fall and fall detection model in real-world occupational environments and extends it using decision-level sensor fusion. A total of 510 hours of data were collected from 30 adults (20 female, 10 male; age 26.8 ± 3.9 years) wearing the sensors on their lower back and both thighs. A total of 4 near-falls and 1 fall were reported. Due to extreme class imbalance, evaluation focused on activities of daily living (ADLs) and false positive fall and near-fall detections, where ADLs were incorrectly classified as events. Individual sensors achieved 97.21% ADL specificity but produced 36.07 near-fall and 0.98 fall false alarms per hour, with thigh sensors generating the highest false-positive rates. Decision-level fusion reduced false positives across sensors. Using three sensors, unanimous voting achieved 99.90% ADL specificity with 0.50 near-fall and 0 fall false alarms per hour, but required full agreement across sensors, reducing decision coverage. Majority voting achieved 98.47% ADL specificity with 7.60 near-fall and 0.05 fall false alarms per hour, but required all three sensors to be available to determine a majority, reducing robustness to sensor failure and user preferences. In contrast, Bayesian fusion maintained full decision coverage and reduced uncertainty from individual sensor predictions by 85.6%, enabling a measurable reduction in classification ambiguity while achieving 98.89% ADL specificity with 5.55 near-fall and 0.05 fall false alarms per hour. These findings demonstrate that decision-level Bayesian fusion improves reliability by reducing uncertainty and false positives in real-world occupational data without retraining the base models. While individual-level alerting remains limited by false positives, the framework enables population-level monitoring and establishes a scalable foundation for future occupational near-fall and fall risk assessment with larger datasets."]},{"key":"dc:format","label":"Dc Format","values":["2279183","application/pdf"]},{"key":"dc:title","label":"Title","values":["Decision-level sensor fusion for a placement adaptable near-fall and fall detection system"]}]}],"canonical_facts":{"dc:contributor":["Kuo, Calvin"],"dc:creator":["Gumbe, Rael"],"dc:date":["2026"],"dc:description":["Occupational slips, trips, and falls on the same level remain a major source of workplace injury. Wearable inertial measurement unit (IMU) sensors have been proposed for near-fall and fall detection, but many systems are sensitive to sensor placement and may not generalize well beyond controlled laboratory settings. This thesis evaluates a placement-adaptable near-fall and fall detection model in real-world occupational environments and extends it using decision-level sensor fusion. A total of 510 hours of data were collected from 30 adults (20 female, 10 male; age 26.8 ± 3.9 years) wearing the sensors on their lower back and both thighs. A total of 4 near-falls and 1 fall were reported. Due to extreme class imbalance, evaluation focused on activities of daily living (ADLs) and false positive fall and near-fall detections, where ADLs were incorrectly classified as events. Individual sensors achieved 97.21% ADL specificity but produced 36.07 near-fall and 0.98 fall false alarms per hour, with thigh sensors generating the highest false-positive rates. Decision-level fusion reduced false positives across sensors. Using three sensors, unanimous voting achieved 99.90% ADL specificity with 0.50 near-fall and 0 fall false alarms per hour, but required full agreement across sensors, reducing decision coverage. Majority voting achieved 98.47% ADL specificity with 7.60 near-fall and 0.05 fall false alarms per hour, but required all three sensors to be available to determine a majority, reducing robustness to sensor failure and user preferences. In contrast, Bayesian fusion maintained full decision coverage and reduced uncertainty from individual sensor predictions by 85.6%, enabling a measurable reduction in classification ambiguity while achieving 98.89% ADL specificity with 5.55 near-fall and 0.05 fall false alarms per hour. These findings demonstrate that decision-level Bayesian fusion improves reliability by reducing uncertainty and false positives in real-world occupational data without retraining the base models. While individual-level alerting remains limited by false positives, the framework enables population-level monitoring and establishes a scalable foundation for future occupational near-fall and fall risk assessment with larger datasets."],"dc:format":["2279183","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/93922","http://circle.library.ubc.ca/bitstream/2429/93922/6/ubc_2026_may_gumbe_rael.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Decision-level sensor fusion for a placement adaptable near-fall and fall detection system"],"dc:type":["Text"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:15:16Z"}