{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10091153"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10091153","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"High energy x-ray implementation of phase contrast and dark field imaging","abstract":"X-ray phase contrast and dark field imaging are emerging imaging modalities which provide significantly enhanced visibility of details classically considered “x-ray invisible” and complementary information on a sample’s micro-structure, respectively. To date they have been successfully implemented in a series of applications at low x-ray energy, but their translation to higher x-ray energies is still, to some extent, problematic. Yet the ability to perform phase contrast and dark field imaging at high x-ray energy would have a series of significant implications in various applications, medical or otherwise. This thesis work investigates this option through a combination of modelling and experimental work. Particular attention has been dedicated to the behaviour of the optical elements (x-ray masks) that make phase contrast and dark field possible at high energy, which required the design of new methods of their implemention into simulation models. The modeling results have been validated first through a pilot experiment at a synchrotron facility, then in a series of lab experiments. Results clearly indicate that implementations of phase contrast and dark field imaging at high x-ray energy exist, however particular care must be taken in the design and fabrication of the masks; moreover, a series of parasitic effects which are absent at lower energies appear, which this thesis work describes and against which it suggests mitigation solutions.","abstract_html":"X-ray phase contrast and dark field imaging are emerging imaging modalities which provide significantly enhanced visibility of details classically considered “x-ray invisible” and complementary information on a sample’s micro-structure, respectively. To date they have been successfully implemented in a series of applications at low x-ray energy, but their translation to higher x-ray energies is still, to some extent, problematic. Yet the ability to perform phase contrast and dark field imaging at high x-ray energy would have a series of significant implications in various applications, medical or otherwise. This thesis work investigates this option through a combination of modelling and experimental work. Particular attention has been dedicated to the behaviour of the optical elements (x-ray masks) that make phase contrast and dark field possible at high energy, which required the design of new methods of their implemention into simulation models. The modeling results have been validated first through a pilot experiment at a synchrotron facility, then in a series of lab experiments. Results clearly indicate that implementations of phase contrast and dark field imaging at high x-ray energy exist, however particular care must be taken in the design and fabrication of the masks; moreover, a series of parasitic effects which are absent at lower energies appear, which this thesis work describes and against which it suggests mitigation solutions.","abstract_has_math":false,"creators":["Buchanan, Ian"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-02","date_published":"2020-02","updated_at":"2026-11-26T05:37:36Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10091153/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10091153/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10091153","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10091153","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Buchanan, Ian"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2020-02-28"]},{"key":"dc:date.issued","label":"Date","values":["2020-02"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10091153/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["X-ray phase contrast and dark field imaging are emerging imaging modalities which provide significantly enhanced visibility of details classically considered “x-ray invisible” and complementary information on a sample’s micro-structure, respectively. To date they have been successfully implemented in a series of applications at low x-ray energy, but their translation to higher x-ray energies is still, to some extent, problematic. Yet the ability to perform phase contrast and dark field imaging at high x-ray energy would have a series of significant implications in various applications, medical or otherwise. This thesis work investigates this option through a combination of modelling and experimental work. Particular attention has been dedicated to the behaviour of the optical elements (x-ray masks) that make phase contrast and dark field possible at high energy, which required the design of new methods of their implemention into simulation models. The modeling results have been validated first through a pilot experiment at a synchrotron facility, then in a series of lab experiments. Results clearly indicate that implementations of phase contrast and dark field imaging at high x-ray energy exist, however particular care must be taken in the design and fabrication of the masks; moreover, a series of parasitic effects which are absent at lower energies appear, which this thesis work describes and against which it suggests mitigation solutions."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["High energy x-ray implementation of phase contrast and dark field imaging"]}]}],"canonical_facts":{"dc:creator":["Buchanan, Ian"],"dc:date":["2020-02-28"],"dc:date.issued":["2020-02"],"dc:description.abstract":["X-ray phase contrast and dark field imaging are emerging imaging modalities which provide significantly enhanced visibility of details classically considered “x-ray invisible” and complementary information on a sample’s micro-structure, respectively. To date they have been successfully implemented in a series of applications at low x-ray energy, but their translation to higher x-ray energies is still, to some extent, problematic. Yet the ability to perform phase contrast and dark field imaging at high x-ray energy would have a series of significant implications in various applications, medical or otherwise. This thesis work investigates this option through a combination of modelling and experimental work. Particular attention has been dedicated to the behaviour of the optical elements (x-ray masks) that make phase contrast and dark field possible at high energy, which required the design of new methods of their implemention into simulation models. The modeling results have been validated first through a pilot experiment at a synchrotron facility, then in a series of lab experiments. Results clearly indicate that implementations of phase contrast and dark field imaging at high x-ray energy exist, however particular care must be taken in the design and fabrication of the masks; moreover, a series of parasitic effects which are absent at lower energies appear, which this thesis work describes and against which it suggests mitigation solutions."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10091153/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["High energy x-ray implementation of phase contrast and dark field imaging"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T05:37:36Z"}