{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-5478"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-5478","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"4D-CT Lung Registration and its Application for Lung Radiation Therapy","abstract":"Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning.","abstract_html":"Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning.","abstract_has_math":false,"creators":["Min, Yugang"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Pattanaik, Sumanta"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:30:23Z","subjects":["Optical flow registration","radiation therapy","Computer Sciences","Engineering","Dissertations, Academic -- Engineering and Computer Science;Engineering and Computer Science -- Dissertations"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0004300"],"render_values":[{"text":"CFE0004300","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/4478","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/4478","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-5478","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Pattanaik, Sumanta"]},{"key":"dc:creator","label":"Author","values":["Min, Yugang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2012-01-01T08:00:00Z","Spring","2012-05-15T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optical flow registration","radiation therapy","Computer Sciences","Engineering","Dissertations, Academic -- Engineering and Computer Science;Engineering and Computer Science -- Dissertations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0004300"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/4478"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Computer Science","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science"]},{"key":"dc:description.abstract","label":"Abstract","values":["Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["4D-CT Lung Registration and its Application for Lung Radiation Therapy"]}]}],"canonical_facts":{"dc:contributor":["Pattanaik, Sumanta"],"dc:creator":["Min, Yugang"],"dc:date.created":["2012-01-01T08:00:00Z","Spring","2012-05-15T07:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Computer Science","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science"],"dc:description.abstract":["Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning."],"dc:format":["application/pdf"],"dc:identifier":["CFE0004300"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/4478"],"dc:language":["English"],"dc:subject":["Optical flow registration","radiation therapy","Computer Sciences","Engineering","Dissertations, Academic -- Engineering and Computer Science;Engineering and Computer Science -- Dissertations"],"dc:title":["4D-CT Lung Registration and its Application for Lung Radiation Therapy"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:30:23Z"}