{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1406"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1406","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"A Computational Biomechanical Model-Based Optimization of Fulcrum Support in Orthosis Enabled Closed Reduction of Developmental Dysplasia of The Hip","abstract":"Hip abduction orthosis devices (HAOD) are used to reduce the hip joint of infants affected by developmental dysplasia of the hip (DDH). HAOD have been successful for mild cases of DDH and ineffective for severe cases. Efforts in understanding the biomechanics of lower limbs have been made to improve the success rate of current treatment methods, especially for Grade IV dislocations (G4). The aim of this dissertation is twofold: first, it proposes the use of a varying fulcrum point (FP) located below the leg to improve DDH treatment; and secondly, it defines the optimal FP (OP) location for a broad spectrum of hip joint configurations. An iterative 3D computational model of a 10-week-old infant was developed using parameters of the femur, pelvis, and lower limb muscles along with their anatomical location. The computational model provides a variety of scenarios of closed reduction and the location of the OP, which is believed to be a key parameter for a successful reduction in severe cases of DDH. The problem is posed as a maximization of an objective function whose independent parameter is the location of the FP constrained to vary over an anatomically feasible range along the femur. For each location of the FP, the model computes resultant forces and evaluates a potential energy function. The OP maximizes the projection of the resultant vector force of the femur over the least energy path to assist in achieving G4 reduction. The results of this study suggest that for the range of the parameters used in the model, G4 reduction can be achieved as the FP reaches the femoral head with the aid of additional external traction forces. Results from this study may be used to customize current orthosis design by using patient-specific parameters, which can be obtained from imaging.","abstract_html":"Hip abduction orthosis devices (HAOD) are used to reduce the hip joint of infants affected by developmental dysplasia of the hip (DDH). HAOD have been successful for mild cases of DDH and ineffective for severe cases. Efforts in understanding the biomechanics of lower limbs have been made to improve the success rate of current treatment methods, especially for Grade IV dislocations (G4). The aim of this dissertation is twofold: first, it proposes the use of a varying fulcrum point (FP) located below the leg to improve DDH treatment; and secondly, it defines the optimal FP (OP) location for a broad spectrum of hip joint configurations. An iterative 3D computational model of a 10-week-old infant was developed using parameters of the femur, pelvis, and lower limb muscles along with their anatomical location. The computational model provides a variety of scenarios of closed reduction and the location of the OP, which is believed to be a key parameter for a successful reduction in severe cases of DDH. The problem is posed as a maximization of an objective function whose independent parameter is the location of the FP constrained to vary over an anatomically feasible range along the femur. For each location of the FP, the model computes resultant forces and evaluates a potential energy function. The OP maximizes the projection of the resultant vector force of the femur over the least energy path to assist in achieving G4 reduction. The results of this study suggest that for the range of the parameters used in the model, G4 reduction can be achieved as the FP reaches the femoral head with the aid of additional external traction forces. Results from this study may be used to customize current orthosis design by using patient-specific parameters, which can be obtained from imaging.","abstract_has_math":false,"creators":["Rose, Christopher"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Kassab, Alain"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:43:13Z","subjects":["Developmental dysplasia; Hip abduction orthosis; Computational modeling; Fulcrum optimization; Closed reduction","Mechanical Engineering","Orthotics and Prosthetics","Orthopedics--Computer simulation; Biomechanics--Mathematical models; Hip joint--Dislocation, Congenital; Orthopedic apparatus--Design; Pediatric orthopedics"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008378; DP0023815"],"render_values":[{"text":"CFE0008378; DP0023815","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/407","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/407","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1406","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kassab, Alain"]},{"key":"dc:creator","label":"Author","values":["Rose, Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2020-01-01T08:00:00Z","Fall","2020-12-15T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Developmental dysplasia; Hip abduction orthosis; Computational modeling; Fulcrum optimization; Closed reduction","Mechanical