{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1237"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1237","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Characterization of Clear Coat and Base Coat Automotive Paint Analysis Using DART-HRMS and Comparison of FTIR Spectroscopy, Py-GC-MS, and DART-HRMS for Clear Coat Analysis","abstract":"Current techniques used to analyze automotive paint samples include microscopy, fourier – transform infrared (FTIR) spectroscopy, and pyrolysis gas chromatography - mass spectrometry (Py-GC-MS). These techniques are performed in the respective order listed above. Out of the three techniques currently used in this field, the one that has the highest discriminatory power is py-GC-MS; however, this technique is time consuming and destructive toward the sample. One hundred automotive paint samples were analyzed using FTIR, Py-GC-MS and direct analysis in real time-high resolution mass spectrometry (DART-HRMS) to determine how DART-HRMS compared to Py-GC-MS in terms of discriminatory capability. DART-HRMS takes approximately 4 minutes to run a sample while Py-GC-MS takes around 24 minutes per sample. The vast difference in analysis run times between the two techniques could help prevent and/or get rid of current backlogs in forensic trace labs. The clear coat and base coat of automotive paint samples were analyzed using DART-HRMS to compare the different information obtained for the separate layers. The accuracies of the models, based on LDA, were 86.77%, 87.98%, 95.61%, and 98.20% for DART-HRMS (base coat), FTIR, Py-GC-MS, and DART-HRMS (clear coat), respectively. This demonstrates that DART-HRMS can be utilized when analyzing automotive paint samples to achieve a higher discriminatory power while also analyzing samples in a fraction of the time that Py-GC-MS takes.","abstract_html":"Current techniques used to analyze automotive paint samples include microscopy, fourier – transform infrared (FTIR) spectroscopy, and pyrolysis gas chromatography - mass spectrometry (Py-GC-MS). These techniques are performed in the respective order listed above. Out of the three techniques currently used in this field, the one that has the highest discriminatory power is py-GC-MS; however, this technique is time consuming and destructive toward the sample. One hundred automotive paint samples were analyzed using FTIR, Py-GC-MS and direct analysis in real time-high resolution mass spectrometry (DART-HRMS) to determine how DART-HRMS compared to Py-GC-MS in terms of discriminatory capability. DART-HRMS takes approximately 4 minutes to run a sample while Py-GC-MS takes around 24 minutes per sample. The vast difference in analysis run times between the two techniques could help prevent and/or get rid of current backlogs in forensic trace labs. The clear coat and base coat of automotive paint samples were analyzed using DART-HRMS to compare the different information obtained for the separate layers. The accuracies of the models, based on LDA, were 86.77%, 87.98%, 95.61%, and 98.20% for DART-HRMS (base coat), FTIR, Py-GC-MS, and DART-HRMS (clear coat), respectively. This demonstrates that DART-HRMS can be utilized when analyzing automotive paint samples to achieve a higher discriminatory power while also analyzing samples in a fraction of the time that Py-GC-MS takes.","abstract_has_math":false,"creators":["Jones, Kaitlin"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Bridge, Candice"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:40:57Z","subjects":["Automotive paint analysis; DART-HRMS; FTIR spectroscopy; Py-GC-MS; Forensic techniques","Chemistry","Coatings--Analysis; Paint materials--Analysis; Mass spectrometry--Forensic applications; Gas chromatography--Forensic applications; Coatings--Evaluation"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008187; DP0023541"],"render_values":[{"text":"CFE0008187; DP0023541","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/238","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/238","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1237","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bridge, Candice"]},{"key":"dc:creator","label":"Author","values":["Jones, Kaitlin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z","Summer","2021-08-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Automotive paint analysis; DART-HRMS; FTIR spectroscopy; Py-GC-MS; Forensic techniques","Chemistry","Coatings--Analysis; Paint materials--Analysis; Mass