{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-2101"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-2101","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Investigation of Two-Line and Four-Line Chemiluminescence for Equivalence Ratio Mapping of Elevated Pressure Combustion","abstract":"Flame stabilization behavior is experimentally investigated at engine relevant conditions using an optical sensor imaging system. Optical imaging systems can provide insight into local engine behavior as opposed to measurements with devices such as flowmeters. Two facilities are utilized to examine premixed flame combustion stabilized by bluff body flame holders at both atmospheric and elevated pressures. C2* and CH* chemiluminescence signals are recorded on a four-band imaging system to calibrate the sensor intensity ratio of C2*/CH* to the flame equivalence ratio. Tracking this ratio across flame position can provide local information concerning flow disturbances and other combustor instabilities. Several fuels (methane, propane, and liquid Jet-A) are tested to examine the change in chemiluminescence ratios that can be found in industrial applications. The calibrations are obtained across a wide range of equivalence ratios (0.6-1.4) and for pressures of 1 and 5 bar. Methane flames showed very low C2* signal value in lean and stoichiometric flames, resulting in non-monotonically increasing calibration curves. Propane flames had a monotonic calibration curve, attributed to greater C2* signal intensity. The Jet-A-air flames also had non-monotonically increasing calibrations at 1 bar, but a monotonic curve at elevated pressure. These calibrations are then applied to the average C2*/CH* intensity ratio images to yield maps of flame equivalence ratio. Downstream variation in the equivalence ratio of the unconfined facility is attributed to air entrainment, while in the weaker signal is thought to be a function of the local flame properties.","abstract_html":"Flame stabilization behavior is experimentally investigated at engine relevant conditions using an optical sensor imaging system. Optical imaging systems can provide insight into local engine behavior as opposed to measurements with devices such as flowmeters. Two facilities are utilized to examine premixed flame combustion stabilized by bluff body flame holders at both atmospheric and elevated pressures. C2* and CH* chemiluminescence signals are recorded on a four-band imaging system to calibrate the sensor intensity ratio of C2*/CH* to the flame equivalence ratio. Tracking this ratio across flame position can provide local information concerning flow disturbances and other combustor instabilities. Several fuels (methane, propane, and liquid Jet-A) are tested to examine the change in chemiluminescence ratios that can be found in industrial applications. The calibrations are obtained across a wide range of equivalence ratios (0.6-1.4) and for pressures of 1 and 5 bar. Methane flames showed very low C2* signal value in lean and stoichiometric flames, resulting in non-monotonically increasing calibration curves. Propane flames had a monotonic calibration curve, attributed to greater C2* signal intensity. The Jet-A-air flames also had non-monotonically increasing calibrations at 1 bar, but a monotonic curve at elevated pressure. These calibrations are then applied to the average C2*/CH* intensity ratio images to yield maps of flame equivalence ratio. Downstream variation in the equivalence ratio of the unconfined facility is attributed to air entrainment, while in the weaker signal is thought to be a function of the local flame properties.","abstract_has_math":false,"creators":["Tonarely, Michael"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Ahmed, Kareem"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:41:08Z","subjects":["Chemiluminescence; Flame equivalence ratio; Optical imaging; Combustion stability; Fuel comparison","Aeronautical Vehicles","Aerospace Engineering","Combustion--Measurement; Flame monitoring systems; Chemiluminescence--Measurement; Combustion--Research; Internal combustion engines--Combustion--Research"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009073; DP0026406"],"render_values":[{"text":"CFE0009073; DP0026406","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/1102","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/1102","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-2101","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ahmed, Kareem"]},{"key":"dc:creator","label":"Author","values":["Tonarely, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z","Spring","2027-05-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Campus-only Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemiluminescence; Flame equivalence ratio; Optical imaging; Combustion stability; Fuel comparison","Aeronautical Vehicles","Aerospace Engineering","Combustion--Measurement; Flame monitoring systems; Chemiluminescence--Measurement; Combustion--Research; Internal combustion engines--Combustion--Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009073; DP0026406"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/1102"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science in Environmental Engineering (M.S.Env.