{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:etd2024-1531"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:etd2024-1531","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"High-Efficiency Dual Active Bridge Converter With Stacked Secondary Phase For Next-Generation AI Data Center Power Delivery","abstract":"The rapid electrification of hyperscale AI data centers is accelerating a shift from legacy 48 V distribution ladders to ±400 V high-voltage DC backbones, concentrating residual loss and dynamic stress on a single isolated bidirectional interface. This work presents a high-density Dual Active Bridge with Stacked Secondary Phasing (DAB-SSP) architecture as a scalable GaN-based solution for 48 V–800 V rack-level power conversion. By stacking 400 V secondaries, the topology leverages 650 V GaN devices while satisfying 800 V system requirements, reducing clearance and creepage distances, minimizing magnetic path lengths, and embedding leakage inductance necessary for wide-range zero-voltage switching. A rigorous time-domain modeling framework is developed for single and dual phase-shift operation, yielding closed-form solutions for power transfer, RMS current stress, and soft-switching boundaries. An optimal control formulation based on Pontryagin’s Minimum Principle minimizes conduction loss while maintaining power transfer, providing a globally optimal phase schedule and revealing fundamental efficiency trade-offs. These analytical results are paired with a physics-based design methodology that links modulation strategy, magnetic geometry, and device characteristics. The models are validated in GaN-based hardware demonstrating peak efficiencies exceeding 98 % with wide-range ZVS and stable transient response. Experimental thermal and calorimetric data confirm close agreement with the theoretical loss framework. The resulting converter provides a compact, efficient, and bidirectional interface for AI data center backbones, enabling peak shaving, renewable energy absorption, and fast ride-through without intermediate stages. This work establishes the DAB-SSP as a building block for future high-voltage, high-density power delivery systems","abstract_html":"The rapid electrification of hyperscale AI data centers is accelerating a shift from legacy 48 V distribution ladders to ±400 V high-voltage DC backbones, concentrating residual loss and dynamic stress on a single isolated bidirectional interface. This work presents a high-density Dual Active Bridge with Stacked Secondary Phasing (DAB-SSP) architecture as a scalable GaN-based solution for 48 V–800 V rack-level power conversion. By stacking 400 V secondaries, the topology leverages 650 V GaN devices while satisfying 800 V system requirements, reducing clearance and creepage distances, minimizing magnetic path lengths, and embedding leakage inductance necessary for wide-range zero-voltage switching. A rigorous time-domain modeling framework is developed for single and dual phase-shift operation, yielding closed-form solutions for power transfer, RMS current stress, and soft-switching boundaries. An optimal control formulation based on Pontryagin’s Minimum Principle minimizes conduction loss while maintaining power transfer, providing a globally optimal phase schedule and revealing fundamental efficiency trade-offs. These analytical results are paired with a physics-based design methodology that links modulation strategy, magnetic geometry, and device characteristics. The models are validated in GaN-based hardware demonstrating peak efficiencies exceeding 98 % with wide-range ZVS and stable transient response. Experimental thermal and calorimetric data confirm close agreement with the theoretical loss framework. The resulting converter provides a compact, efficient, and bidirectional interface for AI data center backbones, enabling peak shaving, renewable energy absorption, and fast ride-through without intermediate stages. This work establishes the DAB-SSP as a building block for future high-voltage, high-density power delivery systems","abstract_has_math":false,"creators":["Ashok Pise, Anirudh"],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Issa Batarseh"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:40:50Z","subjects":["Dual Active Bridge (DAB)","Stacked Secondary Phasing (SSP)","High-Voltage","DC Power Delivery","Gallium Nitride (GaN) Converters","Optimal Phase-Shift Control","AI Data Center Power Systems","DC-to-DC converters--Design and construction; Power electronics--Design and construction; DC-to-DC converters; Power semiconductors--Design and construction; Switching power supplies--Design and construction"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0029793"],"render_values":[{"text":"DP0029793","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/etd2024/419","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/etd2024/419","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Aetd2024-1531","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Issa Batarseh"]},{"key":"dc:creator","label":"Author","values":["Ashok Pise, Anirudh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z","Fall"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:relation","label":"Dc Relation","values":["Orlando (Main) Campus"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dual Active Bridge (DAB)","Stacked Secondary Phasing (SSP)","High-Voltage","DC Power Delivery","Gallium Nitride (GaN) Converters","Optimal Phase-Shift Control","AI Data Center Power Systems","DC-to-DC converters--Design and construction; Power electronics--Design