{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1083"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1083","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Multi-parameter Optical Metrology: Quantum and Classical","abstract":"The insights offered by quantum mechanics to the field of optical metrology are many-fold, with non-classical states of light themselves used to make sensors that surpass the sensitivity of sensors using classical states of light. Unfortunately, this advantage, referred to often as \"super-sensitivity\" is notoriously fragile, and even the slightest experimental imperfections may greatly reduce the efficacy of the non-classical sensors, sometimes completely obviating their advantage. In my thesis I have shown that the performance of an otherwise ideal two-photon interferometer, which exploits entanglement between photons to make super-sensitive measurements of phase, is crippled by the slightest introduction of decoherence between modes of the interferometer. I have shown further that such drastic reduction in sensitivity can also appear in classical measurement problems, specifically that the recently developed methods of estimating the separation between a pair of point sources are rendered less effective when the ideal assumption of complete spatial incoherence is relaxed. Towards overcoming these and other issues, I have designed new configurations that use ancillary optical degrees of freedom, a tool-set that has recently garnered much interest in the field of quantum optics. In the context of two-photon interferometry, I have shown that by coupling polarization to the spatial-structure of the two photon state used to probe phase it is possible to obviate the need for a reference phase, even in the context of decoherence and imperfections in the interferometer. In the context of two-point resolution, I have developed an anisotropic imaging system that performs the function of an image-inversion interferometer and is inherently stable, offering an attractive implementation of recently developed methods of sub-Rayleigh imaging. I have further shown both theoretically and experimentally that the same anisotropic image-inversion interferometer is useful in measuring spatially encoded phases, both in the context of classical illumination as well as quantum-aided two-photon super-sensing. In both cases, the ability to perform interferometric measurements of the spatial structure of an electric field without splitting beam paths forms a bridge between conception and implementation of precision-sensing measurement strategies. Finally, I have shown that binary interferometric method based on the common-path anisotropic imaging system that I introduced, are able to measure both phase gradients and transverse beam tilts with a sensitivity beating conventional systems that are used both commercially and in research laboratories.","abstract_html":"The insights offered by quantum mechanics to the field of optical metrology are many-fold, with non-classical states of light themselves used to make sensors that surpass the sensitivity of sensors using classical states of light. Unfortunately, this advantage, referred to often as &quot;super-sensitivity&quot; is notoriously fragile, and even the slightest experimental imperfections may greatly reduce the efficacy of the non-classical sensors, sometimes completely obviating their advantage. In my thesis I have shown that the performance of an otherwise ideal two-photon interferometer, which exploits entanglement between photons to make super-sensitive measurements of phase, is crippled by the slightest introduction of decoherence between modes of the interferometer. I have shown further that such drastic reduction in sensitivity can also appear in classical measurement problems, specifically that the recently developed methods of estimating the separation between a pair of point sources are rendered less effective when the ideal assumption of complete spatial incoherence is relaxed. Towards overcoming these and other issues, I have designed new configurations that use ancillary optical degrees of freedom, a tool-set that has recently garnered much interest in the field of quantum optics. In the context of two-photon interferometry, I have shown that by coupling polarization to the spatial-structure of the two photon state used to probe phase it is possible to obviate the need for a reference phase, even in the context of decoherence and imperfections in the interferometer. In the context of two-point resolution, I have developed an anisotropic imaging system that performs the function of an image-inversion interferometer and is inherently stable, offering an attractive implementation of recently developed methods of sub-Rayleigh imaging. I have further shown both theoretically and experimentally that the same anisotropic image-inversion interferometer is useful in measuring spatially encoded phases, both in the context of classical illumination as well as quantum-aided two-photon super-sensing. In both cases, the ability to perform interferometric measurements of the spatial structure of an electric field without splitting beam paths forms a bridge between conception and implementation of precision-sensing measurement strategies. Finally, I have shown that binary interferometric method based on the common-path anisotropic imaging system that I introduced, are able to measure both phase gradients and transverse beam tilts with a sensitivity beating conventional systems that are used both commercially and in research laboratories.","abstract_has_math":false,"creators":["Larson, Walker"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Saleh, Bahaa"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:42:55Z","subjects":["Quantum metrology; Two-photon interferometry; Sensitivity analysis; Decoherence; Sub-Rayleigh imaging","Electromagnetics and Photonics","Optics","Quantum optics--Measurement; Optical interferometers; Quantum optics--Technique; Optical measurements; Interferometers"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007990; DP0023130"],"render_values":[{"text":"CFE0007990; DP0023130","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/84","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/84","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1083","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Saleh, Bahaa"]},{"key":"dc:creator","label":"Author","values":["Larson, Walker"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z","Spring","2020-05-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Quantum metrology; Two-photon interferometry; Sensitivity analysis; Decoherence; Sub-Rayleigh