{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-6135"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-6135","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Multi-Purpose device for analyzing and measuring ultra-short pulses","abstract":"Intensity auto correlator is device to measure pulse widths of ultrashort pulses on the order of picoseconds and femtoseconds. I have built an in-house, compact, portable, industry standard intensity auto correlator for measuring ultrashort pulse-widths. My device is suitable for pulse-widths from 500 ps to 50 fs. The impetus for developing this instrument stemmed from our development of a multicore-fiber laser for high power laser applications, which also produces very short pulses that cannot be measured with an oscilloscope. As techniques for measuring short pulse-widths have been well studied, what made my journey exciting was the process of taking an idea and realizing a successful, cost-efficient device. In this study, I have analyzed a Q-switched laser and my measured pulse-width matched the theoretical value previously calculated. I have also analyzed our mode-locked multicore fiber laser and results were encouraging. The notion to build one intensity autocorrelator was based on our labs future work, which was with modelocked multicore fiber laser, which at the moment is giving pulses on order of nanoseconds. Dr. Axel Schulzgen gave the responsibility to build an intensity autocorrelator on my shoulders. As, Intensity autocorrelators have been around for long time, he encouraged me to make one in house, compact, portable intensity autocorrelator which measures pulse widths of 50 fs up to 500 ps quite easily.","abstract_html":"Intensity auto correlator is device to measure pulse widths of ultrashort pulses on the order of picoseconds and femtoseconds. I have built an in-house, compact, portable, industry standard intensity auto correlator for measuring ultrashort pulse-widths. My device is suitable for pulse-widths from 500 ps to 50 fs. The impetus for developing this instrument stemmed from our development of a multicore-fiber laser for high power laser applications, which also produces very short pulses that cannot be measured with an oscilloscope. As techniques for measuring short pulse-widths have been well studied, what made my journey exciting was the process of taking an idea and realizing a successful, cost-efficient device. In this study, I have analyzed a Q-switched laser and my measured pulse-width matched the theoretical value previously calculated. I have also analyzed our mode-locked multicore fiber laser and results were encouraging. The notion to build one intensity autocorrelator was based on our labs future work, which was with modelocked multicore fiber laser, which at the moment is giving pulses on order of nanoseconds. Dr. Axel Schulzgen gave the responsibility to build an intensity autocorrelator on my shoulders. As, Intensity autocorrelators have been around for long time, he encouraged me to make one in house, compact, portable intensity autocorrelator which measures pulse widths of 50 fs up to 500 ps quite easily.","abstract_has_math":false,"creators":["Mehta, Naman Anilkumar"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Schulzgen, Axel"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:31:23Z","subjects":["Electromagnetics and Photonics","Optics"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0006353"],"render_values":[{"text":"CFE0006353","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/5135","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/5135","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-6135","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Schulzgen, Axel"]},{"key":"dc:creator","label":"Author","values":["Mehta, Naman Anilkumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z","Summer","2016-08-15T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electromagnetics and Photonics","Optics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0006353"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/5135"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"]},{"key":"dc:description.abstract","label":"Abstract","values":["Intensity auto correlator is device to measure pulse widths of ultrashort pulses on the order of picoseconds and femtoseconds. I have built an in-house, compact, portable, industry standard intensity auto correlator for measuring ultrashort pulse-widths. My device is suitable for pulse-widths from 500 ps to 50 fs. The impetus for developing this instrument stemmed from our development of a multicore-fiber laser for high power laser applications, which also produces very short pulses that cannot be measured with an oscilloscope. As techniques for measuring short pulse-widths have been well studied, what made my journey exciting was the process of taking an idea and realizing a successful, cost-efficient device. In this study, I have analyzed a Q-switched laser and my measured pulse-width matched the theoretical value previously calculated. I have also analyzed our mode-locked multicore fiber laser and results were encouraging. The notion to build one intensity autocorrelator was based on our labs future work, which was with modelocked multicore fiber laser, which at the moment is giving pulses on order of nanoseconds. Dr. Axel Schulzgen gave the responsibility to build an intensity autocorrelator on my shoulders. As, Intensity autocorrelators have been around for long time, he encouraged me to make one in house, compact, portable intensity autocorrelator which measures pulse widths of 50 fs up to 500 ps quite easily."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Multi-Purpose device for analyzing and measuring ultra-short pulses"]}]}],"canonical_facts":{"dc:contributor":["Schulzgen, Axel"],"dc:creator":["Mehta, Naman Anilkumar"],"dc:date.created":["2016-01-01T08:00:00Z","Summer","2016-08-15T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"],"dc:description.abstract":["Intensity auto correlator is device to measure pulse widths of ultrashort pulses on the order of picoseconds and femtoseconds. I have built an in-house, compact, portable, industry standard intensity auto correlator for measuring ultrashort pulse-widths. My device is suitable for pulse-widths from 500 ps to 50 fs. The impetus for developing this instrument stemmed from our development of a multicore-fiber laser for high power laser applications, which also produces very short pulses that cannot be measured with an oscilloscope. As techniques for measuring short pulse-widths have been well studied, what made my journey exciting was the process of taking an idea and realizing a successful, cost-efficient device. In this study, I have analyzed a Q-switched laser and my measured pulse-width matched the theoretical value previously calculated. I have also analyzed our mode-locked multicore fiber laser and results were encouraging. The notion to build one intensity autocorrelator was based on our labs future work, which was with modelocked multicore fiber laser, which at the moment is giving pulses on order of nanoseconds. Dr. Axel Schulzgen gave the responsibility to build an intensity autocorrelator on my shoulders. As, Intensity autocorrelators have been around for long time, he encouraged me to make one in house, compact, portable intensity autocorrelator which measures pulse widths of 50 fs up to 500 ps quite easily."],"dc:format":["application/pdf"],"dc:identifier":["CFE0006353"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/5135"],"dc:language":["English"],"dc:subject":["Electromagnetics and Photonics","Optics"],"dc:title":["Multi-Purpose device for analyzing and measuring ultra-short pulses"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:31:23Z"}