{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-1913"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-1913","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Design of Miniaturized Antipodal Vivaldi Antennas and a Microwave Head Imaging System for the Detection of Blood Clots in the Brain","abstract":"Traditional brain imaging modalities, for example, MRI, CT scan, X-ray, etc. can provide precise and high-resolution images of the brain for diagnosing lesions, tumors or clots inside the brain. However, these modalities require bulky and expensive test setups accessible only at specialized diagnostic centers, and hence may not be suitable or affordable to many patients. Furthermore, the inherent health risks limit the usability of these modalities for frequent monitoring. Microwave imaging is deemed a promising alternative due to its being cost-effective, portable, non-ionizing, non-intrusive. Therefore, this work aims to design an effective microwave head imaging system for the detection of blood clots inside the brain. Two miniaturized antipodal Vivaldi antenna designs are proposed which can provide wideband operation covering the low microwave frequency range (within 1 - 6 GHz) while having electrically small dimensions, directional radiation pattern with reasonable gain, and without requiring immersion in any matching/ coupling liquid. A head imaging system is presented which utilizes a quarter-head scanning approach, to reconstruct four images of the brain by scanning four quarters of the head, using the designed antipodal wideband Vivaldi antenna. A numerical brain model, with and without the presence of blood clot, is simulated using the proposed head-imaging system. At each quarter, the antenna is placed at nine different positions for scanning. The reflected signal at each position is processed and using confocal microwave imaging technique four images of the brain are reconstructed. A comparison is made among the four images in terms of their intensities, for the detection and approximate location of the blood clot inside the brain. The presence of higher intensity regions in any specific quarter of the head demonstrates the presence of a clot and its location and validates the feasibility of the proposed head imaging system using the low frequency wideband Vivaldi antenna.","abstract_html":"Traditional brain imaging modalities, for example, MRI, CT scan, X-ray, etc. can provide precise and high-resolution images of the brain for diagnosing lesions, tumors or clots inside the brain. However, these modalities require bulky and expensive test setups accessible only at specialized diagnostic centers, and hence may not be suitable or affordable to many patients. Furthermore, the inherent health risks limit the usability of these modalities for frequent monitoring. Microwave imaging is deemed a promising alternative due to its being cost-effective, portable, non-ionizing, non-intrusive. Therefore, this work aims to design an effective microwave head imaging system for the detection of blood clots inside the brain. Two miniaturized antipodal Vivaldi antenna designs are proposed which can provide wideband operation covering the low microwave frequency range (within 1 - 6 GHz) while having electrically small dimensions, directional radiation pattern with reasonable gain, and without requiring immersion in any matching/ coupling liquid. A head imaging system is presented which utilizes a quarter-head scanning approach, to reconstruct four images of the brain by scanning four quarters of the head, using the designed antipodal wideband Vivaldi antenna. A numerical brain model, with and without the presence of blood clot, is simulated using the proposed head-imaging system. At each quarter, the antenna is placed at nine different positions for scanning. The reflected signal at each position is processed and using confocal microwave imaging technique four images of the brain are reconstructed. A comparison is made among the four images in terms of their intensities, for the detection and approximate location of the blood clot inside the brain. The presence of higher intensity regions in any specific quarter of the head demonstrates the presence of a clot and its location and validates the feasibility of the proposed head imaging system using the low frequency wideband Vivaldi antenna.","abstract_has_math":false,"creators":["Parveen, Farhana"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Wahid, Parveen"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:42:55Z","subjects":["Microwave imaging; Antipodal Vivaldi antennas; Brain clots detection; Non-invasive imaging; Numerical brain model","Bioimaging and Biomedical Optics","Electrical and Computer Engineering","Microwave imaging in medicine; Imaging systems in medicine--Design; Microwave antennas--Design and construction; Brain--Blood-vessels--Imaging; Imaging systems--Design"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008885; DP0026164"],"render_values":[{"text":"CFE0008885; DP0026164","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/914","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/914","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-1913","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Wahid, Parveen"]},{"key":"dc:creator","label":"Author","values":["Parveen, Farhana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2021-12-01T08:00:00Z","Fall","2021-12-15T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microwave imaging; Antipodal Vivaldi antennas; Brain clots detection; Non-invasive imaging; Numerical brain model","Bioimaging and Biomedical Optics","Electrical and Computer Engineering","Microwave imaging in medicine; Imaging systems