{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2024-1199"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2024-1199","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"MEMS-based Airflow Sensor for Apnea Detection Using Time-of-Flight Technique","abstract":"Sleep is essential for overall human health, influencing cognitive, emotional, and physical well-being. Respiratory-related sleep disorders, particularly obstructive sleep apnea (OSA), require early detection and effective treatment to prevent serious health complications. This dissertation explores innovative advancements in respiratory monitoring sensor development techniques, aiming to improve the diagnosis and management of sleep disorders. The sensor in this work incorporates a pair of Thin-film Piezoelectric on Substrate (TPoS) MEMS resonators operating at ~25 MHz, embedded in two oscillator circuits where frequency variations reflect changes in temperature and humidity caused by respiratory airflow. By precisely measuring airflow travel time between the resonators, the sensor calculates real-time flow rates and velocities with high sensitivity to subtle breathing pattern changes. A laminar airflow channel is carefully designed to minimize turbulence, ensuring more accurate Time-of-Flight-based airflow measurements. The system has undergone extensive experimental validation, including tests with a controlled respiration simulator that replicates human breathing patterns. Results show high precision and linearity, with the sensor accurately measuring flow rates between 0 and 10 L/min and velocities from 0 to 2 m/s, achieving an accuracy of 97.85%. Additionally, the system demonstrates excellent stability, featuring low phase noise, strong frequency response, and a high signal-to-noise ratio (SNR). The use of MEMS-based oscillators further enhances system robustness, while its low power consumption makes it ideal for continuous, real-time monitoring in both clinical and home settings.","abstract_html":"Sleep is essential for overall human health, influencing cognitive, emotional, and physical well-being. Respiratory-related sleep disorders, particularly obstructive sleep apnea (OSA), require early detection and effective treatment to prevent serious health complications. This dissertation explores innovative advancements in respiratory monitoring sensor development techniques, aiming to improve the diagnosis and management of sleep disorders. The sensor in this work incorporates a pair of Thin-film Piezoelectric on Substrate (TPoS) MEMS resonators operating at ~25 MHz, embedded in two oscillator circuits where frequency variations reflect changes in temperature and humidity caused by respiratory airflow. By precisely measuring airflow travel time between the resonators, the sensor calculates real-time flow rates and velocities with high sensitivity to subtle breathing pattern changes. A laminar airflow channel is carefully designed to minimize turbulence, ensuring more accurate Time-of-Flight-based airflow measurements. The system has undergone extensive experimental validation, including tests with a controlled respiration simulator that replicates human breathing patterns. Results show high precision and linearity, with the sensor accurately measuring flow rates between 0 and 10 L/min and velocities from 0 to 2 m/s, achieving an accuracy of 97.85%. Additionally, the system demonstrates excellent stability, featuring low phase noise, strong frequency response, and a high signal-to-noise ratio (SNR). The use of MEMS-based oscillators further enhances system robustness, while its low power consumption makes it ideal for continuous, real-time monitoring in both clinical and home settings.","abstract_has_math":false,"creators":["Akhkandi, Parvin"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Reza Abdolvand"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:40:40Z","subjects":["Airflow sensor","Obstructive Sleep Apnea (OSA)","Respiration monitoring","Time-of-Flight (ToF)","TPoS-MEMS Resonator","Laminar Flow","Air flow--Measurement; Sleep disorders--Research; Respiratory gas monitoring; Medical electronics--Technological innovations; Biosensors--Research"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0029256"],"render_values":[{"text":"DP0029256","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2024/90","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2024/90","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2024-1199","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Reza Abdolvand"]},{"key":"dc:creator","label":"Author","values":["Akhkandi, Parvin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z","Spring"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:relation","label":"Dc Relation","values":["Orlando (Main) Campus"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation/Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Airflow sensor","Obstructive Sleep Apnea (OSA)","Respiration monitoring","Time-of-Flight (ToF)","TPoS-MEMS Resonator","Laminar Flow","Air flow--Measurement; Sleep disorders--Research; Respiratory gas monitoring; Medical electronics--Technological innovations; Biosensors--Research"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0029256"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2024/90"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Electrical and Computer Engineering","College of Engineering and Computer Science"]},{"key":"dc:description.abstract","label":"Abstract","values":["Sleep is essential for overall human health, influencing cognitive, emotional, and physical well-being. Respiratory-related sleep disorders, particularly obstructive sleep apnea (OSA), require early detection and effective treatment to prevent serious health complications. This dissertation explores innovative advancements in respiratory monitoring sensor development techniques, aiming to improve the diagnosis and management of sleep disorders. The sensor in this work incorporates a pair of Thin-film Piezoelectric on Substrate (TPoS) MEMS resonators operating at ~25 MHz, embedded in two oscillator circuits where frequency variations reflect changes in temperature and humidity caused by respiratory airflow. By precisely measuring airflow travel time between the resonators, the sensor calculates real-time flow rates and velocities with high sensitivity to subtle breathing pattern changes. A laminar airflow channel is carefully designed to minimize turbulence, ensuring more accurate Time-of-Flight-based airflow measurements. The system has undergone extensive experimental validation, including tests with a controlled respiration simulator that replicates human breathing patterns. Results show high precision and linearity, with the sensor accurately measuring flow rates between 0 and 10 L/min and velocities from 0 to 2 m/s, achieving an accuracy of 97.85%. Additionally, the system demonstrates excellent stability, featuring low phase noise, strong frequency response, and a high signal-to-noise ratio (SNR). The use of MEMS-based oscillators further enhances system robustness, while its low power consumption makes it ideal for continuous, real-time monitoring in both clinical and home settings."]},{"key":"dc:title","label":"Title","values":["MEMS-based Airflow Sensor for Apnea Detection Using Time-of-Flight Technique"]}]}],"canonical_facts":{"dc:contributor":["Reza Abdolvand"],"dc:creator":["Akhkandi, Parvin"],"dc:date.created":["2025-01-01T08:00:00Z","Spring"],"dc:description":["Doctor of Philosophy (Ph.D.)","Electrical and Computer Engineering","College of Engineering and Computer Science"],"dc:description.abstract":["Sleep is essential for overall human health, influencing cognitive, emotional, and physical well-being. Respiratory-related sleep disorders, particularly obstructive sleep apnea (OSA), require early detection and effective treatment to prevent serious health complications. This dissertation explores innovative advancements in respiratory monitoring sensor development techniques, aiming to improve the diagnosis and management of sleep disorders. The sensor in this work incorporates a pair of Thin-film Piezoelectric on Substrate (TPoS) MEMS resonators operating at ~25 MHz, embedded in two oscillator circuits where frequency variations reflect changes in temperature and humidity caused by respiratory airflow. By precisely measuring airflow travel time between the resonators, the sensor calculates real-time flow rates and velocities with high sensitivity to subtle breathing pattern changes. A laminar airflow channel is carefully designed to minimize turbulence, ensuring more accurate Time-of-Flight-based airflow measurements. The system has undergone extensive experimental validation, including tests with a controlled respiration simulator that replicates human breathing patterns. Results show high precision and linearity, with the sensor accurately measuring flow rates between 0 and 10 L/min and velocities from 0 to 2 m/s, achieving an accuracy of 97.85%. Additionally, the system demonstrates excellent stability, featuring low phase noise, strong frequency response, and a high signal-to-noise ratio (SNR). The use of MEMS-based oscillators further enhances system robustness, while its low power consumption makes it ideal for continuous, real-time monitoring in both clinical and home settings."],"dc:identifier":["DP0029256"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2024/90"],"dc:publisher":["University of Central Florida"],"dc:relation":["Orlando (Main) Campus"],"dc:subject":["Airflow sensor","Obstructive Sleep Apnea (OSA)","Respiration monitoring","Time-of-Flight (ToF)","TPoS-MEMS Resonator","Laminar Flow","Air flow--Measurement; Sleep disorders--Research; Respiratory gas monitoring; Medical electronics--Technological innovations; Biosensors--Research"],"dc:title":["MEMS-based Airflow Sensor for Apnea Detection Using Time-of-Flight Technique"],"dc:type":["Dissertation/Thesis"]},"updated_at":"2026-11-19T09:40:40Z"}