{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10069911"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10069911","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"The Effect of Different Implant-Abutment Connection Geometry and Abutment Alloy on Corrosion Product Release and Cell Response","abstract":"Problem: The observed positive effect of the platform-switching concept on peri- implant bone level is not well understood. Dental implants may be prone to tribocorrosion leading to the release of metal ions and particles which may disrupt bone homeostasis Objectives: The aim of this project was to compare the amount of corrosion products released from different implant-abutment couplings with different connection geometries under accelerated corrosion tests, and to evaluate different osteoblastic cell responses to the released products. Materials and methods: Part I: Titanium cylinders were connected to titanium alloy (Ti-6Al-4V) and cobalt– chrome alloy abutments forming either platform-switched or platform-matched groups. Samples were subjected to static immersion in 1% lactic acid for 1 week. Metal ions released were measured and microscopic analyses were performed pre- and post- immersion to assess corrosion at the interface. Part II: Osteoblasts were treated with culture media containing different concentrations of metal ions obtained from the results of part I. Osteoblasts treated with ion-free culture medium served as the controls. Osteoblastic viability, apoptosis and expression of genes related to bone resorption were analysed. Part III: The samples used in part I were incubated with osteoblasts. Viability, apoptosis and expression of the genes tested in part II were investigated. Part IV: Titanium implants were coupled with either titanium, gold, cobalt-chrome, or zirconia abutments forming either platform-switched or platform-matched groups. The specimens were subjected to cyclic loading under wet acidic environment. Metal ions released were measured and microscopic evaluations were performed pre- and post- immersion for tribocorrosion assessment and wear particle characterization. Results: Part I: The implant–abutment couplings underwent an active corrosion process resulting in metal ions released into the surrounding environment. The platform- matched groups demonstrated higher amount of metal ion release. Part II and Part III: Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of both the metal ions and the different implant-abutment couplings. The observed changes in some of the biological responses tested were more pronounced in groups representing the platform-matched implant-abutment couplings. Part IV: The implant–abutment couplings underwent an active tribocorrosion processes resulting in metal ions and wear particles released into the surrounding environment. The platform-matched groups demonstrated higher amount of metal ion release and more surface damage Conclusion: Platform-switching concept had a positive effect in reducing metal ion release and wear features from dental implants which in turn minimised the adverse osteoblastic biologic responses related to peri-implant bone loss, therefore highlighting the possible role of corrosion products in the mediation of crestal bone loss around dental implants","abstract_html":"Problem: The observed positive effect of the platform-switching concept on peri- implant bone level is not well understood. Dental implants may be prone to tribocorrosion leading to the release of metal ions and particles which may disrupt bone homeostasis Objectives: The aim of this project was to compare the amount of corrosion products released from different implant-abutment couplings with different connection geometries under accelerated corrosion tests, and to evaluate different osteoblastic cell responses to the released products. Materials and methods: Part I: Titanium cylinders were connected to titanium alloy (Ti-6Al-4V) and cobalt– chrome alloy abutments forming either platform-switched or platform-matched groups. Samples were subjected to static immersion in 1% lactic acid for 1 week. Metal ions released were measured and microscopic analyses were performed pre- and post- immersion to assess corrosion at the interface. Part II: Osteoblasts were treated with culture media containing different concentrations of metal ions obtained from the results of part I. Osteoblasts treated with ion-free culture medium served as the controls. Osteoblastic viability, apoptosis and expression of genes related to bone resorption were analysed. Part III: The samples used in part I were incubated with osteoblasts. Viability, apoptosis and expression of the genes tested in part II were investigated. Part IV: Titanium implants were coupled with either titanium, gold, cobalt-chrome, or zirconia abutments forming either platform-switched or platform-matched groups. The specimens were subjected to cyclic loading under wet acidic environment. Metal ions released were measured and microscopic evaluations were performed pre- and post- immersion for tribocorrosion assessment and wear particle characterization. Results: Part I: The implant–abutment couplings underwent an active corrosion process resulting in metal ions released into the surrounding environment. The platform- matched groups demonstrated higher amount of metal ion release. Part II and Part III: Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of both the metal ions and the different implant-abutment couplings. The observed changes in some of the biological responses tested were more pronounced in groups representing the platform-matched implant-abutment couplings. Part IV: The implant–abutment couplings underwent an active tribocorrosion processes resulting in metal ions and wear particles released into the surrounding environment. The platform-matched groups demonstrated higher amount of metal ion release and more surface damage Conclusion: Platform-switching concept had a positive effect in reducing metal ion release and wear features from dental implants which in turn minimised the adverse osteoblastic biologic responses related to peri-implant bone loss, therefore highlighting the possible role of corrosion products in the mediation of crestal bone loss around dental implants","abstract_has_math":false,"creators":["Alrabeah, Ghada O."],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-03","date_published":"2019-03","updated_at":"2026-11-26T05:31:41Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10069911/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10069911/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10069911","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10069911","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Alrabeah, Ghada O."