{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-7283"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-7283","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Engineering Noble-metal Nanostructures for Biosensing Applications","abstract":"The ability to engineer noble-metal nanostructures (NMNSs) in a controllable manner and to understand the structure-dependent properties greatly boost our knowledge in rational design of biosensing technologies. In particular, as a type of highly efficient peroxidase mimics, NMNSs hold promising potential to break through the bottleneck of conventional enzyme-based in vitro diagnostics. During the time of my Ph.D. study, I have successfully: 1) directed a two-step method involving seed-mediated growth and chemical etching for the synthesis of Ru nanoframes (RuNFs) with face-centered cubic crystal phase and enhanced catalytic activities; 2) demonstrated, for the first time, the inherent peroxidase-like activity of RuNFs as a type of efficient peroxidase mimics, opening up possibilities for their bioapplications; 3) developed an enzyme-free signal amplification technique for ultrasensitive colorimetric assay of disease biomarkers by using Pd-Ir nanooctahedra encapsulated gold vesicles as labels; 4) prepared polyvinylpyrrolidone (PVP)-capped Pt nanocubes with superior peroxidase-like catalytic activity and record-high specific catalytic activity; 5) developed a facile colorimetric method for the detection of Ag(I) ions with picomolar sensitivity by using the PVP-capped Pt nanocubes as the probes; 6) developed a non-enzyme cascade amplification strategy for colorimetric assay of disease biomarkers by taking advantage of the interaction between the Ag(I) ions and PVP-capped Pt nanocubes; and 7) established a highly sensitive colorimetric lateral flow assay platform by using Au@Pt core-shell nanoparticles as the labels that possess both plasmonic and catalytic properties.","abstract_html":"The ability to engineer noble-metal nanostructures (NMNSs) in a controllable manner and to understand the structure-dependent properties greatly boost our knowledge in rational design of biosensing technologies. In particular, as a type of highly efficient peroxidase mimics, NMNSs hold promising potential to break through the bottleneck of conventional enzyme-based in vitro diagnostics. During the time of my Ph.D. study, I have successfully: 1) directed a two-step method involving seed-mediated growth and chemical etching for the synthesis of Ru nanoframes (RuNFs) with face-centered cubic crystal phase and enhanced catalytic activities; 2) demonstrated, for the first time, the inherent peroxidase-like activity of RuNFs as a type of efficient peroxidase mimics, opening up possibilities for their bioapplications; 3) developed an enzyme-free signal amplification technique for ultrasensitive colorimetric assay of disease biomarkers by using Pd-Ir nanooctahedra encapsulated gold vesicles as labels; 4) prepared polyvinylpyrrolidone (PVP)-capped Pt nanocubes with superior peroxidase-like catalytic activity and record-high specific catalytic activity; 5) developed a facile colorimetric method for the detection of Ag(I) ions with picomolar sensitivity by using the PVP-capped Pt nanocubes as the probes; 6) developed a non-enzyme cascade amplification strategy for colorimetric assay of disease biomarkers by taking advantage of the interaction between the Ag(I) ions and PVP-capped Pt nanocubes; and 7) established a highly sensitive colorimetric lateral flow assay platform by using Au@Pt core-shell nanoparticles as the labels that possess both plasmonic and catalytic properties.","abstract_has_math":false,"creators":["Ye, Haihang"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Xia, Xiaohu"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:33:10Z","subjects":["Chemistry"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007559"],"render_values":[{"text":"CFE0007559","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/6283","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/6283","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-7283","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Xia, Xiaohu"]},{"key":"dc:creator","label":"Author","values":["Ye, Haihang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2019-05-01T07:00:00Z","Spring","2019-05-15T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007559"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/6283"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"]},{"key":"dc:description.abstract","label":"Abstract","values":["The ability to engineer noble-metal nanostructures (NMNSs) in a controllable manner and to understand the structure-dependent properties greatly boost our knowledge in rational design of biosensing technologies. In particular, as a type of highly efficient peroxidase mimics, NMNSs hold promising potential to break through the bottleneck of conventional enzyme-based in vitro diagnostics. During the time of my Ph.D. study, I have successfully: 1) directed a two-step method involving seed-mediated growth and chemical etching for the synthesis of Ru nanoframes (RuNFs) with face-centered cubic crystal phase and enhanced catalytic activities; 2) demonstrated, for the first time, the inherent peroxidase-like activity of RuNFs as a type of efficient peroxidase mimics, opening up possibilities for their bioapplications; 3) developed an enzyme-free signal amplification technique for ultrasensitive colorimetric assay of disease biomarkers by using Pd-Ir nanooctahedra encapsulated gold vesicles as labels; 4) prepared polyvinylpyrrolidone (PVP)-capped Pt nanocubes with superior peroxidase-like catalytic activity and record-high specific catalytic activity; 5) developed a facile colorimetric method for the detection of Ag(I) ions with picomolar sensitivity by using the PVP-capped Pt nanocubes as the probes; 6) developed a non-enzyme cascade amplification strategy for colorimetric assay of disease biomarkers by taking advantage of the interaction between the Ag(I) ions and PVP-capped Pt nanocubes; and 7) established a highly sensitive colorimetric lateral flow assay platform by using Au@Pt core-shell nanoparticles as the labels that possess both plasmonic and catalytic properties."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Engineering Noble-metal Nanostructures for Biosensing Applications"]}]}],"canonical_facts":{"dc:contributor":["Xia, Xiaohu"],"dc:creator":["Ye, Haihang"],"dc:date.created":["2019-05-01T07:00:00Z","Spring","2019-05-15T07:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"],"dc:description.abstract":["The ability to engineer noble-metal nanostructures (NMNSs) in a controllable manner and to understand the structure-dependent properties greatly boost our knowledge in rational design of biosensing technologies. In particular, as a type of highly efficient peroxidase mimics, NMNSs hold promising potential to break through the bottleneck of conventional enzyme-based in vitro diagnostics. During the time of my Ph.D. study, I have successfully: 1) directed a two-step method involving seed-mediated growth and chemical etching for the synthesis of Ru nanoframes (RuNFs) with face-centered cubic crystal phase and enhanced catalytic activities; 2) demonstrated, for the first time, the inherent peroxidase-like activity of RuNFs as a type of efficient peroxidase mimics, opening up possibilities for their bioapplications; 3) developed an enzyme-free signal amplification technique for ultrasensitive colorimetric assay of disease biomarkers by using Pd-Ir nanooctahedra encapsulated gold vesicles as labels; 4) prepared polyvinylpyrrolidone (PVP)-capped Pt nanocubes with superior peroxidase-like catalytic activity and record-high specific catalytic activity; 5) developed a facile colorimetric method for the detection of Ag(I) ions with picomolar sensitivity by using the PVP-capped Pt nanocubes as the probes; 6) developed a non-enzyme cascade amplification strategy for colorimetric assay of disease biomarkers by taking advantage of the interaction between the Ag(I) ions and PVP-capped Pt nanocubes; and 7) established a highly sensitive colorimetric lateral flow assay platform by using Au@Pt core-shell nanoparticles as the labels that possess both plasmonic and catalytic properties."],"dc:format":["application/pdf"],"dc:identifier":["CFE0007559"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/6283"],"dc:language":["English"],"dc:subject":["Chemistry"],"dc:title":["Engineering Noble-metal Nanostructures for Biosensing Applications"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:33:10Z"}