in medicine--Design; Microwave antennas--Design and construction; Brain--Blood-vessels--Imaging; Imaging systems--Design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0008885; DP0026164"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/914"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Electrical and Computer Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Electrical Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Traditional brain imaging modalities, for example, MRI, CT scan, X-ray, etc. can provide precise and high-resolution images of the brain for diagnosing lesions, tumors or clots inside the brain. However, these modalities require bulky and expensive test setups accessible only at specialized diagnostic centers, and hence may not be suitable or affordable to many patients. Furthermore, the inherent health risks limit the usability of these modalities for frequent monitoring. Microwave imaging is deemed a promising alternative due to its being cost-effective, portable, non-ionizing, non-intrusive. Therefore, this work aims to design an effective microwave head imaging system for the detection of blood clots inside the brain. Two miniaturized antipodal Vivaldi antenna designs are proposed which can provide wideband operation covering the low microwave frequency range (within 1 - 6 GHz) while having electrically small dimensions, directional radiation pattern with reasonable gain, and without requiring immersion in any matching/ coupling liquid. A head imaging system is presented which utilizes a quarter-head scanning approach, to reconstruct four images of the brain by scanning four quarters of the head, using the designed antipodal wideband Vivaldi antenna. A numerical brain model, with and without the presence of blood clot, is simulated using the proposed head-imaging system. At each quarter, the antenna is placed at nine different positions for scanning. The reflected signal at each position is processed and using confocal microwave imaging technique four images of the brain are reconstructed. A comparison is made among the four images in terms of their intensities, for the detection and approximate location of the blood clot inside the brain. The presence of higher intensity regions in any specific quarter of the head demonstrates the presence of a clot and its location and validates the feasibility of the proposed head imaging system using the low frequency wideband Vivaldi antenna."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design of Miniaturized Antipodal Vivaldi Antennas and a Microwave Head Imaging System for the Detection of Blood Clots in the Brain"]}]}],"canonical_facts":{"dc:contributor":["Wahid, Parveen"],"dc:creator":["Parveen, Farhana"],"dc:date.created":["2021-12-01T08:00:00Z","Fall","2021-12-15T08:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Electrical and Computer Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Electrical Engineering"],"dc:description.abstract":["Traditional brain imaging modalities, for example, MRI, CT scan, X-ray, etc. can provide precise and high-resolution images of the brain for diagnosing lesions, tumors or clots inside the brain. However, these modalities require bulky and expensive test setups accessible only at specialized diagnostic centers, and hence may not be suitable or affordable to many patients. Furthermore, the inherent health risks limit the usability of these modalities for frequent monitoring. Microwave imaging is deemed a promising alternative due to its being cost-effective, portable, non-ionizing, non-intrusive. Therefore, this work aims to design an effective microwave head imaging system for the detection of blood clots inside the brain. Two miniaturized antipodal Vivaldi antenna designs are proposed which can provide wideband operation covering the low microwave frequency range (within 1 - 6 GHz) while having electrically small dimensions, directional radiation pattern with reasonable gain, and without requiring immersion in any matching/ coupling liquid. A head imaging system is presented which utilizes a quarter-head scanning approach, to reconstruct four images of the brain by scanning four quarters of the head, using the designed antipodal wideband Vivaldi antenna. A numerical brain model, with and without the presence of blood clot, is simulated using the proposed head-imaging system. At each quarter, the antenna is placed at nine different positions for scanning. The reflected signal at each position is processed and using confocal microwave imaging technique four images of the brain are reconstructed. A comparison is made among the four images in terms of their intensities, for the detection and approximate location of the blood clot inside the brain. The presence of higher intensity regions in any specific quarter of the head demonstrates the presence of a clot and its location and validates the feasibility of the proposed head imaging system using the low frequency wideband Vivaldi antenna."],"dc:format":["application/pdf"],"dc:identifier":["CFE0008885; DP0026164"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/914"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Microwave imaging; Antipodal Vivaldi antennas; Brain clots detection; Non-invasive imaging; Numerical brain model","Bioimaging and Biomedical Optics","Electrical and Computer Engineering","Microwave imaging in medicine; Imaging systems in medicine--Design; Microwave antennas--Design and construction; Brain--Blood-vessels--Imaging; Imaging systems--Design"],"dc:title":["Design of Miniaturized Antipodal Vivaldi Antennas and a Microwave Head Imaging System for the Detection of Blood Clots in the Brain"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:42:55Z"}