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-03-28"]},{"key":"dc:date.issued","label":"Date","values":["2019-03"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Eastman Dental Institute"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10069911/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Problem: The observed positive effect of the platform-switching concept on peri- implant bone level is not well understood. Dental implants may be prone to tribocorrosion leading to the release of metal ions and particles which may disrupt bone homeostasis Objectives: The aim of this project was to compare the amount of corrosion products released from different implant-abutment couplings with different connection geometries under accelerated corrosion tests, and to evaluate different osteoblastic cell responses to the released products. Materials and methods: Part I: Titanium cylinders were connected to titanium alloy (Ti-6Al-4V) and cobalt– chrome alloy abutments forming either platform-switched or platform-matched groups. Samples were subjected to static immersion in 1% lactic acid for 1 week. Metal ions released were measured and microscopic analyses were performed pre- and post- immersion to assess corrosion at the interface. Part II: Osteoblasts were treated with culture media containing different concentrations of metal ions obtained from the results of part I. Osteoblasts treated with ion-free culture medium served as the controls. Osteoblastic viability, apoptosis and expression of genes related to bone resorption were analysed. Part III: The samples used in part I were incubated with osteoblasts. Viability, apoptosis and expression of the genes tested in part II were investigated. Part IV: Titanium implants were coupled with either titanium, gold, cobalt-chrome, or zirconia abutments forming either platform-switched or platform-matched groups. The specimens were subjected to cyclic loading under wet acidic environment. Metal ions released were measured and microscopic evaluations were performed pre- and post- immersion for tribocorrosion assessment and wear particle characterization. Results: Part I: The implant–abutment couplings underwent an active corrosion process resulting in metal ions released into the surrounding environment. The platform- matched groups demonstrated higher amount of metal ion release. Part II and Part III: Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of both the metal ions and the different implant-abutment couplings. The observed changes in some of the biological responses tested were more pronounced in groups representing the platform-matched implant-abutment couplings. Part IV: The implant–abutment couplings underwent an active tribocorrosion processes resulting in metal ions and wear particles released into the surrounding environment. The platform-matched groups demonstrated higher amount of metal ion release and more surface damage Conclusion: Platform-switching concept had a positive effect in reducing metal ion release and wear features from dental implants which in turn minimised the adverse osteoblastic biologic responses related to peri-implant bone loss, therefore highlighting the possible role of corrosion products in the mediation of crestal bone loss around dental implants"]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["The Effect of Different Implant-Abutment Connection Geometry and Abutment Alloy on Corrosion Product Release and Cell Response"]}]}],"canonical_facts":{"dc:creator":["Alrabeah, Ghada O."],"dc:date":["2019-03-28"],"dc:date.issued":["2019-03"],"dc:description.abstract":["Problem: The observed positive effect of the platform-switching concept on peri- implant bone level is not well understood. Dental implants may be prone to tribocorrosion leading to the release of metal ions and particles which may disrupt bone homeostasis Objectives: The aim of this project was to compare the amount of corrosion products released from different implant-abutment couplings with different connection geometries under accelerated corrosion tests, and to evaluate different osteoblastic cell responses to the released products. Materials and methods: Part I: Titanium cylinders were connected to titanium alloy (Ti-6Al-4V) and cobalt– chrome alloy abutments forming either platform-switched or platform-matched groups. Samples were subjected to static immersion in 1% lactic acid for 1 week. Metal ions released were measured and microscopic analyses were performed pre- and post- immersion to assess corrosion at the interface. Part II: Osteoblasts were treated with culture media containing different concentrations of metal ions obtained from the results of part I. Osteoblasts treated with ion-free culture medium served as the controls. Osteoblastic viability, apoptosis and expression of genes related to bone resorption were analysed. Part III: The samples used in part I were incubated with osteoblasts. Viability, apoptosis and expression of the genes tested in part II were investigated. Part IV: Titanium implants were coupled with either titanium, gold, cobalt-chrome, or zirconia abutments forming either platform-switched or platform-matched groups. The specimens were subjected to cyclic loading under wet acidic environment. Metal ions released were measured and microscopic evaluations were performed pre- and post- immersion for tribocorrosion assessment and wear particle characterization. Results: Part I: The implant–abutment couplings underwent an active corrosion process resulting in metal ions released into the surrounding environment. The platform- matched groups demonstrated higher amount of metal ion release. Part II and Part III: Osteoblastic cell viability, apoptosis, and regulation of bone resorbing mediators were significantly altered in the presence of both the metal ions and the different implant-abutment couplings. The observed changes in some of the biological responses tested were more pronounced in groups representing the platform-matched implant-abutment couplings. Part IV: The implant–abutment couplings underwent an active tribocorrosion processes resulting in metal ions and wear particles released into the surrounding environment. The platform-matched groups demonstrated higher amount of metal ion release and more surface damage Conclusion: Platform-switching concept had a positive effect in reducing metal ion release and wear features from dental implants which in turn minimised the adverse osteoblastic biologic responses related to peri-implant bone loss, therefore highlighting the possible role of corrosion products in the mediation of crestal bone loss around dental implants"],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10069911/"],"dc:language":["en","eng"],"dc:publisher.department":["Eastman Dental Institute"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["The Effect of Different Implant-Abutment Connection Geometry and Abutment Alloy on Corrosion Product Release and Cell Response"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T05:31:41Z"}