{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2023-1155"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2023-1155","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Enhancing oil-in-water Emulsified Bildgwater Treatment Using Electric Field Forward Osmosis (EFFO)","abstract":"Bilgewater discharge needs to meet the existing regulations with an oil concentration of less than 15 ppm. Among many treatment options, forward osmosis (FO) can be an economic-environmental method utilizing an osmotic pressure gradient between feed solution (FS) and draw solution (DS) which are separated via a semipermeable membrane. However, FO membrane foundling is still challenging. The main objective of this study was to evaluate the effect of electric field forward osmosis (EFFO) to mitigate membrane fouling and thus improve oil-in-water emulsion separation. Standard bilge mix (SBM) was used as representative bilgewater and mineral oil (MO) was used as control. Two different surfactants/detergents, sodium dodecyl sulfate (SDS) as an anionic surfactant and Type 1 as a non-ionic cleaner, were selected for 36 hours of EFFO operation (0, -0.1, and -1.0 V of electric field). 1% MO+SDS at -0.1 and -1.0 V improved the water flux (Jw) by approximately 12.1% to 52.6% compared to FO-only mode (0 V), showing that the negative electric field effectively increased Jw in the presence of anionic surfactant, unlike Type 1 emulsion FO. 1% SBM+SDS emulsion FO at -0.1 and -1.0 V also improved Jw by approximately 26.3% to 48.6% compared to FO-only mode (0 V). The results found that the electric field may play a significant role in mitigating flux decrease caused by the unknown oil additive in SBM, however, increasing the electric potential did not increase Jw recovery for 1%SBM+SDS. Reverse salt flux (RSF) (Js) was monitored during the experiments and the effect of surfactant/detergent was also evaluated by determining Js/Jw (g L-1). During the tests, the physical cleaning only could recover Jw for every cycle. This study demonstrated the feasibility of employing an electric field to mitigate fouling and improve the water flux inherent in traditional FO systems.","abstract_html":"Bilgewater discharge needs to meet the existing regulations with an oil concentration of less than 15 ppm. Among many treatment options, forward osmosis (FO) can be an economic-environmental method utilizing an osmotic pressure gradient between feed solution (FS) and draw solution (DS) which are separated via a semipermeable membrane. However, FO membrane foundling is still challenging. The main objective of this study was to evaluate the effect of electric field forward osmosis (EFFO) to mitigate membrane fouling and thus improve oil-in-water emulsion separation. Standard bilge mix (SBM) was used as representative bilgewater and mineral oil (MO) was used as control. Two different surfactants/detergents, sodium dodecyl sulfate (SDS) as an anionic surfactant and Type 1 as a non-ionic cleaner, were selected for 36 hours of EFFO operation (0, -0.1, and -1.0 V of electric field). 1% MO+SDS at -0.1 and -1.0 V improved the water flux (Jw) by approximately 12.1% to 52.6% compared to FO-only mode (0 V), showing that the negative electric field effectively increased Jw in the presence of anionic surfactant, unlike Type 1 emulsion FO. 1% SBM+SDS emulsion FO at -0.1 and -1.0 V also improved Jw by approximately 26.3% to 48.6% compared to FO-only mode (0 V). The results found that the electric field may play a significant role in mitigating flux decrease caused by the unknown oil additive in SBM, however, increasing the electric potential did not increase Jw recovery for 1%SBM+SDS. Reverse salt flux (RSF) (Js) was monitored during the experiments and the effect of surfactant/detergent was also evaluated by determining Js/Jw (g L-1). During the tests, the physical cleaning only could recover Jw for every cycle. This study demonstrated the feasibility of employing an electric field to mitigate fouling and improve the water flux inherent in traditional FO systems.","abstract_has_math":false,"creators":["Krikorian, Nareg"],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Lee, Woo Hyoung"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:40:01Z","subjects":["bilgewater","electric field","Electric field forward osmosis (EFFO)","emulsion","Forward Osmosis (FO)","fouling","reverse salt flux","water flux"],"languages":["English"],"rights":["In copyright"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2023/449","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2023/449","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2023-1155","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Lee, Woo Hyoung"]},{"key":"dc:creator","label":"Author","values":["Krikorian, Nareg"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z","Spring","2024-11-15T08:00:00Z"]},{"key":"dc:relation","label":"Dc Relation","values":["Orlando (Main) Campus"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bilgewater","electric field","Electric field forward osmosis (EFFO)","emulsion","Forward Osmosis (FO)","fouling","reverse salt flux","water flux"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["In