{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1576"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1576","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Mechanical Properties and Spectral Vibrational Response of Si-O-C With and Without Graphene Toughening","abstract":"The mechanical behavior of silicon oxycarbide polymer derived ceramics (SiOC-PDC) without and with a graphene toughening phase was studied under uniaxial compressive load with zero dwell time and with 200 second dwell time step loading in combination with in-situ Raman spectroscopy to determine spectral vibrational response of SiOC under compressive stress. SiOC without and with graphene ceramic samples were produced through the replica templating technique. The compressive strengths of SiOC without and with a graphene toughening phase measured with zero dwell time was determined to be equal to 165.65 (SD 54.21) and 163 (SD 24.2) MPa, respectively, while compressive strengths of the selected ceramics measured with 200 second dwell time step loading was determined to be equal to 228.97 and 186.42 MPa, respectively. Weibull analysis of 27 pure SiOC ceramic samples and 31 SiOC-graphene ceramic composite samples tested with zero dwell time was performed to calculate their probability of failure. Weibull parameters, such as Weibull modulus and characteristic strength, were determined to be equal to m = 3.46 and 190.41 MPa for pure SiOC ceramics and m = 7.71 and 178.73 MPa for SiOC with graphene ceramic composite. In-situ Raman spectroscopy was performed during compression of SiOC without and with a graphene toughening phase dwelled for 200 seconds during step loading, which allowed the collection of Raman spectra of graphitic carbon nanodomains in SiOC at different applied compressive stresses. The properties of the D and G bands of the graphitic nanodomains in SiOC, such as peak intensity, peak area, peak position and FWHM, were analyzed as a function of applied compressive stress. Piezospectroscopic coefficients were then calculated to be equal to 10.994 and -10.269 cm-1/GPa for the G band and 31.538 and 6.341 cm-1/GPa for the D band of pure SiOC and SiOC with a graphene toughening phase, respectively.","abstract_html":"The mechanical behavior of silicon oxycarbide polymer derived ceramics (SiOC-PDC) without and with a graphene toughening phase was studied under uniaxial compressive load with zero dwell time and with 200 second dwell time step loading in combination with in-situ Raman spectroscopy to determine spectral vibrational response of SiOC under compressive stress. SiOC without and with graphene ceramic samples were produced through the replica templating technique. The compressive strengths of SiOC without and with a graphene toughening phase measured with zero dwell time was determined to be equal to 165.65 (SD 54.21) and 163 (SD 24.2) MPa, respectively, while compressive strengths of the selected ceramics measured with 200 second dwell time step loading was determined to be equal to 228.97 and 186.42 MPa, respectively. Weibull analysis of 27 pure SiOC ceramic samples and 31 SiOC-graphene ceramic composite samples tested with zero dwell time was performed to calculate their probability of failure. Weibull parameters, such as Weibull modulus and characteristic strength, were determined to be equal to m = 3.46 and 190.41 MPa for pure SiOC ceramics and m = 7.71 and 178.73 MPa for SiOC with graphene ceramic composite. In-situ Raman spectroscopy was performed during compression of SiOC without and with a graphene toughening phase dwelled for 200 seconds during step loading, which allowed the collection of Raman spectra of graphitic carbon nanodomains in SiOC at different applied compressive stresses. The properties of the D and G bands of the graphitic nanodomains in SiOC, such as peak intensity, peak area, peak position and FWHM, were analyzed as a function of applied compressive stress. Piezospectroscopic coefficients were then calculated to be equal to 10.994 and -10.269 cm-1/GPa for the G band and 31.538 and 6.341 cm-1/GPa for the D band of pure SiOC and SiOC with a graphene toughening phase, respectively.","abstract_has_math":false,"creators":["Vozza, Anthony"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Orlovskaya, Nina"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:43:13Z","subjects":["Silicon oxycarbide; Graphene toughening; Compressive strength; Raman spectroscopy; Weibull analysis","Mechanical Engineering","Ceramic-matrix composites--Mechanical properties; Fiber-reinforced ceramics--Mechanical properties; Composite materials--Mechanical properties; Nanostructured materials--Mechanical properties; Carbon composites--Testing"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008548; DP0024224"],"render_values":[{"text":"CFE0008548; DP0024224","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/577","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/577","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1576","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Orlovskaya, Nina"]},{"key":"dc:creator","label":"Author","values":["Vozza, Anthony"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z","Spring","2021-05-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Silicon oxycarbide; Graphene toughening; Compressive strength; Raman spectroscopy; Weibull analysis","Mechanical Engineering","Ceramic-matrix composites--Mechanical properties; Fiber-reinforced ceramics--Mechanical properties; Composite materials--Mechanical properties; Nanostructured materials--Mechanical properties; Carbon composites--Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008548; DP0024224"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/577"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science in Mechanical Engineering (M.S.M.