{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10102693"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10102693","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Imaging and segmentation of bone in neurological magnetic resonance","abstract":"Magnetic resonance imaging (MRI) is a modality capable of providing excellent contrast for soft tissues, yet it provides very little information about bone, which, by contrast, can be seen clearly in CT images. This project attempts to remedy this limitation by expanding the visualisation capability of MRI to include details of skull boundary. The potential benefits of this advance include the accurate co-registration of MRI and CT or MRI and MRI image data, as used in frameless surgery planning; the avoidance of harmful radiation, a problem encountered in CT skull visualisation; modelling of electrical conductivity in the head; and cranioplasty planning. In addition, the method developed will potentially be helpful for the measurement of brain volume, especially small changes in voxel size, which is used in the quantitative assessment of changes in neurological diseases. Skull edge detection is made difficult due to the partial volume effect, strong edges between muscle and scalp, the thin appearance of the skull in the temporal region and strong edges near the superior sagittal sinus. Imaging artefacts including chemical shift and magnetic susceptibility shift have also been investigated quantitatively and qualitatively. To detect skull contours, a new fully automatic computer algorithm has been developed and the results of the method have been validated.","abstract_html":"Magnetic resonance imaging (MRI) is a modality capable of providing excellent contrast for soft tissues, yet it provides very little information about bone, which, by contrast, can be seen clearly in CT images. This project attempts to remedy this limitation by expanding the visualisation capability of MRI to include details of skull boundary. The potential benefits of this advance include the accurate co-registration of MRI and CT or MRI and MRI image data, as used in frameless surgery planning; the avoidance of harmful radiation, a problem encountered in CT skull visualisation; modelling of electrical conductivity in the head; and cranioplasty planning. In addition, the method developed will potentially be helpful for the measurement of brain volume, especially small changes in voxel size, which is used in the quantitative assessment of changes in neurological diseases. Skull edge detection is made difficult due to the partial volume effect, strong edges between muscle and scalp, the thin appearance of the skull in the temporal region and strong edges near the superior sagittal sinus. Imaging artefacts including chemical shift and magnetic susceptibility shift have also been investigated quantitatively and qualitatively. To detect skull contours, a new fully automatic computer algorithm has been developed and the results of the method have been validated.","abstract_has_math":false,"creators":["Yoo, Done-Sik"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1998,"date_issued":"1998","date_published":"1998","updated_at":"2026-11-26T06:26:08Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10102693/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10102693/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10102693","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10102693","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Yoo, Done-Sik"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1998"]},{"key":"dc:date.issued","label":"Date","values":["1998"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics and Bio-Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10102693/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Magnetic resonance imaging (MRI) is a modality capable of providing excellent contrast for soft tissues, yet it provides very little information about bone, which, by contrast, can be seen clearly in CT images. This project attempts to remedy this limitation by expanding the visualisation capability of MRI to include details of skull boundary. The potential benefits of this advance include the accurate co-registration of MRI and CT or MRI and MRI image data, as used in frameless surgery planning; the avoidance of harmful radiation, a problem encountered in CT skull visualisation; modelling of electrical conductivity in the head; and cranioplasty planning. In addition, the method developed will potentially be helpful for the measurement of brain volume, especially small changes in voxel size, which is used in the quantitative assessment of changes in neurological diseases. Skull edge detection is made difficult due to the partial volume effect, strong edges between muscle and scalp, the thin appearance of the skull in the temporal region and strong edges near the superior sagittal sinus. Imaging artefacts including chemical shift and magnetic susceptibility shift have also been investigated quantitatively and qualitatively. To detect skull contours, a new fully automatic computer algorithm has been developed and the results of the method have been validated."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Imaging and segmentation of bone in neurological magnetic resonance"]}]}],"canonical_facts":{"dc:creator":["Yoo, Done-Sik"],"dc:date":["1998"],"dc:date.issued":["1998"],"dc:description.abstract":["Magnetic resonance imaging (MRI) is a modality capable of providing excellent contrast for soft tissues, yet it provides very little information about bone, which, by contrast, can be seen clearly in CT images. This project attempts to remedy this limitation by expanding the visualisation capability of MRI to include details of skull boundary. The potential benefits of this advance include the accurate co-registration of MRI and CT or MRI and MRI image data, as used in frameless surgery planning; the avoidance of harmful radiation, a problem encountered in CT skull visualisation; modelling of electrical conductivity in the head; and cranioplasty planning. In addition, the method developed will potentially be helpful for the measurement of brain volume, especially small changes in voxel size, which is used in the quantitative assessment of changes in neurological diseases. Skull edge detection is made difficult due to the partial volume effect, strong edges between muscle and scalp, the thin appearance of the skull in the temporal region and strong edges near the superior sagittal sinus. Imaging artefacts including chemical shift and magnetic susceptibility shift have also been investigated quantitatively and qualitatively. To detect skull contours, a new fully automatic computer algorithm has been developed and the results of the method have been validated."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10102693/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics and Bio-Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Imaging and segmentation of bone in neurological magnetic resonance"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T06:26:08Z"}