{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2023-1488"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2023-1488","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Expanding the Capabilities of 3d Microelectrodes Arrays with A Multi-Material Palette and A 6-Well Flex Circuit System","abstract":"In this thesis we identify device (3D Microelectrode Arrays – 3D MEAs)/system (commercial electronics interface) issues preventing the scaling up of the world’s first in vitro model of afferent synaptic signaling in the spinal cord and develop a potential solution involving spin cast insulation and micromilled/microdrilled/microsoldered/flex circuit integrated 6-well interface board with connectors for analyzing up to six 3D MEAs simultaneously at one time. These novel advances can scale experimentation in the development of new treatments, pharmacological responses, and other electrophysiological discoveries for neurological disorders. In addition, we report on a multi-material palette towards the microfabrication of the aforementioned 3D Microelectrodes Arrays for integration with a variety of 3D electrogenic Microphysiological Systems (MPS) beyond the afferent synaptic model. The goal of this part of the thesis was to fabricate 3D MEAs with six microelectrodes by utilizing materials such as polycarbonate (PC), polymethyl methacrylate (PMMA), and polysulfone (PS). We created a reliable microfabrication process by combining laser micromachining, laser-induced breakdown spectroscopy (LIBS), 3D needle assembly, SU-8 coatings and micromilling/ microdrilling techniques. The 3D MEAs demonstrate impedance characteristics similar to commercial MEAs. Additionally, all material combinations showed outstanding transparency and biocompatibility for applicability in 3D neuronal and cardiac studies.","abstract_html":"In this thesis we identify device (3D Microelectrode Arrays – 3D MEAs)/system (commercial electronics interface) issues preventing the scaling up of the world’s first in vitro model of afferent synaptic signaling in the spinal cord and develop a potential solution involving spin cast insulation and micromilled/microdrilled/microsoldered/flex circuit integrated 6-well interface board with connectors for analyzing up to six 3D MEAs simultaneously at one time. These novel advances can scale experimentation in the development of new treatments, pharmacological responses, and other electrophysiological discoveries for neurological disorders. In addition, we report on a multi-material palette towards the microfabrication of the aforementioned 3D Microelectrodes Arrays for integration with a variety of 3D electrogenic Microphysiological Systems (MPS) beyond the afferent synaptic model. The goal of this part of the thesis was to fabricate 3D MEAs with six microelectrodes by utilizing materials such as polycarbonate (PC), polymethyl methacrylate (PMMA), and polysulfone (PS). We created a reliable microfabrication process by combining laser micromachining, laser-induced breakdown spectroscopy (LIBS), 3D needle assembly, SU-8 coatings and micromilling/ microdrilling techniques. The 3D MEAs demonstrate impedance characteristics similar to commercial MEAs. Additionally, all material combinations showed outstanding transparency and biocompatibility for applicability in 3D neuronal and cardiac studies.","abstract_has_math":false,"creators":["Cepeda Torres, Omar S."],"institution":null,"degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Rajaraman, Swaminathan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:39:51Z","subjects":["Hybrid-Microfabrication 3D-Microelectrode-Arrays 3D-Electrogenic-Microphysiological-Systems 6-Well-Interface Flex-Circuit-Board Biocompatibility"],"languages":["English"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0028487"],"render_values":[{"text":"DP0028487","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2023/282","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2023/282","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2023-1488","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Rajaraman, Swaminathan"]},{"key":"dc:creator","label":"Author","values":["Cepeda Torres, Omar S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z","Summer","2025-08-15T07:00:00Z"]},{"key":"dc:relation","label":"Dc Relation","values":["Orlando (Main) Campus"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Campus-only Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hybrid-Microfabrication 