Engineering","Orthotics and Prosthetics","Orthopedics--Computer simulation; Biomechanics--Mathematical models; Hip joint--Dislocation, Congenital; Orthopedic apparatus--Design; Pediatric orthopedics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008378; DP0023815"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/407"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Hip abduction orthosis devices (HAOD) are used to reduce the hip joint of infants affected by developmental dysplasia of the hip (DDH). HAOD have been successful for mild cases of DDH and ineffective for severe cases. Efforts in understanding the biomechanics of lower limbs have been made to improve the success rate of current treatment methods, especially for Grade IV dislocations (G4). The aim of this dissertation is twofold: first, it proposes the use of a varying fulcrum point (FP) located below the leg to improve DDH treatment; and secondly, it defines the optimal FP (OP) location for a broad spectrum of hip joint configurations. An iterative 3D computational model of a 10-week-old infant was developed using parameters of the femur, pelvis, and lower limb muscles along with their anatomical location. The computational model provides a variety of scenarios of closed reduction and the location of the OP, which is believed to be a key parameter for a successful reduction in severe cases of DDH. The problem is posed as a maximization of an objective function whose independent parameter is the location of the FP constrained to vary over an anatomically feasible range along the femur. For each location of the FP, the model computes resultant forces and evaluates a potential energy function. The OP maximizes the projection of the resultant vector force of the femur over the least energy path to assist in achieving G4 reduction. The results of this study suggest that for the range of the parameters used in the model, G4 reduction can be achieved as the FP reaches the femoral head with the aid of additional external traction forces. Results from this study may be used to customize current orthosis design by using patient-specific parameters, which can be obtained from imaging."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A Computational Biomechanical Model-Based Optimization of Fulcrum Support in Orthosis Enabled Closed Reduction of Developmental Dysplasia of The Hip"]}]}],"canonical_facts":{"dc:contributor":["Kassab, Alain"],"dc:creator":["Rose, Christopher"],"dc:date.created":["2020-01-01T08:00:00Z","Fall","2020-12-15T08:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering"],"dc:description.abstract":["Hip abduction orthosis devices (HAOD) are used to reduce the hip joint of infants affected by developmental dysplasia of the hip (DDH). HAOD have been successful for mild cases of DDH and ineffective for severe cases. Efforts in understanding the biomechanics of lower limbs have been made to improve the success rate of current treatment methods, especially for Grade IV dislocations (G4). The aim of this dissertation is twofold: first, it proposes the use of a varying fulcrum point (FP) located below the leg to improve DDH treatment; and secondly, it defines the optimal FP (OP) location for a broad spectrum of hip joint configurations. An iterative 3D computational model of a 10-week-old infant was developed using parameters of the femur, pelvis, and lower limb muscles along with their anatomical location. The computational model provides a variety of scenarios of closed reduction and the location of the OP, which is believed to be a key parameter for a successful reduction in severe cases of DDH. The problem is posed as a maximization of an objective function whose independent parameter is the location of the FP constrained to vary over an anatomically feasible range along the femur. For each location of the FP, the model computes resultant forces and evaluates a potential energy function. The OP maximizes the projection of the resultant vector force of the femur over the least energy path to assist in achieving G4 reduction. The results of this study suggest that for the range of the parameters used in the model, G4 reduction can be achieved as the FP reaches the femoral head with the aid of additional external traction forces. Results from this study may be used to customize current orthosis design by using patient-specific parameters, which can be obtained from imaging."],"dc:format":["application/pdf"],"dc:identifier":["CFE0008378; DP0023815"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/407"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Developmental dysplasia; Hip abduction orthosis; Computational modeling; Fulcrum optimization; Closed reduction","Mechanical Engineering","Orthotics and Prosthetics","Orthopedics--Computer simulation; Biomechanics--Mathematical models; Hip joint--Dislocation, Congenital; Orthopedic apparatus--Design; Pediatric orthopedics"],"dc:title":["A Computational Biomechanical Model-Based Optimization of Fulcrum Support in Orthosis Enabled Closed Reduction of Developmental Dysplasia of The Hip"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:43:13Z"}