{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-6950"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-6950","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Development and Characterization of Solid-Contact Paper-Based and Micro Ion-Selective Electrodes for Environmental Analysis","abstract":"Ion-selective electrodes (ISEs) have extensively been used for food analysis, as medical diagnostic tools, and for some environmental applications. However, ISEs are hindered by the need of a bulky reference electrode and the pre-conditioning step of the sensor, which can often be lengthy. This work will discuss how the direct addition of target analyte into the cocktail sensing membrane can circumvent the pre-conditioning step. Furthermore, the work is presented in an optimized ready-to-use single strip design, where the bulky glass reference electrode (RE) is no longer needed. The bulky RE was replaced by drop casting a simple two-component mixture consisting of the co-polymer methyl methacrylate-co-decyl methacrylate and the ionic liquid 1-Ethyl-3-methylimidazolium bis (trifluoromethane sulfonyl) amide. Furthermore, this work will also highlight the benefits of solid-contact ISEs, specifically focusing on two solid- contact platforms: 1) paper-based and 2) a micro-electrode platform. Paper-based based sensors were designed to be used as a possible diagnostic tool to be implemented in undeveloped countries to monitor low levels of potassium and iodide, as model ions. The micro(µ) ISEs were applied for the in-situ analysis of zinc in citrus plants as a mean to monitor and assess disease progression or therapy.","abstract_html":"Ion-selective electrodes (ISEs) have extensively been used for food analysis, as medical diagnostic tools, and for some environmental applications. However, ISEs are hindered by the need of a bulky reference electrode and the pre-conditioning step of the sensor, which can often be lengthy. This work will discuss how the direct addition of target analyte into the cocktail sensing membrane can circumvent the pre-conditioning step. Furthermore, the work is presented in an optimized ready-to-use single strip design, where the bulky glass reference electrode (RE) is no longer needed. The bulky RE was replaced by drop casting a simple two-component mixture consisting of the co-polymer methyl methacrylate-co-decyl methacrylate and the ionic liquid 1-Ethyl-3-methylimidazolium bis (trifluoromethane sulfonyl) amide. Furthermore, this work will also highlight the benefits of solid-contact ISEs, specifically focusing on two solid- contact platforms: 1) paper-based and 2) a micro-electrode platform. Paper-based based sensors were designed to be used as a possible diagnostic tool to be implemented in undeveloped countries to monitor low levels of potassium and iodide, as model ions. The micro(µ) ISEs were applied for the in-situ analysis of zinc in citrus plants as a mean to monitor and assess disease progression or therapy.","abstract_has_math":false,"creators":["Armas, Stephanie"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Chumbimuni Torres, Karin"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:32:44Z","subjects":["Chemistry"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007243"],"render_values":[{"text":"CFE0007243","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/5950","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/5950","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-6950","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chumbimuni Torres, Karin"]},{"key":"dc:creator","label":"Author","values":["Armas, Stephanie"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2018-01-01T08:00:00Z","Summer","2018-08-15T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007243"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/5950"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"]},{"key":"dc:description.abstract","label":"Abstract","values":["Ion-selective electrodes (ISEs) have extensively been used for food analysis, as medical diagnostic tools, and for some environmental applications. However, ISEs are hindered by the need of a bulky reference electrode and the pre-conditioning step of the sensor, which can often be lengthy. This work will discuss how the direct addition of target analyte into the cocktail sensing membrane can circumvent the pre-conditioning step. Furthermore, the work is presented in an optimized ready-to-use single strip design, where the bulky glass reference electrode (RE) is no longer needed. The bulky RE was replaced by drop casting a simple two-component mixture consisting of the co-polymer methyl methacrylate-co-decyl methacrylate and the ionic liquid 1-Ethyl-3-methylimidazolium bis (trifluoromethane sulfonyl) amide. Furthermore, this work will also highlight the benefits of solid-contact ISEs, specifically focusing on two solid- contact platforms: 1) paper-based and 2) a micro-electrode platform. Paper-based based sensors were designed to be used as a possible diagnostic tool to be implemented in undeveloped countries to monitor low levels of potassium and iodide, as model ions. The micro(µ) ISEs were applied for the in-situ analysis of zinc in citrus plants as a mean to monitor and assess disease progression or therapy."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and Characterization of Solid-Contact Paper-Based and Micro Ion-Selective Electrodes for Environmental Analysis"]}]}],"canonical_facts":{"dc:contributor":["Chumbimuni Torres, Karin"],"dc:creator":["Armas, Stephanie"],"dc:date.created":["2018-01-01T08:00:00Z","Summer","2018-08-15T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"],"dc:description.abstract":["Ion-selective electrodes (ISEs) have extensively been used for food analysis, as medical diagnostic tools, and for some environmental applications. However, ISEs are hindered by the need of a bulky reference electrode and the pre-conditioning step of the sensor, which can often be lengthy. This work will discuss how the direct addition of target analyte into the cocktail sensing membrane can circumvent the pre-conditioning step. Furthermore, the work is presented in an optimized ready-to-use single strip design, where the bulky glass reference electrode (RE) is no longer needed. The bulky RE was replaced by drop casting a simple two-component mixture consisting of the co-polymer methyl methacrylate-co-decyl methacrylate and the ionic liquid 1-Ethyl-3-methylimidazolium bis (trifluoromethane sulfonyl) amide. Furthermore, this work will also highlight the benefits of solid-contact ISEs, specifically focusing on two solid- contact platforms: 1) paper-based and 2) a micro-electrode platform. Paper-based based sensors were designed to be used as a possible diagnostic tool to be implemented in undeveloped countries to monitor low levels of potassium and iodide, as model ions. The micro(µ) ISEs were applied for the in-situ analysis of zinc in citrus plants as a mean to monitor and assess disease progression or therapy."],"dc:format":["application/pdf"],"dc:identifier":["CFE0007243"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/5950"],"dc:language":["English"],"dc:subject":["Chemistry"],"dc:title":["Development and Characterization of Solid-Contact Paper-Based and Micro Ion-Selective Electrodes for Environmental Analysis"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:32:44Z"}