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Aerospace Engineering; Thermofluid Aerodynamic Systems"]},{"key":"dc:description.abstract","label":"Abstract","values":["Flame stabilization behavior is experimentally investigated at engine relevant conditions using an optical sensor imaging system. Optical imaging systems can provide insight into local engine behavior as opposed to measurements with devices such as flowmeters. Two facilities are utilized to examine premixed flame combustion stabilized by bluff body flame holders at both atmospheric and elevated pressures. C2* and CH* chemiluminescence signals are recorded on a four-band imaging system to calibrate the sensor intensity ratio of C2*/CH* to the flame equivalence ratio. Tracking this ratio across flame position can provide local information concerning flow disturbances and other combustor instabilities. Several fuels (methane, propane, and liquid Jet-A) are tested to examine the change in chemiluminescence ratios that can be found in industrial applications. The calibrations are obtained across a wide range of equivalence ratios (0.6-1.4) and for pressures of 1 and 5 bar. Methane flames showed very low C2* signal value in lean and stoichiometric flames, resulting in non-monotonically increasing calibration curves. Propane flames had a monotonic calibration curve, attributed to greater C2* signal intensity. The Jet-A-air flames also had non-monotonically increasing calibrations at 1 bar, but a monotonic curve at elevated pressure. These calibrations are then applied to the average C2*/CH* intensity ratio images to yield maps of flame equivalence ratio. Downstream variation in the equivalence ratio of the unconfined facility is attributed to air entrainment, while in the weaker signal is thought to be a function of the local flame properties."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of Two-Line and Four-Line Chemiluminescence for Equivalence Ratio Mapping of Elevated Pressure Combustion"]}]}],"canonical_facts":{"dc:contributor":["Ahmed, Kareem"],"dc:creator":["Tonarely, Michael"],"dc:date.created":["2022-01-01T08:00:00Z","Spring","2027-05-15T07:00:00Z"],"dc:description":["Master of Science in Environmental Engineering (M.S.Env.E.)","Mechanical and Aerospace Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Aerospace Engineering; Thermofluid Aerodynamic Systems"],"dc:description.abstract":["Flame stabilization behavior is experimentally investigated at engine relevant conditions using an optical sensor imaging system. Optical imaging systems can provide insight into local engine behavior as opposed to measurements with devices such as flowmeters. Two facilities are utilized to examine premixed flame combustion stabilized by bluff body flame holders at both atmospheric and elevated pressures. C2* and CH* chemiluminescence signals are recorded on a four-band imaging system to calibrate the sensor intensity ratio of C2*/CH* to the flame equivalence ratio. Tracking this ratio across flame position can provide local information concerning flow disturbances and other combustor instabilities. Several fuels (methane, propane, and liquid Jet-A) are tested to examine the change in chemiluminescence ratios that can be found in industrial applications. The calibrations are obtained across a wide range of equivalence ratios (0.6-1.4) and for pressures of 1 and 5 bar. Methane flames showed very low C2* signal value in lean and stoichiometric flames, resulting in non-monotonically increasing calibration curves. Propane flames had a monotonic calibration curve, attributed to greater C2* signal intensity. The Jet-A-air flames also had non-monotonically increasing calibrations at 1 bar, but a monotonic curve at elevated pressure. These calibrations are then applied to the average C2*/CH* intensity ratio images to yield maps of flame equivalence ratio. Downstream variation in the equivalence ratio of the unconfined facility is attributed to air entrainment, while in the weaker signal is thought to be a function of the local flame properties."],"dc:format":["application/pdf"],"dc:identifier":["CFE0009073; DP0026406"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/1102"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Chemiluminescence; Flame equivalence ratio; Optical imaging; Combustion stability; Fuel comparison","Aeronautical Vehicles","Aerospace Engineering","Combustion--Measurement; Flame monitoring systems; Chemiluminescence--Measurement; Combustion--Research; Internal combustion engines--Combustion--Research"],"dc:title":["Investigation of Two-Line and Four-Line Chemiluminescence for Equivalence Ratio Mapping of Elevated Pressure Combustion"],"dc:type":["Masters Thesis (Campus-only Access)"]},"updated_at":"2026-11-19T09:41:08Z"}