{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/94202"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/94202","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Pulse sequence design for fast and flexible sodium magnetic resonance imaging","abstract":"Sodium (²³Na) magnetic resonance imaging can be used to obtain information that is complementary to that of routine clinical hydrogen (¹H) MRI. Imaging ²³Na is challenging due to its low in-vivo signal-to-noise ratio and rapid transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min per slice. This dissertation explores the design of two novel pulse sequences that combine simultaneous multi-slice and UTE techniques to reduce scan times for ²³Na MRI: (1) The power independent of number of slices presaturated UTE (PINS-UTE) sequence uses a prepulse to saturate wide regions of magnetization and a non-selective pulse to simultaneously excite three slices; (2) The differential multi-block presaturated UTE (δMB-UTE) uses a prepulse to saturate two blocks of magnetization and a non-selective pulse to excite the surrounding magnetization. By subtracting acquisitions with shifted saturation blocks, four simultaneous slices are imaged. Both sequences are first implemented for ¹H MRI, then modified for ²³Na MRI. The δMB-UTE sequence enabled the rapid imaging of a reduced through-plane field-of-view (FOV) with both ¹H and ²³Na MRI. Images obtained with the PINS-UTE sequence exhibited signal variation due to unwanted signal between the slices. When acquiring ²³Na images with the same FOV, resolution, and repetition time, the scan times required by the PINS-UTE and δMB-UTE sequences are expected to be reduced by a factor of 12 as compared to 2D UTE sequences. Compared to similarly matched 3D UTE sequences, the scan time of the PINS-UTE sequence is expected to be increased by a factor of 1.75, while the scan time of the δMB-UTE sequence is expected to be comparable. For both sequences, greater acceleration relative to 3D UTE sequences may be achieved when fewer slices are imaged or when high in-plane resolution is desired. The sequences introduced in this dissertation may enable the integration of ²³Na MRI into clinical protocols and support studies of diseases such as multiple sclerosis, stroke, and cancer.","abstract_html":"Sodium (²³Na) magnetic resonance imaging can be used to obtain information that is complementary to that of routine clinical hydrogen (¹H) MRI. Imaging ²³Na is challenging due to its low in-vivo signal-to-noise ratio and rapid transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min per slice. This dissertation explores the design of two novel pulse sequences that combine simultaneous multi-slice and UTE techniques to reduce scan times for ²³Na MRI: (1) The power independent of number of slices presaturated UTE (PINS-UTE) sequence uses a prepulse to saturate wide regions of magnetization and a non-selective pulse to simultaneously excite three slices; (2) The differential multi-block presaturated UTE (δMB-UTE) uses a prepulse to saturate two blocks of magnetization and a non-selective pulse to excite the surrounding magnetization. By subtracting acquisitions with shifted saturation blocks, four simultaneous slices are imaged. Both sequences are first implemented for ¹H MRI, then modified for ²³Na MRI. The δMB-UTE sequence enabled the rapid imaging of a reduced through-plane field-of-view (FOV) with both ¹H and ²³Na MRI. Images obtained with the PINS-UTE sequence exhibited signal variation due to unwanted signal between the slices. When acquiring ²³Na images with the same FOV, resolution, and repetition time, the scan times required by the PINS-UTE and δMB-UTE sequences are expected to be reduced by a factor of 12 as compared to 2D UTE sequences. Compared to similarly matched 3D UTE sequences, the scan time of the PINS-UTE sequence is expected to be increased by a factor of 1.75, while the scan time of the δMB-UTE sequence is expected to be comparable. For both sequences, greater acceleration relative to 3D UTE sequences may be achieved when fewer slices are imaged or when high in-plane resolution is desired. The sequences introduced in this dissertation may enable the integration of ²³Na MRI into clinical protocols and support studies of diseases such as multiple sclerosis, stroke, and cancer.","abstract_has_math":false,"creators":["Reich, Jason Andrew"],"institution":"University of British Columbia","degree_name":"Doctor of Philosophy - PhD","degree_level":"doctoral","degree_discipline":"Medical Physics","degree_department":null,"school":null,"contributors":["Feldman, Rebecca"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T15:15:21Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/94202","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/94202","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/94202/4/ubc_2026_may_reich_jason.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F94202","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Feldman, Rebecca"]},{"key":"dc:creator","label":"Author","values":["Reich, Jason Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Physics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy - PhD"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/94202","http://circle.library.ubc.ca/bitstream/2429/94202/4/ubc_2026_may_reich_jason.