{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10068912"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10068912","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Robust and Fast Quantitative MRI for Clinical Deployment","abstract":"Within this thesis, my work carried out in order to prepare an existing quantitative imaging method, multi-parameter mapping, for clinical use, is summarized. My tasks were to improve the motion-robustness of the acquisitions used in this protocol, and to reduce the scan time of the protocol to a clinically viable level. In order to reduce acquisition times, I investigated the use of higher parallel imaging acceleration factors, compared to those used in the protocol to date. I found that increasing the acceleration factor from 2 to 2-by-2 is a viable approach to decrease scan time, as is elliptical k-space coverage. In order to improve the robustness versus inter-scan motion, I investigated the effect of inter-scan motion on the quantitative maps derived from the protocol. I found that, while rigid-body motion correction is not sufficient in cases where a map is calculated from more than one scan, as the changes in the receive field are unaccounted for. I introduced a correction method, based on measuring the receive field for each structural scan, and showed that it improves image quality in the presence of inter-scan motion. Motion robustness was also improved by selecting a relatively motioninsensitive acquisition trajectory, from a set of clinically available trajectories. To further address the issue of intra-scan motion, I developed a novel navigator technique, based on acquiring data concurrent with gradient spoiling. Crucially, the acquisition of this navigator did not require additional scan time. I found that this navigator is sufficiently sensitive to motion, such that outlier rejection can be used to identify motion-corrupted data points. I implemented a data re-acquisition approach, based on the outlier rejection, and showed that image quality can be improved by this method.","abstract_html":"Within this thesis, my work carried out in order to prepare an existing quantitative imaging method, multi-parameter mapping, for clinical use, is summarized. My tasks were to improve the motion-robustness of the acquisitions used in this protocol, and to reduce the scan time of the protocol to a clinically viable level. In order to reduce acquisition times, I investigated the use of higher parallel imaging acceleration factors, compared to those used in the protocol to date. I found that increasing the acceleration factor from 2 to 2-by-2 is a viable approach to decrease scan time, as is elliptical k-space coverage. In order to improve the robustness versus inter-scan motion, I investigated the effect of inter-scan motion on the quantitative maps derived from the protocol. I found that, while rigid-body motion correction is not sufficient in cases where a map is calculated from more than one scan, as the changes in the receive field are unaccounted for. I introduced a correction method, based on measuring the receive field for each structural scan, and showed that it improves image quality in the presence of inter-scan motion. Motion robustness was also improved by selecting a relatively motioninsensitive acquisition trajectory, from a set of clinically available trajectories. To further address the issue of intra-scan motion, I developed a novel navigator technique, based on acquiring data concurrent with gradient spoiling. Crucially, the acquisition of this navigator did not require additional scan time. I found that this navigator is sufficiently sensitive to motion, such that outlier rejection can be used to identify motion-corrupted data points. I implemented a data re-acquisition approach, based on the outlier rejection, and showed that image quality can be improved by this method.","abstract_has_math":false,"creators":["Papp, Daniel"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-02","date_published":"2019-02","updated_at":"2026-11-26T05:31:06Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10068912/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10068912/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10068912","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10068912","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Papp, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-02-28"]},{"key":"dc:date.issued","label":"Date","values":["2019-02"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Neurology"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10068912/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Within this thesis, my work carried out in order to prepare an existing quantitative imaging method, multi-parameter mapping, for clinical use, is summarized. My tasks were to improve the motion-robustness of the acquisitions used in this protocol, and to reduce the scan time of the protocol to a clinically viable level. In order to reduce acquisition times, I investigated the use of higher parallel imaging acceleration factors, compared to those used in the protocol to date. I found that increasing the acceleration factor from 2 to 2-by-2 is a viable approach to decrease scan time, as is elliptical k-space coverage. In order to improve the robustness versus inter-scan motion, I investigated the effect of inter-scan motion on the quantitative maps derived from the protocol. I found that, while rigid-body motion correction is not sufficient in cases where a map is calculated from more than one scan, as the changes in the receive field are unaccounted for. I introduced a correction method, based on measuring the receive field for each structural scan, and showed that it improves image quality in the presence of inter-scan motion. Motion robustness was also improved by selecting a relatively motioninsensitive acquisition trajectory, from a set of clinically available trajectories. To further address the issue of intra-scan motion, I developed a novel navigator technique, based on acquiring data concurrent with gradient spoiling. Crucially, the acquisition of this navigator did not require additional scan time. I found that this navigator is sufficiently sensitive to motion, such that outlier rejection can be used to identify motion-corrupted data points. I implemented a data re-acquisition approach, based on the outlier rejection, and showed that image quality can be improved by this method."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Robust and Fast Quantitative MRI for Clinical Deployment"]}]}],"canonical_facts":{"dc:creator":["Papp, Daniel"],"dc:date":["2019-02-28"],"dc:date.issued":["2019-02"],"dc:description.abstract":["Within this thesis, my work carried out in order to prepare an existing quantitative imaging method, multi-parameter mapping, for clinical use, is summarized. My tasks were to improve the motion-robustness of the acquisitions used in this protocol, and to reduce the scan time of the protocol to a clinically viable level. In order to reduce acquisition times, I investigated the use of higher parallel imaging acceleration factors, compared to those used in the protocol to date. I found that increasing the acceleration factor from 2 to 2-by-2 is a viable approach to decrease scan time, as is elliptical k-space coverage. In order to improve the robustness versus inter-scan motion, I investigated the effect of inter-scan motion on the quantitative maps derived from the protocol. I found that, while rigid-body motion correction is not sufficient in cases where a map is calculated from more than one scan, as the changes in the receive field are unaccounted for. I introduced a correction method, based on measuring the receive field for each structural scan, and showed that it improves image quality in the presence of inter-scan motion. Motion robustness was also improved by selecting a relatively motioninsensitive acquisition trajectory, from a set of clinically available trajectories. To further address the issue of intra-scan motion, I developed a novel navigator technique, based on acquiring data concurrent with gradient spoiling. Crucially, the acquisition of this navigator did not require additional scan time. I found that this navigator is sufficiently sensitive to motion, such that outlier rejection can be used to identify motion-corrupted data points. I implemented a data re-acquisition approach, based on the outlier rejection, and showed that image quality can be improved by this method."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10068912/"],"dc:language":["en","eng"],"dc:publisher.department":["Institute of Neurology"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Robust and Fast Quantitative MRI for Clinical Deployment"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T05:31:06Z"}