{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10065508"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10065508","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Optimising MRI magnetic susceptibility mapping for the study of brain arteriovenous malformations","abstract":"Magnetic resonance imaging (MRI) magnetic susceptibility mapping (SM) enables the calculation of the magnetic susceptibility of biological tissues based on the signal phase of a gradient-recalled echo (GRE) MRI acquisition. Because deoxygenated haemoglobin is paramagnetic, SM can be used to calculate the χ of venous blood which is proportional to venous oxygen saturation (SvO2). In this thesis, I investigated the feasibility of SM for the study of brain arteriovenous malformations (AVMs). AVMs are congenital vascular anomalies characterised by arteriovenous shunting through a network of coiled and tortuous vessels. Because of this anatomy, the venous drainage of an AVM contains high-pressure mixed arterial and venous blood. I investigated whether SM could detect any resulting increased oxygenation in the draining veins. Using numerical simulations and healthy volunteer data, I focussed on optimising the acquisition and processing of GRE phase data to achieve the best possible accuracy and precision for venous SM. I showed that acquiring multi-echo versus single-echo GRE data led to more accurate and precise susceptibility, and that combining the signal from multiple echoes before applying Laplacian-based phase unwrapping or background field removal increased the susceptibility’s accuracy. Based on healthy volunteer and patient data (before and after gamma knife radiosurgery (GKR)) I investigated the feasibility of SM of brain AVMs and the information provided by venous susceptibility on AVM pathophysiology. I showed that an AVM was detectable on a susceptibility map and that the AVM draining pattern had a significantly higher SvO2 compared to healthy veins. Flowing spins in blood cause an additional susceptibility-independent component in the GRE signal phase. Because clinical multi-echo GRE protocols, including the one developed here to study brain AVMs, do not compensate for flow-induced dephasing, I investigated the effect of flow compensation on venous susceptibility and SvO2 measurements and found only a minimal effect.","abstract_html":"Magnetic resonance imaging (MRI) magnetic susceptibility mapping (SM) enables the calculation of the magnetic susceptibility of biological tissues based on the signal phase of a gradient-recalled echo (GRE) MRI acquisition. Because deoxygenated haemoglobin is paramagnetic, SM can be used to calculate the χ of venous blood which is proportional to venous oxygen saturation (SvO2). In this thesis, I investigated the feasibility of SM for the study of brain arteriovenous malformations (AVMs). AVMs are congenital vascular anomalies characterised by arteriovenous shunting through a network of coiled and tortuous vessels. Because of this anatomy, the venous drainage of an AVM contains high-pressure mixed arterial and venous blood. I investigated whether SM could detect any resulting increased oxygenation in the draining veins. Using numerical simulations and healthy volunteer data, I focussed on optimising the acquisition and processing of GRE phase data to achieve the best possible accuracy and precision for venous SM. I showed that acquiring multi-echo versus single-echo GRE data led to more accurate and precise susceptibility, and that combining the signal from multiple echoes before applying Laplacian-based phase unwrapping or background field removal increased the susceptibility’s accuracy. Based on healthy volunteer and patient data (before and after gamma knife radiosurgery (GKR)) I investigated the feasibility of SM of brain AVMs and the information provided by venous susceptibility on AVM pathophysiology. I showed that an AVM was detectable on a susceptibility map and that the AVM draining pattern had a significantly higher SvO2 compared to healthy veins. Flowing spins in blood cause an additional susceptibility-independent component in the GRE signal phase. Because clinical multi-echo GRE protocols, including the one developed here to study brain AVMs, do not compensate for flow-induced dephasing, I investigated the effect of flow compensation on venous susceptibility and SvO2 measurements and found only a minimal effect.","abstract_has_math":false,"creators":["Biondetti, Emma"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Shmueli, K","Thomas, D"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-01","date_published":"2019-01","updated_at":"2026-11-26T05:30:31Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10065508/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10065508/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10065508","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10065508","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shmueli, K","Thomas, D"]},{"key":"dc:creator","label":"Author","values":["Biondetti, Emma"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-01-28"]},{"key":"dc:date.issued","label":"Date","values":["2019-01"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10065508/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance