{"id":{"repo_id":"ubc","oai_identifier":"oai:circle.library.ubc.ca:2429/95450"},"canonical_url":"https://search.ndltd.org/etd/ubc/oai:circle.library.ubc.ca:2429/95450","repository":{"repo_id":"ubc","name":"University of British Columbia","base_url":"http://circle.library.ubc.ca/oai/request"},"display":{"title":"Redundancy-aware hybrid FE–analytical compliance modeling and experimental assessment of a 3-(P-P)PPSR hybrid parallel robot","abstract":"Kinematic isotropy alone is insufficient to characterise the load-induced motion of a redundantly actuated parallel robot. This thesis develops a hybrid FE–analytical compliance model for the 3-(P-P)PPSR hybrid parallel robot. A redundancy-dependent analytical baseline first quantifies actuator stiffness and actuator-error transmission. Precomputed single-leg compliance matrices at 15 poses then describe the position-dependent gantry response. The formulation adds active-axis compliance in each leg’s physical local frame, represents the SR-link and passive joints analytically, and assembles the three legs using work-conjugate transformations and Schur condensation. The model is assessed fully a priori against loaded and unloaded FARO laser-tracker measurements at 17 matched poses under a 4.55 kg load. The actuator-only baseline gives a platform translation-vector RMSE of 0.73 mm; adding the distributed structural compliance reduces it to 0.36 mm. The corresponding mapped gantry-marker predictions achieve an RMSE of 0.15 mm. The comparison uses no fitted compliance parameter or bias correction. Within the evaluated ranges, the Zaber transverse-stiffness and load-hook offset studies change the predicted translation by at most 1.93% and 2.07%, respectively. The improvement over the actuator-only baseline shows that the distributed gantry, SR-link, passive-joint, and three-leg assembly compliance is essential to the measured gravity response. A systematic platform residual remains and defines a quantitative target for model updating. The framework’s principal value is its modular, physically consistent connection of pose-dependent single-leg FE compliance to whole-robot response. The surrogate and analytical assembly reuse the FE database to predict platform and measurement-point response without a new FE solve at every pose. The framework supports stiffness-aware configuration assessment, sensitivity analysis, experimental design, and future model updating. The 17-pose comparison establishes a quantitative baseline that subsequent refinements must exceed.","abstract_html":"Kinematic isotropy alone is insufficient to characterise the load-induced motion of a redundantly actuated parallel robot. This thesis develops a hybrid FE–analytical compliance model for the 3-(P-P)PPSR hybrid parallel robot. A redundancy-dependent analytical baseline first quantifies actuator stiffness and actuator-error transmission. Precomputed single-leg compliance matrices at 15 poses then describe the position-dependent gantry response. The formulation adds active-axis compliance in each leg’s physical local frame, represents the SR-link and passive joints analytically, and assembles the three legs using work-conjugate transformations and Schur condensation. The model is assessed fully a priori against loaded and unloaded FARO laser-tracker measurements at 17 matched poses under a 4.55 kg load. The actuator-only baseline gives a platform translation-vector RMSE of 0.73 mm; adding the distributed structural compliance reduces it to 0.36 mm. The corresponding mapped gantry-marker predictions achieve an RMSE of 0.15 mm. The comparison uses no fitted compliance parameter or bias correction. Within the evaluated ranges, the Zaber transverse-stiffness and load-hook offset studies change the predicted translation by at most 1.93% and 2.07%, respectively. The improvement over the actuator-only baseline shows that the distributed gantry, SR-link, passive-joint, and three-leg assembly compliance is essential to the measured gravity response. A systematic platform residual remains and defines a quantitative target for model updating. The framework’s principal value is its modular, physically consistent connection of pose-dependent single-leg FE compliance to whole-robot response. The surrogate and analytical assembly reuse the FE database to predict platform and measurement-point response without a new FE solve at every pose. The framework supports stiffness-aware configuration assessment, sensitivity analysis, experimental design, and future model updating. The 17-pose comparison establishes a quantitative baseline that subsequent refinements must exceed.","abstract_has_math":false,"creators":["Ma, Qide"],"institution":"University of British Columbia","degree_name":"Master of Applied Science - MASc","degree_level":"master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":["Wen, Kefei"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T15:15:36Z","subjects":[],"languages":["eng"],"rights":["Attribution-NonCommercial-NoDerivatives 4.0 International"],"rights_urls":["https://creativecommons.org/licenses/by-nc-nd/4.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/2429/95450","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/2429/95450","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":"http://circle.library.ubc.ca/bitstream/2429/95450/5/ubc_2026_november_ma_qide.