{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-2647"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-2647","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Black Writing Ink Analysis By Direct Infusion Electrospray Mass Spectroscopy","abstract":"An optimized method of extraction, an instrumental analysis method and data analysis was proposed for black writing inks based on direct infusion electrospray-mass spectrometry (ESI-MS). The sampling and analysis method is both minimally destructive and able to assess differences in inks from a reference collection of thirty ballpoint, gel, and rollerball inks. The methanol extracts of ink on paper samples were analyzed with three direct infusion (ESI-MS) methods. Each method varied scan voltage negative and positive, ESI fragmentor applied voltage (+120V, +0V, and -120V), and mobile phase additive. Direct infusion ESI-MS analysis, followed by pair-wise comparisons of the observed ion data in binary form allowed inks to be distinguished from each other. The photobleaching of the dye Basic Violet 3 (BV3) in ink-onpaper samples was examined to determine the use of degradation products as a marker of the age of the writing sample. The extent of photobleaching of BV3 was determined using several illumination sources. Pair-wise comparison of observed ion data was able to distinguish 29 of 30 ink samples using the combined three instrumental methods. Out of 435 pair-wise comparisons 429 pairs could be discriminated from each other using the combined three methods. This is a 98.6% discrimination with the combined analysis scheme","abstract_html":"An optimized method of extraction, an instrumental analysis method and data analysis was proposed for black writing inks based on direct infusion electrospray-mass spectrometry (ESI-MS). The sampling and analysis method is both minimally destructive and able to assess differences in inks from a reference collection of thirty ballpoint, gel, and rollerball inks. The methanol extracts of ink on paper samples were analyzed with three direct infusion (ESI-MS) methods. Each method varied scan voltage negative and positive, ESI fragmentor applied voltage (+120V, +0V, and -120V), and mobile phase additive. Direct infusion ESI-MS analysis, followed by pair-wise comparisons of the observed ion data in binary form allowed inks to be distinguished from each other. The photobleaching of the dye Basic Violet 3 (BV3) in ink-onpaper samples was examined to determine the use of degradation products as a marker of the age of the writing sample. The extent of photobleaching of BV3 was determined using several illumination sources. Pair-wise comparison of observed ion data was able to distinguish 29 of 30 ink samples using the combined three instrumental methods. Out of 435 pair-wise comparisons 429 pairs could be discriminated from each other using the combined three methods. This is a 98.6% discrimination with the combined analysis scheme","abstract_has_math":false,"creators":["Moody, Christopher M."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sigman, Michael"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:25:49Z","subjects":["Electrospray ionization mass spectrometry","Ink -- Analysis","Pens","Chemistry","Forensic Science and Technology","Dissertations, Academic -- Sciences, Sciences -- Dissertations, Academic"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0003563"],"render_values":[{"text":"CFE0003563","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/1648","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/1648","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-2647","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sigman, Michael"]},{"key":"dc:creator","label":"Author","values":["Moody, Christopher M."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2010-01-01T08:00:00Z","Fall","2010-12-15T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electrospray ionization mass spectrometry","Ink -- Analysis","Pens","Chemistry","Forensic Science and Technology","Dissertations, Academic -- Sciences, Sciences -- Dissertations, Academic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0003563"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/1648"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences","Forensic Science"]},{"key":"dc:description.abstract","label":"Abstract","values":["An optimized method of extraction, an instrumental analysis method and data analysis was proposed for black writing inks based on direct infusion electrospray-mass spectrometry (ESI-MS). The sampling and analysis method is both minimally destructive and able to assess differences in inks from a reference collection of thirty ballpoint, gel, and rollerball inks. The methanol extracts of ink on paper samples were analyzed with three direct infusion (ESI-MS) methods. Each method varied scan voltage negative and positive, ESI fragmentor applied voltage (+120V, +0V, and -120V), and mobile phase additive. Direct infusion ESI-MS analysis, followed by pair-wise comparisons of the observed ion data in binary form allowed inks to be distinguished from each other. The photobleaching of the dye Basic Violet 3 (BV3) in ink-onpaper samples was examined to determine the use of degradation products as a marker of the age of the writing sample. The extent of photobleaching of BV3 was determined using several illumination sources. Pair-wise comparison of observed ion data was able to distinguish 29 of 30 ink samples using the combined three instrumental methods. Out of 435 pair-wise comparisons 429 pairs could be discriminated from each other using the combined three methods. This is a 98.6% discrimination with the combined analysis scheme"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Black Writing Ink Analysis By Direct Infusion Electrospray Mass Spectroscopy"]}]}],"canonical_facts":{"dc:contributor":["Sigman, Michael"],"dc:creator":["Moody, Christopher M."],"dc:date.created":["2010-01-01T08:00:00Z","Fall","2010-12-15T08:00:00Z"],"dc:description":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences","Forensic Science"],"dc:description.abstract":["An optimized method of extraction, an instrumental analysis method and data analysis was proposed for black writing inks based on direct infusion electrospray-mass spectrometry (ESI-MS). The sampling and analysis method is both minimally destructive and able to assess differences in inks from a reference collection of thirty ballpoint, gel, and rollerball inks. The methanol extracts of ink on paper samples were analyzed with three direct infusion (ESI-MS) methods. Each method varied scan voltage negative and positive, ESI fragmentor applied voltage (+120V, +0V, and -120V), and mobile phase additive. Direct infusion ESI-MS analysis, followed by pair-wise comparisons of the observed ion data in binary form allowed inks to be distinguished from each other. The photobleaching of the dye Basic Violet 3 (BV3) in ink-onpaper samples was examined to determine the use of degradation products as a marker of the age of the writing sample. The extent of photobleaching of BV3 was determined using several illumination sources. Pair-wise comparison of observed ion data was able to distinguish 29 of 30 ink samples using the combined three instrumental methods. Out of 435 pair-wise comparisons 429 pairs could be discriminated from each other using the combined three methods. This is a 98.6% discrimination with the combined analysis scheme"],"dc:format":["application/pdf"],"dc:identifier":["CFE0003563"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/1648"],"dc:language":["English"],"dc:subject":["Electrospray ionization mass spectrometry","Ink -- Analysis","Pens","Chemistry","Forensic Science and Technology","Dissertations, Academic -- Sciences, Sciences -- Dissertations, Academic"],"dc:title":["Black Writing Ink Analysis By Direct Infusion Electrospray Mass Spectroscopy"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:25:49Z"}