{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-5797"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-5797","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Zinc Sulfide: manganese doped Quantum rods for detection of metal ions and a business model for future sales","abstract":"Hexavalent chromium is an extremely carcinogenic chemical that has been widely produced in the United States. This has led to major waste contamination and pollution throughout the country. According to the Environmental Working Group Hexavalent chromium has been found in 89% of city tap water. Most people believe they are safe using regular home filter systems however that is not true. A more expensive ion exchange water treatment unit is required. Therefore to protect yourselves from this carcinogenic metal a reliable test is required. In this study we have developed a Zinc Sulfide Manganese doped Quantum Rod technology to detect for presence of chromate and other harmful transitional metals in drinking water. Quantum Rods were synthesized using a hydrothermal reaction method. They were fully characterized using UV-visible absorption spectroscopy, fluorescence emission spectroscopy, X-ray Photoelectric Spectroscopy (XPS) and High Resolution Transmission Electron Microscopy (HRTEM). Quantum Rod metal detection studies were done with 28 different ions in a 96-well fluorescent plate reader. Results show that highest sensitivity to 8 ions including the toxic ions of chromate and mercury allowing us to create a sensor to detect these items.","abstract_html":"Hexavalent chromium is an extremely carcinogenic chemical that has been widely produced in the United States. This has led to major waste contamination and pollution throughout the country. According to the Environmental Working Group Hexavalent chromium has been found in 89% of city tap water. Most people believe they are safe using regular home filter systems however that is not true. A more expensive ion exchange water treatment unit is required. Therefore to protect yourselves from this carcinogenic metal a reliable test is required. In this study we have developed a Zinc Sulfide Manganese doped Quantum Rod technology to detect for presence of chromate and other harmful transitional metals in drinking water. Quantum Rods were synthesized using a hydrothermal reaction method. They were fully characterized using UV-visible absorption spectroscopy, fluorescence emission spectroscopy, X-ray Photoelectric Spectroscopy (XPS) and High Resolution Transmission Electron Microscopy (HRTEM). Quantum Rod metal detection studies were done with 28 different ions in a 96-well fluorescent plate reader. Results show that highest sensitivity to 8 ions including the toxic ions of chromate and mercury allowing us to create a sensor to detect these items.","abstract_has_math":false,"creators":["Teblum, Andrew"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Santra, Swadeshmukul"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:30:46Z","subjects":["Quantum rods","nano rods","metal detection","chromate","fluorescence","Environmental Public Health","Water Resource Management","Dissertations, Academic -- Graduate Studies; Graduate Studies -- Dissertations, Academic"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0005268"],"render_values":[{"text":"CFE0005268","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/4797","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/4797","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-5797","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Santra, Swadeshmukul"]},{"key":"dc:creator","label":"Author","values":["Teblum, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2014-01-01T08:00:00Z","Spring","2015-05-15T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantum rods","nano rods","metal detection","chromate","fluorescence","Environmental Public Health","Water Resource Management","Dissertations, Academic -- Graduate Studies; Graduate Studies -- Dissertations, Academic"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0005268"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/4797"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Interdisciplinary Studies","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Graduate Studies"]},{"key":"dc:description.abstract","label":"Abstract","values":["Hexavalent chromium is an extremely carcinogenic chemical that has been widely produced in the United States. This has led to major waste contamination and pollution throughout the country. According to the Environmental Working Group Hexavalent chromium has been found in 89% of city tap water. Most people believe they are safe using regular home filter systems however that is not true. A more expensive ion exchange water treatment unit is required. Therefore to protect yourselves from this carcinogenic metal a reliable test is required. In this study we have developed a Zinc Sulfide Manganese doped Quantum Rod technology to detect for presence of chromate and other harmful transitional metals in drinking water. Quantum Rods were synthesized using a hydrothermal reaction method. They were fully characterized using UV-visible absorption spectroscopy, fluorescence emission spectroscopy, X-ray Photoelectric Spectroscopy (XPS) and High Resolution Transmission Electron Microscopy (HRTEM). Quantum Rod metal detection studies were done with 28 different ions in a 96-well fluorescent plate reader. Results show that highest sensitivity to 8 ions including the toxic ions of chromate and mercury allowing us to create a sensor to detect these items."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Zinc Sulfide: manganese doped Quantum rods for detection of metal ions and a business model for future sales"]}]}],"canonical_facts":{"dc:contributor":["Santra, Swadeshmukul"],"dc:creator":["Teblum, Andrew"],"dc:date.created":["2014-01-01T08:00:00Z","Spring","2015-05-15T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Interdisciplinary Studies","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Graduate Studies"],"dc:description.abstract":["Hexavalent chromium is an extremely carcinogenic chemical that has been widely produced in the United States. This has led to major waste contamination and pollution throughout the country. According to the Environmental Working Group Hexavalent chromium has been found in 89% of city tap water. Most people believe they are safe using regular home filter systems however that is not true. A more expensive ion exchange water treatment unit is required. Therefore to protect yourselves from this carcinogenic metal a reliable test is required. In this study we have developed a Zinc Sulfide Manganese doped Quantum Rod technology to detect for presence of chromate and other harmful transitional metals in drinking water. Quantum Rods were synthesized using a hydrothermal reaction method. They were fully characterized using UV-visible absorption spectroscopy, fluorescence emission spectroscopy, X-ray Photoelectric Spectroscopy (XPS) and High Resolution Transmission Electron Microscopy (HRTEM). Quantum Rod metal detection studies were done with 28 different ions in a 96-well fluorescent plate reader. Results show that highest sensitivity to 8 ions including the toxic ions of chromate and mercury allowing us to create a sensor to detect these items."],"dc:format":["application/pdf"],"dc:identifier":["CFE0005268"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/4797"],"dc:language":["English"],"dc:subject":["Quantum rods","nano rods","metal detection","chromate","fluorescence","Environmental Public Health","Water Resource Management","Dissertations, Academic -- Graduate Studies; Graduate Studies -- Dissertations, Academic"],"dc:title":["Zinc Sulfide: manganese doped Quantum rods for detection of metal ions and a business model for future sales"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:30:46Z"}