imaging","Electromagnetics and Photonics","Optics","Quantum optics--Measurement; Optical interferometers; Quantum optics--Technique; Optical measurements; Interferometers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0007990; DP0023130"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/84"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"]},{"key":"dc:description.abstract","label":"Abstract","values":["The insights offered by quantum mechanics to the field of optical metrology are many-fold, with non-classical states of light themselves used to make sensors that surpass the sensitivity of sensors using classical states of light. Unfortunately, this advantage, referred to often as \"super-sensitivity\" is notoriously fragile, and even the slightest experimental imperfections may greatly reduce the efficacy of the non-classical sensors, sometimes completely obviating their advantage. In my thesis I have shown that the performance of an otherwise ideal two-photon interferometer, which exploits entanglement between photons to make super-sensitive measurements of phase, is crippled by the slightest introduction of decoherence between modes of the interferometer. I have shown further that such drastic reduction in sensitivity can also appear in classical measurement problems, specifically that the recently developed methods of estimating the separation between a pair of point sources are rendered less effective when the ideal assumption of complete spatial incoherence is relaxed. Towards overcoming these and other issues, I have designed new configurations that use ancillary optical degrees of freedom, a tool-set that has recently garnered much interest in the field of quantum optics. In the context of two-photon interferometry, I have shown that by coupling polarization to the spatial-structure of the two photon state used to probe phase it is possible to obviate the need for a reference phase, even in the context of decoherence and imperfections in the interferometer. In the context of two-point resolution, I have developed an anisotropic imaging system that performs the function of an image-inversion interferometer and is inherently stable, offering an attractive implementation of recently developed methods of sub-Rayleigh imaging. I have further shown both theoretically and experimentally that the same anisotropic image-inversion interferometer is useful in measuring spatially encoded phases, both in the context of classical illumination as well as quantum-aided two-photon super-sensing. In both cases, the ability to perform interferometric measurements of the spatial structure of an electric field without splitting beam paths forms a bridge between conception and implementation of precision-sensing measurement strategies. Finally, I have shown that binary interferometric method based on the common-path anisotropic imaging system that I introduced, are able to measure both phase gradients and transverse beam tilts with a sensitivity beating conventional systems that are used both commercially and in research laboratories."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Multi-parameter Optical Metrology: Quantum and Classical"]}]}],"canonical_facts":{"dc:contributor":["Saleh, Bahaa"],"dc:creator":["Larson, Walker"],"dc:date.created":["2020-01-01T08:00:00Z","Spring","2020-05-15T07:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"],"dc:description.abstract":["The insights offered by quantum mechanics to the field of optical metrology are many-fold, with non-classical states of light themselves used to make sensors that surpass the sensitivity of sensors using classical states of light. Unfortunately, this advantage, referred to often as \"super-sensitivity\" is notoriously fragile, and even the slightest experimental imperfections may greatly reduce the efficacy of the non-classical sensors, sometimes completely obviating their advantage. In my thesis I have shown that the performance of an otherwise ideal two-photon interferometer, which exploits entanglement between photons to make super-sensitive measurements of phase, is crippled by the slightest introduction of decoherence between modes of the interferometer. I have shown further that such drastic reduction in sensitivity can also appear in classical measurement problems, specifically that the recently developed methods of estimating the separation between a pair of point sources are rendered less effective when the ideal assumption of complete spatial incoherence is relaxed. Towards overcoming these and other issues, I have designed new configurations that use ancillary optical degrees of freedom, a tool-set that has recently garnered much interest in the field of quantum optics. In the context of two-photon interferometry, I have shown that by coupling polarization to the spatial-structure of the two photon state used to probe phase it is possible to obviate the need for a reference phase, even in the context of decoherence and imperfections in the interferometer. In the context of two-point resolution, I have developed an anisotropic imaging system that performs the function of an image-inversion interferometer and is inherently stable, offering an attractive implementation of recently developed methods of sub-Rayleigh imaging. I have further shown both theoretically and experimentally that the same anisotropic image-inversion interferometer is useful in measuring spatially encoded phases, both in the context of classical illumination as well as quantum-aided two-photon super-sensing. In both cases, the ability to perform interferometric measurements of the spatial structure of an electric field without splitting beam paths forms a bridge between conception and implementation of precision-sensing measurement strategies. Finally, I have shown that binary interferometric method based on the common-path anisotropic imaging system that I introduced, are able to measure both phase gradients and transverse beam tilts with a sensitivity beating conventional systems that are used both commercially and in research laboratories."],"dc:format":["application/pdf"],"dc:identifier":["CFE0007990; DP0023130"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/84"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Quantum metrology; Two-photon interferometry; Sensitivity analysis; Decoherence; Sub-Rayleigh imaging","Electromagnetics and Photonics","Optics","Quantum optics--Measurement; Optical interferometers; Quantum optics--Technique; Optical measurements; Interferometers"],"dc:title":["Multi-parameter Optical Metrology: Quantum and Classical"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:42:55Z"}