{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1139"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1139","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Fluorescence Microscopy with Tailored Illumination Light","abstract":"Fluorescence microscopy has long been a valuable tool for biological and medical imaging. Control of optical parameters such as the amplitude, phase, polarization and propagation angle of light gives fluorescence imaging great capabilities ranging from single molecule imaging to long-term observation of living organisms. While numerous fluorescence imaging techniques have been developed over the past decades, there is always an inevitable tradeoff among the spatial resolution, imaging speed, contrast, photodamage and the total cost when it comes to choose the appropriate microscope. A main goal of my dissertation research is to develop state-of-the-art microscope systems that exhibit unprecedented performance in single-molecule fluorescence imaging and live-cell imaging for broader biomedical applications by tailoring the optical illumination beams. In details, I have designed and prototyped: 1) a highly inclined swept illumination for wide-field fluorescence microscope, which greatly improves the sectioning capability with a large field of view and ultrasensitivity; 2) dual inclined line-scan confocal microscope, which reduces photodamage while maintaining the background rejection capability compared to conventional line-scan confocal microscope; 3) a static non-diffracting light-sheet generation by controlling the spatial coherence of light emitting diodes and laser.","abstract_html":"Fluorescence microscopy has long been a valuable tool for biological and medical imaging. Control of optical parameters such as the amplitude, phase, polarization and propagation angle of light gives fluorescence imaging great capabilities ranging from single molecule imaging to long-term observation of living organisms. While numerous fluorescence imaging techniques have been developed over the past decades, there is always an inevitable tradeoff among the spatial resolution, imaging speed, contrast, photodamage and the total cost when it comes to choose the appropriate microscope. A main goal of my dissertation research is to develop state-of-the-art microscope systems that exhibit unprecedented performance in single-molecule fluorescence imaging and live-cell imaging for broader biomedical applications by tailoring the optical illumination beams. In details, I have designed and prototyped: 1) a highly inclined swept illumination for wide-field fluorescence microscope, which greatly improves the sectioning capability with a large field of view and ultrasensitivity; 2) dual inclined line-scan confocal microscope, which reduces photodamage while maintaining the background rejection capability compared to conventional line-scan confocal microscope; 3) a static non-diffracting light-sheet generation by controlling the spatial coherence of light emitting diodes and laser.","abstract_has_math":false,"creators":["Tang, Jialei"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Han, Kyu Young"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:42:55Z","subjects":["Optical engineering; Biomedical applications; Single-molecule imaging; Live-cell imaging; Illumination techniques","Electromagnetics and Photonics","Optics","Fluorescence microscopy; Fluorescence microscopy--Methodology; Confocal fluorescence microscopy; Imaging systems in biology; Optics--Technological innovations"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008046; DP0023186"],"render_values":[{"text":"CFE0008046; DP0023186","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/140","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/140","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucf%3Aoai%3Astars.library.ucf.edu%3Aetd2020-1139","prefix":"oai_dc"},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1139","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Han, Kyu Young"]},{"key":"dc:creator","label":"Author","values":["Tang, Jialei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z","Spring","2023-05-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optical engineering; Biomedical applications; Single-molecule imaging; Live-cell imaging; Illumination techniques","Electromagnetics and Photonics","Optics","Fluorescence microscopy; Fluorescence microscopy--Methodology; Confocal fluorescence microscopy; Imaging systems in biology; Optics--Technological innovations"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008046; DP0023186"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/140"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"]},{"key":"dc:description.abstract","label":"Abstract","values":["Fluorescence microscopy has long been a valuable tool for biological and medical imaging. Control of optical parameters such as the amplitude, phase, polarization and propagation angle of light gives fluorescence imaging great capabilities ranging from single molecule imaging to long-term observation of living organisms. While numerous fluorescence imaging techniques have been developed over the past decades, there is always an inevitable tradeoff among the spatial resolution, imaging speed, contrast, photodamage and the total cost when it comes to choose the appropriate microscope. A main goal of my dissertation research is to develop state-of-the-art microscope systems that exhibit unprecedented performance in single-molecule fluorescence imaging and live-cell imaging for broader biomedical applications by tailoring the optical illumination beams. In details, I have designed and prototyped: 1) a highly inclined swept illumination for wide-field fluorescence microscope, which greatly improves the sectioning capability with a large field of view and ultrasensitivity; 2) dual inclined line-scan confocal microscope, which reduces photodamage while maintaining the background rejection capability compared to conventional line-scan confocal microscope; 3) a static non-diffracting light-sheet generation by controlling the spatial coherence of light emitting diodes and laser."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Fluorescence Microscopy with Tailored Illumination Light"]}]}],"canonical_facts":{"dc:contributor":["Han, Kyu Young"],"dc:creator":["Tang, Jialei"],"dc:date.created":["2020-01-01T08:00:00Z","Spring","2023-05-15T07:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Optics and Photonics","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Optics and Photonics"],"dc:description.abstract":["Fluorescence microscopy has long been a valuable tool for biological and medical imaging. Control of optical parameters such as the amplitude, phase, polarization and propagation angle of light gives fluorescence imaging great capabilities ranging from single molecule imaging to long-term observation of living organisms. While numerous fluorescence imaging techniques have been developed over the past decades, there is always an inevitable tradeoff among the spatial resolution, imaging speed, contrast, photodamage and the total cost when it comes to choose the appropriate microscope. A main goal of my dissertation research is to develop state-of-the-art microscope systems that exhibit unprecedented performance in single-molecule fluorescence imaging and live-cell imaging for broader biomedical applications by tailoring the optical illumination beams. In details, I have designed and prototyped: 1) a highly inclined swept illumination for wide-field fluorescence microscope, which greatly improves the sectioning capability with a large field of view and ultrasensitivity; 2) dual inclined line-scan confocal microscope, which reduces photodamage while maintaining the background rejection capability compared to conventional line-scan confocal microscope; 3) a static non-diffracting light-sheet generation by controlling the spatial coherence of light emitting diodes and laser."],"dc:format":["application/pdf"],"dc:identifier":["CFE0008046; DP0023186"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/140"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Optical engineering; Biomedical applications; Single-molecule imaging; Live-cell imaging; Illumination techniques","Electromagnetics and Photonics","Optics","Fluorescence microscopy; Fluorescence microscopy--Methodology; Confocal fluorescence microscopy; Imaging systems in biology; Optics--Technological innovations"],"dc:title":["Fluorescence Microscopy with Tailored Illumination Light"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:42:55Z"}