copyright"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2023/449"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science in Environmental Engineering (M.S.Env.E.)","Civil, Environmental and Construction Engineering","College of Engineering and Computer Science","Environmental Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Bilgewater discharge needs to meet the existing regulations with an oil concentration of less than 15 ppm. Among many treatment options, forward osmosis (FO) can be an economic-environmental method utilizing an osmotic pressure gradient between feed solution (FS) and draw solution (DS) which are separated via a semipermeable membrane. However, FO membrane foundling is still challenging. The main objective of this study was to evaluate the effect of electric field forward osmosis (EFFO) to mitigate membrane fouling and thus improve oil-in-water emulsion separation. Standard bilge mix (SBM) was used as representative bilgewater and mineral oil (MO) was used as control. Two different surfactants/detergents, sodium dodecyl sulfate (SDS) as an anionic surfactant and Type 1 as a non-ionic cleaner, were selected for 36 hours of EFFO operation (0, -0.1, and -1.0 V of electric field). 1% MO+SDS at -0.1 and -1.0 V improved the water flux (Jw) by approximately 12.1% to 52.6% compared to FO-only mode (0 V), showing that the negative electric field effectively increased Jw in the presence of anionic surfactant, unlike Type 1 emulsion FO. 1% SBM+SDS emulsion FO at -0.1 and -1.0 V also improved Jw by approximately 26.3% to 48.6% compared to FO-only mode (0 V). The results found that the electric field may play a significant role in mitigating flux decrease caused by the unknown oil additive in SBM, however, increasing the electric potential did not increase Jw recovery for 1%SBM+SDS. Reverse salt flux (RSF) (Js) was monitored during the experiments and the effect of surfactant/detergent was also evaluated by determining Js/Jw (g L-1). During the tests, the physical cleaning only could recover Jw for every cycle. This study demonstrated the feasibility of employing an electric field to mitigate fouling and improve the water flux inherent in traditional FO systems."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Enhancing oil-in-water Emulsified Bildgwater Treatment Using Electric Field Forward Osmosis (EFFO)"]}]}],"canonical_facts":{"dc:contributor":["Lee, Woo Hyoung"],"dc:creator":["Krikorian, Nareg"],"dc:date.created":["2024-01-01T08:00:00Z","Spring","2024-11-15T08:00:00Z"],"dc:description":["Master of Science in Environmental Engineering (M.S.Env.E.)","Civil, Environmental and Construction Engineering","College of Engineering and Computer Science","Environmental Engineering"],"dc:description.abstract":["Bilgewater discharge needs to meet the existing regulations with an oil concentration of less than 15 ppm. Among many treatment options, forward osmosis (FO) can be an economic-environmental method utilizing an osmotic pressure gradient between feed solution (FS) and draw solution (DS) which are separated via a semipermeable membrane. However, FO membrane foundling is still challenging. The main objective of this study was to evaluate the effect of electric field forward osmosis (EFFO) to mitigate membrane fouling and thus improve oil-in-water emulsion separation. Standard bilge mix (SBM) was used as representative bilgewater and mineral oil (MO) was used as control. Two different surfactants/detergents, sodium dodecyl sulfate (SDS) as an anionic surfactant and Type 1 as a non-ionic cleaner, were selected for 36 hours of EFFO operation (0, -0.1, and -1.0 V of electric field). 1% MO+SDS at -0.1 and -1.0 V improved the water flux (Jw) by approximately 12.1% to 52.6% compared to FO-only mode (0 V), showing that the negative electric field effectively increased Jw in the presence of anionic surfactant, unlike Type 1 emulsion FO. 1% SBM+SDS emulsion FO at -0.1 and -1.0 V also improved Jw by approximately 26.3% to 48.6% compared to FO-only mode (0 V). The results found that the electric field may play a significant role in mitigating flux decrease caused by the unknown oil additive in SBM, however, increasing the electric potential did not increase Jw recovery for 1%SBM+SDS. Reverse salt flux (RSF) (Js) was monitored during the experiments and the effect of surfactant/detergent was also evaluated by determining Js/Jw (g L-1). During the tests, the physical cleaning only could recover Jw for every cycle. This study demonstrated the feasibility of employing an electric field to mitigate fouling and improve the water flux inherent in traditional FO systems."],"dc:format":["application/pdf"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2023/449"],"dc:language":["English"],"dc:relation":["Orlando (Main) Campus"],"dc:rights":["In copyright"],"dc:subject":["bilgewater","electric field","Electric field forward osmosis (EFFO)","emulsion","Forward Osmosis (FO)","fouling","reverse salt flux","water flux"],"dc:title":["Enhancing oil-in-water Emulsified Bildgwater Treatment Using Electric Field Forward Osmosis (EFFO)"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-19T09:40:01Z"}