{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2020-2818"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2020-2818","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Performance Comparison of Low-Cost Sensors Across Six Cities of Continental United States","abstract":"In the field of air quality measurement, low-cost sensors have been extensively used for capturing high-resolution spatial and temporal pollutant concentrations. However, data accuracy and the impact of environmental conditions particularly temperature and relative humidity, remain a significant issue. Careful sensor calibrations against reference instruments are necessary for ensuring data accuracy and validity. This study investigated the effectiveness of multiple calibration methodologies (linear calibration, 3rd order polynomial calibration, and Random Forest, RF) for low-cost air quality sensor calibration across six cities (Atlanta, Portland, Riverside, Sacramento, New York City, and Phoenix) in the United States. The data for this study is collected from April 2019 to April 2020 in the corresponding cities. The study showed that the local calibration provides better accuracy than adopting calibration equation developed for other regions across all the models tested. The potential reasons could be that different cities may have different pollution source combinations, which may result in varying types and concentration levels of interfering gas. Different weather conditions will also contribute to such results, as parameters especially temperature and relative humidity are known to impact the performance of low-cost sensors. Additionally, if included CO signal in the calibration models of NO2 and O3, model performances are found to increases across all the cities. Low-cost CO sensor is known to general perform better and has better long-term stability than their NO2 and O3 sensor counterparts. Results of this thesis contribute to better understanding on low-cost air pollutant sensor deployment and calibration techniques.","abstract_html":"In the field of air quality measurement, low-cost sensors have been extensively used for capturing high-resolution spatial and temporal pollutant concentrations. However, data accuracy and the impact of environmental conditions particularly temperature and relative humidity, remain a significant issue. Careful sensor calibrations against reference instruments are necessary for ensuring data accuracy and validity. This study investigated the effectiveness of multiple calibration methodologies (linear calibration, 3rd order polynomial calibration, and Random Forest, RF) for low-cost air quality sensor calibration across six cities (Atlanta, Portland, Riverside, Sacramento, New York City, and Phoenix) in the United States. The data for this study is collected from April 2019 to April 2020 in the corresponding cities. The study showed that the local calibration provides better accuracy than adopting calibration equation developed for other regions across all the models tested. The potential reasons could be that different cities may have different pollution source combinations, which may result in varying types and concentration levels of interfering gas. Different weather conditions will also contribute to such results, as parameters especially temperature and relative humidity are known to impact the performance of low-cost sensors. Additionally, if included CO signal in the calibration models of NO2 and O3, model performances are found to increases across all the cities. Low-cost CO sensor is known to general perform better and has better long-term stability than their NO2 and O3 sensor counterparts. Results of this thesis contribute to better understanding on low-cost air pollutant sensor deployment and calibration techniques.","abstract_has_math":false,"creators":["Hasan, Md Hasibul"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Yu, Haofei"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:42:44Z","subjects":["Low-cost sensors; Air quality calibration; Pollutant concentrations; Environmental conditions; Data accuracy","Environmental Engineering","Air--Pollution--Measurement--Methodology; Air quality--Research; Air--Pollution--Measurement--Statistical methods; Air--Pollution--Measurement; Air quality management--Research"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009735; DP0027843"],"render_values":[{"text":"CFE0009735; DP0027843","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2020/1819","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2020/1819","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2020-2818","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Yu, Haofei"]},{"key":"dc:creator","label":"Author","values":["Hasan, Md Hasibul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2023-08-15T07:00:00Z","Summer"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Low-cost sensors; Air quality calibration; Pollutant concentrations; Environmental conditions; Data accuracy","Environmental Engineering","Air--Pollution--Measurement--Methodology; Air quality--Research; Air--Pollution--Measurement--Statistical methods; Air--Pollution--Measurement; Air quality management--Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["CFE0009735; DP0027843"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2020/1819"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science in Environmental Engineering (M.S.Env.E.)","Civil, Environmental, and Construction Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Environmental Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["In the field of air quality measurement, low-cost sensors have been extensively used for capturing high-resolution spatial and temporal pollutant concentrations. However, data accuracy and the impact of environmental conditions particularly temperature and relative humidity, remain a significant issue. Careful sensor calibrations against reference instruments are necessary for ensuring data accuracy and validity. This study investigated the effectiveness of multiple calibration methodologies (linear calibration, 3rd order polynomial calibration, and Random Forest, RF) for low-cost air quality sensor calibration across six cities (Atlanta, Portland, Riverside, Sacramento, New York City, and Phoenix) in the United States. The data for this study is collected from April 2019 to April 2020 in the corresponding cities. The study showed that the local calibration provides better accuracy than adopting calibration equation developed for other regions across all the models tested. The potential reasons could be that different cities may have different pollution source combinations, which may result in varying types and concentration levels of interfering gas. Different weather conditions will also contribute to such results, as parameters especially temperature and relative humidity are known to impact the performance of low-cost sensors. Additionally, if included CO signal in the calibration models of NO2 and O3, model performances are found to increases across all the cities. Low-cost CO sensor is known to general perform better and has better long-term stability than their NO2 and O3 sensor counterparts. Results of this thesis contribute to better understanding on low-cost air pollutant sensor deployment and calibration techniques."]},{"key":"dc:title","label":"Title","values":["Performance Comparison of Low-Cost Sensors Across Six Cities of Continental United States"]}]}],"canonical_facts":{"dc:contributor":["Yu, Haofei"],"dc:creator":["Hasan, Md Hasibul"],"dc:date.created":["2023-08-15T07:00:00Z","Summer"],"dc:description":["Master of Science in Environmental Engineering (M.S.Env.E.)","Civil, Environmental, and Construction Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering and Computer Science","Environmental Engineering"],"dc:description.abstract":["In the field of air quality measurement, low-cost sensors have been extensively used for capturing high-resolution spatial and temporal pollutant concentrations. However, data accuracy and the impact of environmental conditions particularly temperature and relative humidity, remain a significant issue. Careful sensor calibrations against reference instruments are necessary for ensuring data accuracy and validity. This study investigated the effectiveness of multiple calibration methodologies (linear calibration, 3rd order polynomial calibration, and Random Forest, RF) for low-cost air quality sensor calibration across six cities (Atlanta, Portland, Riverside, Sacramento, New York City, and Phoenix) in the United States. The data for this study is collected from April 2019 to April 2020 in the corresponding cities. The study showed that the local calibration provides better accuracy than adopting calibration equation developed for other regions across all the models tested. The potential reasons could be that different cities may have different pollution source combinations, which may result in varying types and concentration levels of interfering gas. Different weather conditions will also contribute to such results, as parameters especially temperature and relative humidity are known to impact the performance of low-cost sensors. Additionally, if included CO signal in the calibration models of NO2 and O3, model performances are found to increases across all the cities. Low-cost CO sensor is known to general perform better and has better long-term stability than their NO2 and O3 sensor counterparts. Results of this thesis contribute to better understanding on low-cost air pollutant sensor deployment and calibration techniques."],"dc:identifier":["CFE0009735; DP0027843"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2020/1819"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:subject":["Low-cost sensors; Air quality calibration; Pollutant concentrations; Environmental conditions; Data accuracy","Environmental Engineering","Air--Pollution--Measurement--Methodology; Air quality--Research; Air--Pollution--Measurement--Statistical methods; Air--Pollution--Measurement; Air quality management--Research"],"dc:title":["Performance Comparison of Low-Cost Sensors Across Six Cities of Continental United States"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:42:44Z"}