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"http://circle.library.ubc.ca/oai/request?verb=GetRecord&metadataPrefix=etdms&identifier=oai%3Acircle.library.ubc.ca%3A2429%2F95450","prefix":"etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wen, Kefei"]},{"key":"dc:creator","label":"Author","values":["Ma, Qide"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["University of British Columbia"]},{"key":"dc:type","label":"Dc Type","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Science - MASc"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of British Columbia"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["https://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/2429/95450","http://circle.library.ubc.ca/bitstream/2429/95450/5/ubc_2026_november_ma_qide.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Kinematic isotropy alone is insufficient to characterise the load-induced motion of a redundantly actuated parallel robot. This thesis develops a hybrid FE–analytical compliance model for the 3-(P-P)PPSR hybrid parallel robot. A redundancy-dependent analytical baseline first quantifies actuator stiffness and actuator-error transmission. Precomputed single-leg compliance matrices at 15 poses then describe the position-dependent gantry response. The formulation adds active-axis compliance in each leg’s physical local frame, represents the SR-link and passive joints analytically, and assembles the three legs using work-conjugate transformations and Schur condensation. The model is assessed fully a priori against loaded and unloaded FARO laser-tracker measurements at 17 matched poses under a 4.55 kg load. The actuator-only baseline gives a platform translation-vector RMSE of 0.73 mm; adding the distributed structural compliance reduces it to 0.36 mm. The corresponding mapped gantry-marker predictions achieve an RMSE of 0.15 mm. The comparison uses no fitted compliance parameter or bias correction. Within the evaluated ranges, the Zaber transverse-stiffness and load-hook offset studies change the predicted translation by at most 1.93% and 2.07%, respectively. The improvement over the actuator-only baseline shows that the distributed gantry, SR-link, passive-joint, and three-leg assembly compliance is essential to the measured gravity response. A systematic platform residual remains and defines a quantitative target for model updating. The framework’s principal value is its modular, physically consistent connection of pose-dependent single-leg FE compliance to whole-robot response. The surrogate and analytical assembly reuse the FE database to predict platform and measurement-point response without a new FE solve at every pose. The framework supports stiffness-aware configuration assessment, sensitivity analysis, experimental design, and future model updating. The 17-pose comparison establishes a quantitative baseline that subsequent refinements must exceed."]},{"key":"dc:format","label":"Dc Format","values":["4399667","application/pdf"]},{"key":"dc:title","label":"Title","values":["Redundancy-aware hybrid FE–analytical compliance modeling and experimental assessment of a 3-(P-P)PPSR hybrid parallel robot"]}]}],"canonical_facts":{"dc:contributor":["Wen, Kefei"],"dc:creator":["Ma, Qide"],"dc:date":["2026"],"dc:description":["Kinematic isotropy alone is insufficient to characterise the load-induced motion of a redundantly actuated parallel robot. This thesis develops a hybrid FE–analytical compliance model for the 3-(P-P)PPSR hybrid parallel robot. A redundancy-dependent analytical baseline first quantifies actuator stiffness and actuator-error transmission. Precomputed single-leg compliance matrices at 15 poses then describe the position-dependent gantry response. The formulation adds active-axis compliance in each leg’s physical local frame, represents the SR-link and passive joints analytically, and assembles the three legs using work-conjugate transformations and Schur condensation. The model is assessed fully a priori against loaded and unloaded FARO laser-tracker measurements at 17 matched poses under a 4.55 kg load. The actuator-only baseline gives a platform translation-vector RMSE of 0.73 mm; adding the distributed structural compliance reduces it to 0.36 mm. The corresponding mapped gantry-marker predictions achieve an RMSE of 0.15 mm. The comparison uses no fitted compliance parameter or bias correction. Within the evaluated ranges, the Zaber transverse-stiffness and load-hook offset studies change the predicted translation by at most 1.93% and 2.07%, respectively. The improvement over the actuator-only baseline shows that the distributed gantry, SR-link, passive-joint, and three-leg assembly compliance is essential to the measured gravity response. A systematic platform residual remains and defines a quantitative target for model updating. The framework’s principal value is its modular, physically consistent connection of pose-dependent single-leg FE compliance to whole-robot response. The surrogate and analytical assembly reuse the FE database to predict platform and measurement-point response without a new FE solve at every pose. The framework supports stiffness-aware configuration assessment, sensitivity analysis, experimental design, and future model updating. The 17-pose comparison establishes a quantitative baseline that subsequent refinements must exceed."],"dc:format":["4399667","application/pdf"],"dc:identifier":["http://hdl.handle.net/2429/95450","http://circle.library.ubc.ca/bitstream/2429/95450/5/ubc_2026_november_ma_qide.pdf"],"dc:language":["eng"],"dc:publisher":["University of British Columbia"],"dc:rights":["https://creativecommons.org/licenses/by-nc-nd/4.0/","Attribution-NonCommercial-NoDerivatives 4.0 International"],"dc:title":["Redundancy-aware hybrid FE–analytical compliance modeling and experimental assessment of a 3-(P-P)PPSR hybrid parallel robot"],"dc:type":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["master's"],"thesis:degree_name":["Master of Applied Science - MASc"],"thesis:institution_name":["University of British Columbia"]},"updated_at":"2026-11-19T15:15:36Z"}