3D-Microelectrode-Arrays 3D-Electrogenic-Microphysiological-Systems 6-Well-Interface Flex-Circuit-Board Biocompatibility"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0028487"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2023/282"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Nanoscience and Technology Center","College of Graduate Studies","Nanotechnology"]},{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis we identify device (3D Microelectrode Arrays – 3D MEAs)/system (commercial electronics interface) issues preventing the scaling up of the world’s first in vitro model of afferent synaptic signaling in the spinal cord and develop a potential solution involving spin cast insulation and micromilled/microdrilled/microsoldered/flex circuit integrated 6-well interface board with connectors for analyzing up to six 3D MEAs simultaneously at one time. These novel advances can scale experimentation in the development of new treatments, pharmacological responses, and other electrophysiological discoveries for neurological disorders. In addition, we report on a multi-material palette towards the microfabrication of the aforementioned 3D Microelectrodes Arrays for integration with a variety of 3D electrogenic Microphysiological Systems (MPS) beyond the afferent synaptic model. The goal of this part of the thesis was to fabricate 3D MEAs with six microelectrodes by utilizing materials such as polycarbonate (PC), polymethyl methacrylate (PMMA), and polysulfone (PS). We created a reliable microfabrication process by combining laser micromachining, laser-induced breakdown spectroscopy (LIBS), 3D needle assembly, SU-8 coatings and micromilling/ microdrilling techniques. The 3D MEAs demonstrate impedance characteristics similar to commercial MEAs. Additionally, all material combinations showed outstanding transparency and biocompatibility for applicability in 3D neuronal and cardiac studies."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Expanding the Capabilities of 3d Microelectrodes Arrays with A Multi-Material Palette and A 6-Well Flex Circuit System"]}]}],"canonical_facts":{"dc:contributor":["Rajaraman, Swaminathan"],"dc:creator":["Cepeda Torres, Omar S."],"dc:date.created":["2024-01-01T08:00:00Z","Summer","2025-08-15T07:00:00Z"],"dc:description":["Master of Science (M.S.)","Nanoscience and Technology Center","College of Graduate Studies","Nanotechnology"],"dc:description.abstract":["In this thesis we identify device (3D Microelectrode Arrays – 3D MEAs)/system (commercial electronics interface) issues preventing the scaling up of the world’s first in vitro model of afferent synaptic signaling in the spinal cord and develop a potential solution involving spin cast insulation and micromilled/microdrilled/microsoldered/flex circuit integrated 6-well interface board with connectors for analyzing up to six 3D MEAs simultaneously at one time. These novel advances can scale experimentation in the development of new treatments, pharmacological responses, and other electrophysiological discoveries for neurological disorders. In addition, we report on a multi-material palette towards the microfabrication of the aforementioned 3D Microelectrodes Arrays for integration with a variety of 3D electrogenic Microphysiological Systems (MPS) beyond the afferent synaptic model. The goal of this part of the thesis was to fabricate 3D MEAs with six microelectrodes by utilizing materials such as polycarbonate (PC), polymethyl methacrylate (PMMA), and polysulfone (PS). We created a reliable microfabrication process by combining laser micromachining, laser-induced breakdown spectroscopy (LIBS), 3D needle assembly, SU-8 coatings and micromilling/ microdrilling techniques. The 3D MEAs demonstrate impedance characteristics similar to commercial MEAs. Additionally, all material combinations showed outstanding transparency and biocompatibility for applicability in 3D neuronal and cardiac studies."],"dc:format":["application/pdf"],"dc:identifier":["DP0028487"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2023/282"],"dc:language":["English"],"dc:relation":["Orlando (Main) Campus"],"dc:subject":["Hybrid-Microfabrication 3D-Microelectrode-Arrays 3D-Electrogenic-Microphysiological-Systems 6-Well-Interface Flex-Circuit-Board Biocompatibility"],"dc:title":["Expanding the Capabilities of 3d Microelectrodes Arrays with A Multi-Material Palette and A 6-Well Flex Circuit System"],"dc:type":["Masters Thesis (Campus-only Access)"]},"updated_at":"2026-11-19T09:39:51Z"}