{"id":{"repo_id":"ucf","oai_identifier":"oai:stars.library.ucf.edu:rtd-5801"},"canonical_url":"https://search.ndltd.org/etd/ucf/oai:stars.library.ucf.edu:rtd-5801","repository":{"repo_id":"ucf","name":"Central Florida","base_url":"https://stars.library.ucf.edu/do/oai/"},"display":{"title":"Fiber Optic Temperature Sensors for a Large Electric Power Generator","abstract":"Fiber optic temperature sensors are excellent candidates for monitoring the temperature along the stator windings of a large electric power generator. Unlike thermocouple thermometers, they are immune to the effects of strong magnetic fields which are present in all power generators. Several different point and line sensors have been evaluated in their ability to resolve temperature and temperature distribution (respectively), as well as their compatibility with the generator environment. The sensor must function inside the generator for long periods of time (up to 25 years) without benefit of recalibration. This constraint has required us to devise methods by which the sensor may remain permanently calibrated. In almost all cases, it is necessary to measure a natural characteristic of a device which is temperature sensitive in order to achieve permanent calibration. This will enable the device to function despite the varying characteristics of the source and detector equipment.","abstract_html":"Fiber optic temperature sensors are excellent candidates for monitoring the temperature along the stator windings of a large electric power generator. Unlike thermocouple thermometers, they are immune to the effects of strong magnetic fields which are present in all power generators. Several different point and line sensors have been evaluated in their ability to resolve temperature and temperature distribution (respectively), as well as their compatibility with the generator environment. The sensor must function inside the generator for long periods of time (up to 25 years) without benefit of recalibration. This constraint has required us to devise methods by which the sensor may remain permanently calibrated. In almost all cases, it is necessary to measure a natural characteristic of a device which is temperature sensitive in order to achieve permanent calibration. This will enable the device to function despite the varying characteristics of the source and detector equipment.","abstract_has_math":false,"creators":["Lester, Daniel A."],"institution":"University of Central Florida","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Walters, Roy A.","<p><a href=\"https://www.wikidata.org/wiki/Q60030805\">Roy A. Walters (Q60030805)</a></p> <p><a href=\"http://viaf.org/viaf/155956728\">University of Central Florida. College of Engineering</a> [VIAF]</p> <p><a href=\"http://id.loc.gov/authorities/names/n82027354.html\">University of Central Florida. College of Engineering</a> [LC]</p>"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T06:10:44Z","subjects":["Detectors","Electric generators","Fiber optics","Stator winding temperature monitoring","Distributed fiber optic sensing","Magnetic-field immune sensors","Self-referencing calibration","25-year calibration-free operation","Engineering","Optical fiber detectors--Industrial applications; Temperature measurements--Industrial applications; Optical fibers--Reliability; Optical fiber detectors--Design and construction; Electric generators--Reliability"],"languages":["English"],"rights":["Public Domain"],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0017526"],"render_values":[{"text":"DP0017526","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://stars.library.ucf.edu/rtd/4802","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://stars.library.ucf.edu/rtd/4802","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucf%3Aoai%3Astars.library.ucf.edu%3Artd-5801","prefix":"oai_dc"},"source_record":{"url":"https://stars.library.ucf.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Astars.library.ucf.edu%3Artd-5801","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Walters, Roy A.","<p><a href=\"https://www.wikidata.org/wiki/Q60030805\">Roy A. Walters (Q60030805)</a></p> <p><a href=\"http://viaf.org/viaf/155956728\">University of Central Florida. College of Engineering</a> [VIAF]</p> <p><a href=\"http://id.loc.gov/authorities/names/n82027354.html\">University of Central Florida. College of Engineering</a> [LC]</p>"]},{"key":"dc:creator","label":"Author","values":["Lester, Daniel A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["1985-01-01T08:00:00Z","Fall"]},{"key":"dc:publisher","label":"Institution","values":["University of Central Florida"]},{"key":"dc:type","label":"Dc Type","values":["Masters Thesis (Open Access)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Detectors","Electric generators","Fiber optics","Stator winding temperature monitoring","Distributed fiber optic sensing","Magnetic-field immune sensors","Self-referencing calibration","25-year calibration-free operation","Engineering","Optical fiber detectors--Industrial applications; Temperature measurements--Industrial applications; Optical fibers--Reliability; Optical fiber detectors--Design and construction; Electric generators--Reliability"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights","label":"Dc Rights","values":["Public Domain"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["DP0017526"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://stars.library.ucf.edu/rtd/4802"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Master of Science (M.S.)","Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Fiber optic temperature sensors are excellent candidates for monitoring the temperature along the stator windings of a large electric power generator. Unlike thermocouple thermometers, they are immune to the effects of strong magnetic fields which are present in all power generators. Several different point and line sensors have been evaluated in their ability to resolve temperature and temperature distribution (respectively), as well as their compatibility with the generator environment. The sensor must function inside the generator for long periods of time (up to 25 years) without benefit of recalibration. This constraint has required us to devise methods by which the sensor may remain permanently calibrated. In almost all cases, it is necessary to measure a natural characteristic of a device which is temperature sensitive in order to achieve permanent calibration. This will enable the device to function despite the varying characteristics of the source and detector equipment."]},{"key":"dc:format","label":"Dc Format","values":["PDF"]},{"key":"dc:title","label":"Title","values":["Fiber Optic Temperature Sensors for a Large Electric Power Generator"]}]}],"canonical_facts":{"dc:contributor":["Walters, Roy A.","<p><a href=\"https://www.wikidata.org/wiki/Q60030805\">Roy A. Walters (Q60030805)</a></p> <p><a href=\"http://viaf.org/viaf/155956728\">University of Central Florida. College of Engineering</a> [VIAF]</p> <p><a href=\"http://id.loc.gov/authorities/names/n82027354.html\">University of Central Florida. College of Engineering</a> [LC]</p>"],"dc:creator":["Lester, Daniel A."],"dc:date.created":["1985-01-01T08:00:00Z","Fall"],"dc:description":["Master of Science (M.S.)","Engineering","<p>If this is your thesis or dissertation, and want to learn how to access it or for more information about readership statistics, contact us at <a href=\"mailto:stars@ucf.edu\">STARS@ucf.edu</a></p>","College of Engineering"],"dc:description.abstract":["Fiber optic temperature sensors are excellent candidates for monitoring the temperature along the stator windings of a large electric power generator. Unlike thermocouple thermometers, they are immune to the effects of strong magnetic fields which are present in all power generators. Several different point and line sensors have been evaluated in their ability to resolve temperature and temperature distribution (respectively), as well as their compatibility with the generator environment. The sensor must function inside the generator for long periods of time (up to 25 years) without benefit of recalibration. This constraint has required us to devise methods by which the sensor may remain permanently calibrated. In almost all cases, it is necessary to measure a natural characteristic of a device which is temperature sensitive in order to achieve permanent calibration. This will enable the device to function despite the varying characteristics of the source and detector equipment."],"dc:format":["PDF"],"dc:identifier":["DP0017526"],"dc:identifier.uri":["https://stars.library.ucf.edu/rtd/4802"],"dc:language":["English"],"dc:publisher":["University of Central Florida"],"dc:rights":["Public Domain"],"dc:subject":["Detectors","Electric generators","Fiber optics","Stator winding temperature monitoring","Distributed fiber optic sensing","Magnetic-field immune sensors","Self-referencing calibration","25-year calibration-free operation","Engineering","Optical fiber detectors--Industrial applications; Temperature measurements--Industrial applications; Optical fibers--Reliability; Optical fiber detectors--Design and construction; Electric generators--Reliability"],"dc:title":["Fiber Optic Temperature Sensors for a Large Electric Power Generator"],"dc:type":["Masters Thesis (Open Access)"]},"updated_at":"2026-11-27T06:10:44Z"}