imaging (MRI) magnetic susceptibility mapping (SM) enables the calculation of the magnetic susceptibility of biological tissues based on the signal phase of a gradient-recalled echo (GRE) MRI acquisition. Because deoxygenated haemoglobin is paramagnetic, SM can be used to calculate the χ of venous blood which is proportional to venous oxygen saturation (SvO2). In this thesis, I investigated the feasibility of SM for the study of brain arteriovenous malformations (AVMs). AVMs are congenital vascular anomalies characterised by arteriovenous shunting through a network of coiled and tortuous vessels. Because of this anatomy, the venous drainage of an AVM contains high-pressure mixed arterial and venous blood. I investigated whether SM could detect any resulting increased oxygenation in the draining veins. Using numerical simulations and healthy volunteer data, I focussed on optimising the acquisition and processing of GRE phase data to achieve the best possible accuracy and precision for venous SM. I showed that acquiring multi-echo versus single-echo GRE data led to more accurate and precise susceptibility, and that combining the signal from multiple echoes before applying Laplacian-based phase unwrapping or background field removal increased the susceptibility’s accuracy. Based on healthy volunteer and patient data (before and after gamma knife radiosurgery (GKR)) I investigated the feasibility of SM of brain AVMs and the information provided by venous susceptibility on AVM pathophysiology. I showed that an AVM was detectable on a susceptibility map and that the AVM draining pattern had a significantly higher SvO2 compared to healthy veins. Flowing spins in blood cause an additional susceptibility-independent component in the GRE signal phase. Because clinical multi-echo GRE protocols, including the one developed here to study brain AVMs, do not compensate for flow-induced dephasing, I investigated the effect of flow compensation on venous susceptibility and SvO2 measurements and found only a minimal effect."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Optimising MRI magnetic susceptibility mapping for the study of brain arteriovenous malformations"]}]}],"canonical_facts":{"dc:contributor":["Shmueli, K","Thomas, D"],"dc:creator":["Biondetti, Emma"],"dc:date":["2019-01-28"],"dc:date.issued":["2019-01"],"dc:description.abstract":["Magnetic resonance imaging (MRI) magnetic susceptibility mapping (SM) enables the calculation of the magnetic susceptibility of biological tissues based on the signal phase of a gradient-recalled echo (GRE) MRI acquisition. Because deoxygenated haemoglobin is paramagnetic, SM can be used to calculate the χ of venous blood which is proportional to venous oxygen saturation (SvO2). In this thesis, I investigated the feasibility of SM for the study of brain arteriovenous malformations (AVMs). AVMs are congenital vascular anomalies characterised by arteriovenous shunting through a network of coiled and tortuous vessels. Because of this anatomy, the venous drainage of an AVM contains high-pressure mixed arterial and venous blood. I investigated whether SM could detect any resulting increased oxygenation in the draining veins. Using numerical simulations and healthy volunteer data, I focussed on optimising the acquisition and processing of GRE phase data to achieve the best possible accuracy and precision for venous SM. I showed that acquiring multi-echo versus single-echo GRE data led to more accurate and precise susceptibility, and that combining the signal from multiple echoes before applying Laplacian-based phase unwrapping or background field removal increased the susceptibility’s accuracy. Based on healthy volunteer and patient data (before and after gamma knife radiosurgery (GKR)) I investigated the feasibility of SM of brain AVMs and the information provided by venous susceptibility on AVM pathophysiology. I showed that an AVM was detectable on a susceptibility map and that the AVM draining pattern had a significantly higher SvO2 compared to healthy veins. Flowing spins in blood cause an additional susceptibility-independent component in the GRE signal phase. Because clinical multi-echo GRE protocols, including the one developed here to study brain AVMs, do not compensate for flow-induced dephasing, I investigated the effect of flow compensation on venous susceptibility and SvO2 measurements and found only a minimal effect."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10065508/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Optimising MRI magnetic susceptibility mapping for the study of brain arteriovenous malformations"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T05:30:31Z"}