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Sodium (²³Na) magnetic resonance imaging can be used to obtain information that is complementary to that of routine clinical hydrogen (¹H) MRI. Imaging ²³Na is challenging due to its low in-vivo signal-to-noise ratio and rapid transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min per slice. This dissertation explores the design of two novel pulse sequences that combine simultaneous multi-slice and UTE techniques to reduce scan times for ²³Na MRI: (1) The power independent of number of slices presaturated UTE (PINS-UTE) sequence uses a prepulse to saturate wide regions of magnetization and a non-selective pulse to simultaneously excite three slices; (2) The differential multi-block presaturated UTE (δMB-UTE) uses a prepulse to saturate two blocks of magnetization and a non-selective pulse to excite the surrounding magnetization. By subtracting acquisitions with shifted saturation blocks, four simultaneous slices are imaged. Both sequences are first implemented for ¹H MRI, then modified for ²³Na MRI. The δMB-UTE sequence enabled the rapid imaging of a reduced through-plane field-of-view (FOV) with both ¹H and ²³Na MRI. Images obtained with the PINS-UTE sequence exhibited signal variation due to unwanted signal between the slices. When acquiring ²³Na images with the same FOV, resolution, and repetition time, the scan times required by the PINS-UTE and δMB-UTE sequences are expected to be reduced by a factor of 12 as compared to 2D UTE sequences. Compared to similarly matched 3D UTE sequences, the scan time of the PINS-UTE sequence is expected to be increased by a factor of 1.75, while the scan time of the δMB-UTE sequence is expected to be comparable. For both sequences, greater acceleration relative to 3D UTE sequences may be achieved when fewer slices are imaged or when high in-plane resolution is desired. The sequences introduced in this dissertation may enable the integration of ²³Na MRI into clinical protocols and support studies of diseases such as multiple sclerosis, stroke, and cancer."]},{"key":"dc:format","label":"Dc Format","values":["12558468","application/pdf"]},{"key":"dc:title","label":"Title","values":["Pulse sequence design for fast and flexible sodium magnetic resonance imaging"]}]}],"canonical_facts":{"dc:contributor":["Feldman, Rebecca"],"dc:creator":["Reich, Jason Andrew"],"dc:date":["2026"],"dc:description":["Sodium (²³Na) magnetic resonance imaging can be used to obtain information that is complementary to that of routine clinical hydrogen (¹H) MRI. Imaging ²³Na is challenging due to its low in-vivo signal-to-noise ratio and rapid transverse relaxation. Three-dimensional (3D) ultrashort echo time (UTE) sequences, often used for ²³Na MRI, involve whole-volume acquisitions that require scan times of 10–34 min. Two-dimensional (2D) UTE sequences can be used to image a reduced number of slices, but scan times range 8–10 min per slice. This dissertation explores the design of two novel pulse sequences that combine simultaneous multi-slice and UTE techniques to reduce scan times for ²³Na MRI: (1) The power independent of number of slices presaturated UTE (PINS-UTE) sequence uses a prepulse to saturate wide regions of magnetization and a non-selective pulse to simultaneously excite three slices; (2) The differential multi-block presaturated UTE (δMB-UTE) uses a prepulse to saturate two blocks of magnetization and a non-selective pulse to excite the surrounding magnetization. By subtracting acquisitions with shifted saturation blocks, four simultaneous slices are imaged. Both sequences are first implemented for ¹H MRI, then modified for ²³Na MRI. The δMB-UTE sequence enabled the rapid imaging of a reduced through-plane field-of-view (FOV) with both ¹H and ²³Na MRI. Images obtained with the PINS-UTE sequence exhibited signal variation due to unwanted signal between the slices. When acquiring ²³Na images with the same FOV, resolution, and repetition time, the scan times required by the PINS-UTE and δMB-UTE sequences are expected to be reduced by a factor of 12 as compared to 2D UTE sequences. Compared to similarly matched 3D UTE sequences, the scan time of the PINS-UTE sequence is expected to be increased by a factor of 1.75, while the scan time of the δMB-UTE sequence is expected to be comparable. For both sequences, greater acceleration relative to 3D UTE sequences may be achieved when fewer slices are imaged or when high in-plane resolution is desired. The sequences introduced in this dissertation may enable the integration of ²³Na MRI into clinical protocols and support studies of diseases such as multiple sclerosis, stroke, and cancer."],"dc:format":["12558468","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/94202","http://circle.library.ubc.ca/bitstream/2429/94202/4/ubc_2026_may_reich_jason.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["http://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Pulse sequence design for fast and flexible sodium magnetic resonance imaging"],"dc:type":["Text"],"thesis:degree_discipline":["Medical Physics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy - PhD"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:15:21Z"}