{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-2318"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-2318","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Analysis of Sexual Lubricants as a Form of Trace Evidence for Sexual Assault Cases","abstract":"A major gap in sexual assault casework is demonstrated when DNA is not recovered. Oftentimes, if DNA evidence is not present on the collection swabs, the sexual assault kit (SAK) is not further analyzed. Due to the \"CSI effect,\" DNA is commonly understood as highly identifiable evidence, potentially leading to increased condom usage to eliminate or reduce DNA transfer during a sexual assault. Therefore, the analysis of condoms and sexual lubricants is pertinent. The purpose of this research is to develop analytical protocols to potentially connect unknown substances recovered in a SAK to known lubricant reference samples. Sexual lubricants were analyzed using Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry, and direct analysis in real time-high resolution mass spectrometry. Analytical protocols were developed using 162 sexual lubricants comprised of bottled lubricants, condoms, and personal hygiene products. A statistical model was developed from 112 of the samples using hierarchical cluster analysis (HCA), principal component analysis (PCA), and linear discriminant analysis (LDA) to determine appropriate sample groupings that resulted in at least 97% accurate classification for each instrument. Assigned truth classes for the remaining 50 samples were developed using Pearson correlation coefficients (PCCs) to predict classification accuracy for unknown samples. The FTIR data resulted in a 96% accurate prediction, 54% for GC-MS, and 42% for DART-HRMS, showing the need for expansion of the sample set in future analysis. Potential storage conditions of SAK swabs were evaluated using PCCs to identify optimal swab storage conditions, which was determined to be a humidity-controlled environment around 22 °C. Then, post-coital swab samples from volunteers using an unknown condom were analyzed using the developed protocols. The data was analyzed using PCC, PCA, and LDA to compare the classification to the \"ground truth\" of the sample to determine potential applications of this research in SAK analysis.","abstract_html":"A major gap in sexual assault casework is demonstrated when DNA is not recovered. Oftentimes, if DNA evidence is not present on the collection swabs, the sexual assault kit (SAK) is not further analyzed. Due to the &quot;CSI effect,&quot; DNA is commonly understood as highly identifiable evidence, potentially leading to increased condom usage to eliminate or reduce DNA transfer during a sexual assault. Therefore, the analysis of condoms and sexual lubricants is pertinent. The purpose of this research is to develop analytical protocols to potentially connect unknown substances recovered in a SAK to known lubricant reference samples. Sexual lubricants were analyzed using Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry, and direct analysis in real time-high resolution mass spectrometry. Analytical protocols were developed using 162 sexual lubricants comprised of bottled lubricants, condoms, and personal hygiene products. A statistical model was developed from 112 of the samples using hierarchical cluster analysis (HCA), principal component analysis (PCA), and linear discriminant analysis (LDA) to determine appropriate sample groupings that resulted in at least 97% accurate classification for each instrument. Assigned truth classes for the remaining 50 samples were developed using Pearson correlation coefficients (PCCs) to predict classification accuracy for unknown samples. The FTIR data resulted in a 96% accurate prediction, 54% for GC-MS, and 42% for DART-HRMS, showing the need for expansion of the sample set in future analysis. Potential storage conditions of SAK swabs were evaluated using PCCs to identify optimal swab storage conditions, which was determined to be a humidity-controlled environment around 22 °C. Then, post-coital swab samples from volunteers using an unknown condom were analyzed using the developed protocols. The data was analyzed using PCC, PCA, and LDA to compare the classification to the &quot;ground truth&quot; of the sample to determine potential applications of this research in SAK analysis.","abstract_has_math":false,"creators":["Baumgarten, Brooke"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Bridge, Candice"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:42:15Z","subjects":["Sexual assault; Forensic analysis; Lubricant identification; Analytical protocols; DNA evidence","Medicinal-Pharmaceutical Chemistry","Lubrication and lubricants--Analysis; Sex crimes--Research; Forensic sciences--Experiments; Gas chromatography--Forensic applications; Mass spectrometry--Forensic applications"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009290; DP0026894"],"render_values":[{"text":"CFE0009290; DP0026894","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/1319","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/1319","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-2318","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bridge, Candice"]},{"key":"dc:creator","label":"Author","values":["Baumgarten, Brooke"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z","Fall","2022-06-15T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Doctoral Dissertation (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Sexual assault; Forensic analysis; Lubricant identification; Analytical protocols; DNA