{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-4283"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-4283","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"A Novel Setup For High-pressure Raman Spectroscopy Under A Microscope","abstract":"Functional properties of biological molecules and cells are affected by environmental parameters such as temperature and pressure. While Raman spectroscopy provides an intrinsic probe of molecular structural changes, the incorporation of a microscope enables studies of minuscule amounts of biological compounds with spatial resolution on a micron scale. We have developed a novel setup which combines a Raman microscope and a high pressure cell. A micro-capillary made out of fused silica simultaneously serves as the supporting body and the optical window of the pressure cell. The cell has been tested over the pressure range from 0.1 to 4 kbar. Raman spectra of less than 100 nanoliter amount of amino acid and protein solutions have been measured in the micro-capillary high pressure cell. It is also demonstrated that the setup is well suited for spectrally resolved fluorescence measurements at variable pressure.","abstract_html":"Functional properties of biological molecules and cells are affected by environmental parameters such as temperature and pressure. While Raman spectroscopy provides an intrinsic probe of molecular structural changes, the incorporation of a microscope enables studies of minuscule amounts of biological compounds with spatial resolution on a micron scale. We have developed a novel setup which combines a Raman microscope and a high pressure cell. A micro-capillary made out of fused silica simultaneously serves as the supporting body and the optical window of the pressure cell. The cell has been tested over the pressure range from 0.1 to 4 kbar. Raman spectra of less than 100 nanoliter amount of amino acid and protein solutions have been measured in the micro-capillary high pressure cell. It is also demonstrated that the setup is well suited for spectrally resolved fluorescence measurements at variable pressure.","abstract_has_math":false,"creators":["Oakeson, Thomas Andrew"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Schulte, Alfons"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:28:01Z","subjects":["high pressure raman spectroscopy","proteins","biomolecules","fluorescence","Physics"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0001683"],"render_values":[{"text":"CFE0001683","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/3283","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/3283","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-4283","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Schulte, Alfons"]},{"key":"dc:creator","label":"Author","values":["Oakeson, Thomas Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2007-01-01T08:00:00Z","Spring","2007-05-01T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["high pressure raman spectroscopy","proteins","biomolecules","fluorescence","Physics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0001683"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/3283"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Physics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"]},{"key":"dc:description.abstract","label":"Abstract","values":["Functional properties of biological molecules and cells are affected by environmental parameters such as temperature and pressure. While Raman spectroscopy provides an intrinsic probe of molecular structural changes, the incorporation of a microscope enables studies of minuscule amounts of biological compounds with spatial resolution on a micron scale. We have developed a novel setup which combines a Raman microscope and a high pressure cell. A micro-capillary made out of fused silica simultaneously serves as the supporting body and the optical window of the pressure cell. The cell has been tested over the pressure range from 0.1 to 4 kbar. Raman spectra of less than 100 nanoliter amount of amino acid and protein solutions have been measured in the micro-capillary high pressure cell. It is also demonstrated that the setup is well suited for spectrally resolved fluorescence measurements at variable pressure."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Novel Setup For High-pressure Raman Spectroscopy Under A Microscope"]}]}],"canonical_facts":{"dc:contributor":["Schulte, Alfons"],"dc:creator":["Oakeson, Thomas Andrew"],"dc:date.created":["2007-01-01T08:00:00Z","Spring","2007-05-01T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Physics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"],"dc:description.abstract":["Functional properties of biological molecules and cells are affected by environmental parameters such as temperature and pressure. While Raman spectroscopy provides an intrinsic probe of molecular structural changes, the incorporation of a microscope enables studies of minuscule amounts of biological compounds with spatial resolution on a micron scale. We have developed a novel setup which combines a Raman microscope and a high pressure cell. A micro-capillary made out of fused silica simultaneously serves as the supporting body and the optical window of the pressure cell. The cell has been tested over the pressure range from 0.1 to 4 kbar. Raman spectra of less than 100 nanoliter amount of amino acid and protein solutions have been measured in the micro-capillary high pressure cell. It is also demonstrated that the setup is well suited for spectrally resolved fluorescence measurements at variable pressure."],"dc:format":["application/pdf"],"dc:identifier":["CFE0001683"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/3283"],"dc:language":["English"],"dc:subject":["high pressure raman spectroscopy","proteins","biomolecules","fluorescence","Physics"],"dc:title":["A Novel Setup For High-pressure Raman Spectroscopy Under A Microscope"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:28:01Z"}