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering; Mechanical Systems Track"]},{"key":"dc:description.abstract","label":"Abstract","values":["The mechanical behavior of silicon oxycarbide polymer derived ceramics (SiOC-PDC) without and with a graphene toughening phase was studied under uniaxial compressive load with zero dwell time and with 200 second dwell time step loading in combination with in-situ Raman spectroscopy to determine spectral vibrational response of SiOC under compressive stress. SiOC without and with graphene ceramic samples were produced through the replica templating technique. The compressive strengths of SiOC without and with a graphene toughening phase measured with zero dwell time was determined to be equal to 165.65 (SD 54.21) and 163 (SD 24.2) MPa, respectively, while compressive strengths of the selected ceramics measured with 200 second dwell time step loading was determined to be equal to 228.97 and 186.42 MPa, respectively. Weibull analysis of 27 pure SiOC ceramic samples and 31 SiOC-graphene ceramic composite samples tested with zero dwell time was performed to calculate their probability of failure. Weibull parameters, such as Weibull modulus and characteristic strength, were determined to be equal to m = 3.46 and 190.41 MPa for pure SiOC ceramics and m = 7.71 and 178.73 MPa for SiOC with graphene ceramic composite. In-situ Raman spectroscopy was performed during compression of SiOC without and with a graphene toughening phase dwelled for 200 seconds during step loading, which allowed the collection of Raman spectra of graphitic carbon nanodomains in SiOC at different applied compressive stresses. The properties of the D and G bands of the graphitic nanodomains in SiOC, such as peak intensity, peak area, peak position and FWHM, were analyzed as a function of applied compressive stress. Piezospectroscopic coefficients were then calculated to be equal to 10.994 and -10.269 cm-1/GPa for the G band and 31.538 and 6.341 cm-1/GPa for the D band of pure SiOC and SiOC with a graphene toughening phase, respectively."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Mechanical Properties and Spectral Vibrational Response of Si-O-C With and Without Graphene Toughening"]}]}],"canonical_facts":{"dc:contributor":["Orlovskaya, Nina"],"dc:creator":["Vozza, Anthony"],"dc:date.created":["2021-01-01T08:00:00Z","Spring","2021-05-15T07:00:00Z"],"dc:description":["Master of Science in Mechanical Engineering (M.S.M.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Mechanical Engineering; Mechanical Systems Track"],"dc:description.abstract":["The mechanical behavior of silicon oxycarbide polymer derived ceramics (SiOC-PDC) without and with a graphene toughening phase was studied under uniaxial compressive load with zero dwell time and with 200 second dwell time step loading in combination with in-situ Raman spectroscopy to determine spectral vibrational response of SiOC under compressive stress. SiOC without and with graphene ceramic samples were produced through the replica templating technique. The compressive strengths of SiOC without and with a graphene toughening phase measured with zero dwell time was determined to be equal to 165.65 (SD 54.21) and 163 (SD 24.2) MPa, respectively, while compressive strengths of the selected ceramics measured with 200 second dwell time step loading was determined to be equal to 228.97 and 186.42 MPa, respectively. Weibull analysis of 27 pure SiOC ceramic samples and 31 SiOC-graphene ceramic composite samples tested with zero dwell time was performed to calculate their probability of failure. Weibull parameters, such as Weibull modulus and characteristic strength, were determined to be equal to m = 3.46 and 190.41 MPa for pure SiOC ceramics and m = 7.71 and 178.73 MPa for SiOC with graphene ceramic composite. In-situ Raman spectroscopy was performed during compression of SiOC without and with a graphene toughening phase dwelled for 200 seconds during step loading, which allowed the collection of Raman spectra of graphitic carbon nanodomains in SiOC at different applied compressive stresses. The properties of the D and G bands of the graphitic nanodomains in SiOC, such as peak intensity, peak area, peak position and FWHM, were analyzed as a function of applied compressive stress. Piezospectroscopic coefficients were then calculated to be equal to 10.994 and -10.269 cm-1/GPa for the G band and 31.538 and 6.341 cm-1/GPa for the D band of pure SiOC and SiOC with a graphene toughening phase, respectively."],"dc:format":["application/pdf"],"dc:identifier":["CFE0008548; DP0024224"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/577"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Silicon oxycarbide; Graphene toughening; Compressive strength; Raman spectroscopy; Weibull analysis","Mechanical Engineering","Ceramic-matrix composites--Mechanical properties; Fiber-reinforced ceramics--Mechanical properties; Composite materials--Mechanical properties; Nanostructured materials--Mechanical properties; Carbon composites--Testing"],"dc:title":["Mechanical Properties and Spectral Vibrational Response of Si-O-C With and Without Graphene Toughening"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:43:13Z"}