spectrometry--Forensic applications; Gas chromatography--Forensic applications; Coatings--Evaluation"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008187; DP0023541"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/238"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences","Forensic Science"]},{"key":"dc:description.abstract","label":"Abstract","values":["Current techniques used to analyze automotive paint samples include microscopy, fourier – transform infrared (FTIR) spectroscopy, and pyrolysis gas chromatography - mass spectrometry (Py-GC-MS). These techniques are performed in the respective order listed above. Out of the three techniques currently used in this field, the one that has the highest discriminatory power is py-GC-MS; however, this technique is time consuming and destructive toward the sample. One hundred automotive paint samples were analyzed using FTIR, Py-GC-MS and direct analysis in real time-high resolution mass spectrometry (DART-HRMS) to determine how DART-HRMS compared to Py-GC-MS in terms of discriminatory capability. DART-HRMS takes approximately 4 minutes to run a sample while Py-GC-MS takes around 24 minutes per sample. The vast difference in analysis run times between the two techniques could help prevent and/or get rid of current backlogs in forensic trace labs. The clear coat and base coat of automotive paint samples were analyzed using DART-HRMS to compare the different information obtained for the separate layers. The accuracies of the models, based on LDA, were 86.77%, 87.98%, 95.61%, and 98.20% for DART-HRMS (base coat), FTIR, Py-GC-MS, and DART-HRMS (clear coat), respectively. This demonstrates that DART-HRMS can be utilized when analyzing automotive paint samples to achieve a higher discriminatory power while also analyzing samples in a fraction of the time that Py-GC-MS takes."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization of Clear Coat and Base Coat Automotive Paint Analysis Using DART-HRMS and Comparison of FTIR Spectroscopy, Py-GC-MS, and DART-HRMS for Clear Coat Analysis"]}]}],"canonical_facts":{"dc:contributor":["Bridge, Candice"],"dc:creator":["Jones, Kaitlin"],"dc:date.created":["2020-01-01T08:00:00Z","Summer","2021-08-15T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences","Forensic Science"],"dc:description.abstract":["Current techniques used to analyze automotive paint samples include microscopy, fourier – transform infrared (FTIR) spectroscopy, and pyrolysis gas chromatography - mass spectrometry (Py-GC-MS). These techniques are performed in the respective order listed above. Out of the three techniques currently used in this field, the one that has the highest discriminatory power is py-GC-MS; however, this technique is time consuming and destructive toward the sample. One hundred automotive paint samples were analyzed using FTIR, Py-GC-MS and direct analysis in real time-high resolution mass spectrometry (DART-HRMS) to determine how DART-HRMS compared to Py-GC-MS in terms of discriminatory capability. DART-HRMS takes approximately 4 minutes to run a sample while Py-GC-MS takes around 24 minutes per sample. The vast difference in analysis run times between the two techniques could help prevent and/or get rid of current backlogs in forensic trace labs. The clear coat and base coat of automotive paint samples were analyzed using DART-HRMS to compare the different information obtained for the separate layers. The accuracies of the models, based on LDA, were 86.77%, 87.98%, 95.61%, and 98.20% for DART-HRMS (base coat), FTIR, Py-GC-MS, and DART-HRMS (clear coat), respectively. This demonstrates that DART-HRMS can be utilized when analyzing automotive paint samples to achieve a higher discriminatory power while also analyzing samples in a fraction of the time that Py-GC-MS takes."],"dc:format":["application/pdf"],"dc:identifier":["CFE0008187; DP0023541"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/238"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Automotive paint analysis; DART-HRMS; FTIR spectroscopy; Py-GC-MS; Forensic techniques","Chemistry","Coatings--Analysis; Paint materials--Analysis; Mass spectrometry--Forensic applications; Gas chromatography--Forensic applications; Coatings--Evaluation"],"dc:title":["Characterization of Clear Coat and Base Coat Automotive Paint Analysis Using DART-HRMS and Comparison of FTIR Spectroscopy, Py-GC-MS, and DART-HRMS for Clear Coat Analysis"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:40:57Z"}