evidence","Medicinal-Pharmaceutical Chemistry","Lubrication and lubricants--Analysis; Sex crimes--Research; Forensic sciences--Experiments; Gas chromatography--Forensic applications; Mass spectrometry--Forensic applications"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009290; DP0026894"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/1319"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"]},{"key":"dc:description.abstract","label":"Abstract","values":["A major gap in sexual assault casework is demonstrated when DNA is not recovered. Oftentimes, if DNA evidence is not present on the collection swabs, the sexual assault kit (SAK) is not further analyzed. Due to the \"CSI effect,\" DNA is commonly understood as highly identifiable evidence, potentially leading to increased condom usage to eliminate or reduce DNA transfer during a sexual assault. Therefore, the analysis of condoms and sexual lubricants is pertinent. The purpose of this research is to develop analytical protocols to potentially connect unknown substances recovered in a SAK to known lubricant reference samples. Sexual lubricants were analyzed using Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry, and direct analysis in real time-high resolution mass spectrometry. Analytical protocols were developed using 162 sexual lubricants comprised of bottled lubricants, condoms, and personal hygiene products. A statistical model was developed from 112 of the samples using hierarchical cluster analysis (HCA), principal component analysis (PCA), and linear discriminant analysis (LDA) to determine appropriate sample groupings that resulted in at least 97% accurate classification for each instrument. Assigned truth classes for the remaining 50 samples were developed using Pearson correlation coefficients (PCCs) to predict classification accuracy for unknown samples. The FTIR data resulted in a 96% accurate prediction, 54% for GC-MS, and 42% for DART-HRMS, showing the need for expansion of the sample set in future analysis. Potential storage conditions of SAK swabs were evaluated using PCCs to identify optimal swab storage conditions, which was determined to be a humidity-controlled environment around 22 °C. Then, post-coital swab samples from volunteers using an unknown condom were analyzed using the developed protocols. The data was analyzed using PCC, PCA, and LDA to compare the classification to the \"ground truth\" of the sample to determine potential applications of this research in SAK analysis."]},{"key":"dc:title","label":"Title","values":["Analysis of Sexual Lubricants as a Form of Trace Evidence for Sexual Assault Cases"]}]}],"canonical_facts":{"dc:contributor":["Bridge, Candice"],"dc:creator":["Baumgarten, Brooke"],"dc:date.created":["2021-01-01T08:00:00Z","Fall","2022-06-15T07:00:00Z"],"dc:description":["Doctor of Philosophy (Ph.D.)","Chemistry","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Sciences"],"dc:description.abstract":["A major gap in sexual assault casework is demonstrated when DNA is not recovered. Oftentimes, if DNA evidence is not present on the collection swabs, the sexual assault kit (SAK) is not further analyzed. Due to the \"CSI effect,\" DNA is commonly understood as highly identifiable evidence, potentially leading to increased condom usage to eliminate or reduce DNA transfer during a sexual assault. Therefore, the analysis of condoms and sexual lubricants is pertinent. The purpose of this research is to develop analytical protocols to potentially connect unknown substances recovered in a SAK to known lubricant reference samples. Sexual lubricants were analyzed using Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry, and direct analysis in real time-high resolution mass spectrometry. Analytical protocols were developed using 162 sexual lubricants comprised of bottled lubricants, condoms, and personal hygiene products. A statistical model was developed from 112 of the samples using hierarchical cluster analysis (HCA), principal component analysis (PCA), and linear discriminant analysis (LDA) to determine appropriate sample groupings that resulted in at least 97% accurate classification for each instrument. Assigned truth classes for the remaining 50 samples were developed using Pearson correlation coefficients (PCCs) to predict classification accuracy for unknown samples. The FTIR data resulted in a 96% accurate prediction, 54% for GC-MS, and 42% for DART-HRMS, showing the need for expansion of the sample set in future analysis. Potential storage conditions of SAK swabs were evaluated using PCCs to identify optimal swab storage conditions, which was determined to be a humidity-controlled environment around 22 °C. Then, post-coital swab samples from volunteers using an unknown condom were analyzed using the developed protocols. The data was analyzed using PCC, PCA, and LDA to compare the classification to the \"ground truth\" of the sample to determine potential applications of this research in SAK analysis."],"dc:identifier":["CFE0009290; DP0026894"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/1319"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Sexual assault; Forensic analysis; Lubricant identification; Analytical protocols; DNA evidence","Medicinal-Pharmaceutical Chemistry","Lubrication and lubricants--Analysis; Sex crimes--Research; Forensic sciences--Experiments; Gas chromatography--Forensic applications; Mass spectrometry--Forensic applications"],"dc:title":["Analysis of Sexual Lubricants as a Form of Trace Evidence for Sexual Assault Cases"],"dc:type":["Doctoral Dissertation (Open Access)"]},"updated_at":"2026-11-19T09:42:15Z"}