{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd-7750"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd-7750","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Detection of DDH in Infants and Children Using Audible Acoustics","abstract":"Detection of developmental dysplasia of the hip (DDH) in infants and children is important as it leads to permanent hip instability. Current methods for detecting DDH, such as ultrasound and x-rays, are relatively expensive and need qualified medical personnel to administer the test. Furthermore, x-ray ionizing radiation can have potential harmful effects. In the current study, an acoustic non-invasive and simple approach was investigated for detection of DDH. Different benchtop simplified models and pig models were constructed and tested. Models were stimulated with band-limited white acoustic noise (10-2500 Hz) and the response of the models was measured. The power spectrum density, transfer function, and coherence were determined for different hip dysplasia levels and for normal cases. Results showed that the power spectrum density, transfer function, and coherence were affected by dysplasia occurrence. Effects appear larger for more severe dysplastic hips. This suggests that the proposed approach may have potential for DDH detection.","abstract_html":"Detection of developmental dysplasia of the hip (DDH) in infants and children is important as it leads to permanent hip instability. Current methods for detecting DDH, such as ultrasound and x-rays, are relatively expensive and need qualified medical personnel to administer the test. Furthermore, x-ray ionizing radiation can have potential harmful effects. In the current study, an acoustic non-invasive and simple approach was investigated for detection of DDH. Different benchtop simplified models and pig models were constructed and tested. Models were stimulated with band-limited white acoustic noise (10-2500 Hz) and the response of the models was measured. The power spectrum density, transfer function, and coherence were determined for different hip dysplasia levels and for normal cases. Results showed that the power spectrum density, transfer function, and coherence were affected by dysplasia occurrence. Effects appear larger for more severe dysplastic hips. This suggests that the proposed approach may have potential for DDH detection.","abstract_has_math":false,"creators":["Hassan, Tanvir"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Mansy, Hansen"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:33:47Z","subjects":["Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007816"],"render_values":[{"text":"CFE0007816","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd/6750","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd/6750","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd-7750","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Mansy, Hansen"]},{"key":"dc:creator","label":"Author","values":["Hassan, Tanvir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z","Fall","2019-12-15T08:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007816"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd/6750"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science in Mechanical Engineering (M.S.M.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering; Thermo-Fluids"]},{"key":"dc:description.abstract","label":"Abstract","values":["Detection of developmental dysplasia of the hip (DDH) in infants and children is important as it leads to permanent hip instability. Current methods for detecting DDH, such as ultrasound and x-rays, are relatively expensive and need qualified medical personnel to administer the test. Furthermore, x-ray ionizing radiation can have potential harmful effects. In the current study, an acoustic non-invasive and simple approach was investigated for detection of DDH. Different benchtop simplified models and pig models were constructed and tested. Models were stimulated with band-limited white acoustic noise (10-2500 Hz) and the response of the models was measured. The power spectrum density, transfer function, and coherence were determined for different hip dysplasia levels and for normal cases. Results showed that the power spectrum density, transfer function, and coherence were affected by dysplasia occurrence. Effects appear larger for more severe dysplastic hips. This suggests that the proposed approach may have potential for DDH detection."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Detection of DDH in Infants and Children Using Audible Acoustics"]}]}],"canonical_facts":{"dc:contributor":["Mansy, Hansen"],"dc:creator":["Hassan, Tanvir"],"dc:date.created":["2019-01-01T08:00:00Z","Fall","2019-12-15T08:00:00Z"],"dc:description":["Master of Science in Mechanical Engineering (M.S.M.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:STARS@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering; Thermo-Fluids"],"dc:description.abstract":["Detection of developmental dysplasia of the hip (DDH) in infants and children is important as it leads to permanent hip instability. Current methods for detecting DDH, such as ultrasound and x-rays, are relatively expensive and need qualified medical personnel to administer the test. Furthermore, x-ray ionizing radiation can have potential harmful effects. In the current study, an acoustic non-invasive and simple approach was investigated for detection of DDH. Different benchtop simplified models and pig models were constructed and tested. Models were stimulated with band-limited white acoustic noise (10-2500 Hz) and the response of the models was measured. The power spectrum density, transfer function, and coherence were determined for different hip dysplasia levels and for normal cases. Results showed that the power spectrum density, transfer function, and coherence were affected by dysplasia occurrence. Effects appear larger for more severe dysplastic hips. This suggests that the proposed approach may have potential for DDH detection."],"dc:format":["application/pdf"],"dc:identifier":["CFE0007816"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd/6750"],"dc:language":["English"],"dc:subject":["Mechanical Engineering"],"dc:title":["Detection of DDH in Infants and Children Using Audible Acoustics"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:33:47Z"}