and construction; DC-to-DC converters; Power semiconductors--Design and construction; Switching power supplies--Design and construction"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0029793"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/etd2024/419"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Doctor of Philosophy (Ph.D.)","Department of Electrical and Computer Engineering","College of Engineering and Computer Science"]},{"key":"dc:description.abstract","label":"Abstract","values":["The rapid electrification of hyperscale AI data centers is accelerating a shift from legacy 48 V distribution ladders to ±400 V high-voltage DC backbones, concentrating residual loss and dynamic stress on a single isolated bidirectional interface. This work presents a high-density Dual Active Bridge with Stacked Secondary Phasing (DAB-SSP) architecture as a scalable GaN-based solution for 48 V–800 V rack-level power conversion. By stacking 400 V secondaries, the topology leverages 650 V GaN devices while satisfying 800 V system requirements, reducing clearance and creepage distances, minimizing magnetic path lengths, and embedding leakage inductance necessary for wide-range zero-voltage switching. A rigorous time-domain modeling framework is developed for single and dual phase-shift operation, yielding closed-form solutions for power transfer, RMS current stress, and soft-switching boundaries. An optimal control formulation based on Pontryagin’s Minimum Principle minimizes conduction loss while maintaining power transfer, providing a globally optimal phase schedule and revealing fundamental efficiency trade-offs. These analytical results are paired with a physics-based design methodology that links modulation strategy, magnetic geometry, and device characteristics. The models are validated in GaN-based hardware demonstrating peak efficiencies exceeding 98 % with wide-range ZVS and stable transient response. Experimental thermal and calorimetric data confirm close agreement with the theoretical loss framework. The resulting converter provides a compact, efficient, and bidirectional interface for AI data center backbones, enabling peak shaving, renewable energy absorption, and fast ride-through without intermediate stages. This work establishes the DAB-SSP as a building block for future high-voltage, high-density power delivery systems"]},{"key":"dc:format","label":"Dc Format","values":["PDF"]},{"key":"dc:title","label":"Title","values":["High-Efficiency Dual Active Bridge Converter With Stacked Secondary Phase For Next-Generation AI Data Center Power Delivery"]}]}],"canonical_facts":{"dc:contributor":["Issa Batarseh"],"dc:creator":["Ashok Pise, Anirudh"],"dc:date.created":["2025-01-01T08:00:00Z","Fall"],"dc:description":["Doctor of Philosophy (Ph.D.)","Department of Electrical and Computer Engineering","College of Engineering and Computer Science"],"dc:description.abstract":["The rapid electrification of hyperscale AI data centers is accelerating a shift from legacy 48 V distribution ladders to ±400 V high-voltage DC backbones, concentrating residual loss and dynamic stress on a single isolated bidirectional interface. This work presents a high-density Dual Active Bridge with Stacked Secondary Phasing (DAB-SSP) architecture as a scalable GaN-based solution for 48 V–800 V rack-level power conversion. By stacking 400 V secondaries, the topology leverages 650 V GaN devices while satisfying 800 V system requirements, reducing clearance and creepage distances, minimizing magnetic path lengths, and embedding leakage inductance necessary for wide-range zero-voltage switching. A rigorous time-domain modeling framework is developed for single and dual phase-shift operation, yielding closed-form solutions for power transfer, RMS current stress, and soft-switching boundaries. An optimal control formulation based on Pontryagin’s Minimum Principle minimizes conduction loss while maintaining power transfer, providing a globally optimal phase schedule and revealing fundamental efficiency trade-offs. These analytical results are paired with a physics-based design methodology that links modulation strategy, magnetic geometry, and device characteristics. The models are validated in GaN-based hardware demonstrating peak efficiencies exceeding 98 % with wide-range ZVS and stable transient response. Experimental thermal and calorimetric data confirm close agreement with the theoretical loss framework. The resulting converter provides a compact, efficient, and bidirectional interface for AI data center backbones, enabling peak shaving, renewable energy absorption, and fast ride-through without intermediate stages. This work establishes the DAB-SSP as a building block for future high-voltage, high-density power delivery systems"],"dc:format":["PDF"],"dc:identifier":["DP0029793"],"dc:identifier.uri":["https://stars.library.ucf.edu/etd2024/419"],"dc:publisher":["University of Central Florida"],"dc:relation":["Orlando (Main) Campus"],"dc:subject":["Dual Active Bridge (DAB)","Stacked Secondary Phasing (SSP)","High-Voltage","DC Power Delivery","Gallium Nitride (GaN) Converters","Optimal Phase-Shift Control","AI Data Center Power Systems","DC-to-DC converters--Design and construction; Power electronics--Design and construction; DC-to-DC converters; Power semiconductors--Design and construction; Switching power supplies--Design and construction"],"dc:title":["High-Efficiency Dual Active Bridge Converter With Stacked Secondary Phase For Next-Generation AI Data Center Power Delivery"],"dc:type":["Thesis"]},"updated_at":"2026-11-19T09:40:50Z"}