{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10119396"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10119396","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"A Scintillator-Based Range Telescope for Particle Beam Radiotherapy","abstract":"Particle beam therapy (PBT) is a form of radiation therapy that is used for cancer treatment. Recently, interest in scintillator-based detectors for the measurement of depth-dose curves of therapeutic particle beams has been growing. In this work, a novel range telescope based on plastic scintillator and read out by a large-scale CMOS image sensor is presented. The detector is made of a stack of 49 plastic scintillator sheets with a thickness of 2–3mm and a transverse area of 100 times 100mm2. A novel Bragg curve model that incorporates scintillator quenching effects was developed for the beam range reconstruction from depth-light curves with low depthresolution. Measurements to characterise the performance of the detector were carried out at three different PBT centres across Europe. The maximum difference between the measured proton range and the reference range was found to be 0.46 mm. An evaluation of the radiation hardness proved that the range reconstruction algorithm is robust following the deposition of 6,300 Gy peak dose into the detector. Variations in the beam spot size, the transverse beam position and the beam intensity were shown to have a negligible effect on the range reconstruction accuracy. Range measurements of helium, carbon and oxygen ion beams were also performed. A novel technique for online range verification based on a mixed helium/ carbon ion beam and the range telescope was investigated. The helium beam range modulation by a narrow air gap of 1mm thickness in a plastic phantom that affected less than a quarter of the beam particles was detected, demonstrating the outstanding sensitivity of the mixed-beam technique. Using two anthropomorphic pelvis phantoms it was shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable range changes. The future prospects and limitations of the helium-carbon mixing as well as its technical feasibility are discussed.","abstract_html":"Particle beam therapy (PBT) is a form of radiation therapy that is used for cancer treatment. Recently, interest in scintillator-based detectors for the measurement of depth-dose curves of therapeutic particle beams has been growing. In this work, a novel range telescope based on plastic scintillator and read out by a large-scale CMOS image sensor is presented. The detector is made of a stack of 49 plastic scintillator sheets with a thickness of 2–3mm and a transverse area of 100 times 100mm2. A novel Bragg curve model that incorporates scintillator quenching effects was developed for the beam range reconstruction from depth-light curves with low depthresolution. Measurements to characterise the performance of the detector were carried out at three different PBT centres across Europe. The maximum difference between the measured proton range and the reference range was found to be 0.46 mm. An evaluation of the radiation hardness proved that the range reconstruction algorithm is robust following the deposition of 6,300 Gy peak dose into the detector. Variations in the beam spot size, the transverse beam position and the beam intensity were shown to have a negligible effect on the range reconstruction accuracy. Range measurements of helium, carbon and oxygen ion beams were also performed. A novel technique for online range verification based on a mixed helium/ carbon ion beam and the range telescope was investigated. The helium beam range modulation by a narrow air gap of 1mm thickness in a plastic phantom that affected less than a quarter of the beam particles was detected, demonstrating the outstanding sensitivity of the mixed-beam technique. Using two anthropomorphic pelvis phantoms it was shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable range changes. The future prospects and limitations of the helium-carbon mixing as well as its technical feasibility are discussed.","abstract_has_math":false,"creators":["Kelleter, Laurent"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Jolly, S"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-01","date_published":"2021-01","updated_at":"2026-11-26T06:45:41Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10119396/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10119396/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10119396","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10119396","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jolly, S"]},{"key":"dc:creator","label":"Author","values":["Kelleter, Laurent"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-01-28"]},{"key":"dc:date.issued","label":"Date","values":["2021-01"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics & Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10119396/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Particle beam therapy (PBT) is a form of radiation therapy that is used for cancer treatment. Recently, interest in scintillator-based detectors for the measurement of depth-dose curves of therapeutic particle beams has been growing. In this work, a novel range telescope based on plastic scintillator and read out by a large-scale CMOS image sensor is presented. The detector is made of a stack of 49 plastic scintillator sheets with a thickness of 2–3mm and a transverse area of 100 times 100mm2. A novel Bragg curve model that incorporates scintillator quenching effects was developed for the beam range reconstruction from depth-light curves with low depthresolution. Measurements to characterise the performance of the detector were carried out at three different PBT centres across Europe. The maximum difference between the measured proton range and the reference range was found to be 0.46 mm. An evaluation of the radiation hardness proved that the range reconstruction algorithm is robust following the deposition of 6,300 Gy peak dose into the detector. Variations in the beam spot size, the transverse beam position and the beam intensity were shown to have a negligible effect on the range reconstruction accuracy. Range measurements of helium, carbon and oxygen ion beams were also performed. A novel technique for online range verification based on a mixed helium/ carbon ion beam and the range telescope was investigated. The helium beam range modulation by a narrow air gap of 1mm thickness in a plastic phantom that affected less than a quarter of the beam particles was detected, demonstrating the outstanding sensitivity of the mixed-beam technique. Using two anthropomorphic pelvis phantoms it was shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable range changes. The future prospects and limitations of the helium-carbon mixing as well as its technical feasibility are discussed."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["A Scintillator-Based Range Telescope for Particle Beam Radiotherapy"]}]}],"canonical_facts":{"dc:contributor":["Jolly, S"],"dc:creator":["Kelleter, Laurent"],"dc:date":["2021-01-28"],"dc:date.issued":["2021-01"],"dc:description.abstract":["Particle beam therapy (PBT) is a form of radiation therapy that is used for cancer treatment. Recently, interest in scintillator-based detectors for the measurement of depth-dose curves of therapeutic particle beams has been growing. In this work, a novel range telescope based on plastic scintillator and read out by a large-scale CMOS image sensor is presented. The detector is made of a stack of 49 plastic scintillator sheets with a thickness of 2–3mm and a transverse area of 100 times 100mm2. A novel Bragg curve model that incorporates scintillator quenching effects was developed for the beam range reconstruction from depth-light curves with low depthresolution. Measurements to characterise the performance of the detector were carried out at three different PBT centres across Europe. The maximum difference between the measured proton range and the reference range was found to be 0.46 mm. An evaluation of the radiation hardness proved that the range reconstruction algorithm is robust following the deposition of 6,300 Gy peak dose into the detector. Variations in the beam spot size, the transverse beam position and the beam intensity were shown to have a negligible effect on the range reconstruction accuracy. Range measurements of helium, carbon and oxygen ion beams were also performed. A novel technique for online range verification based on a mixed helium/ carbon ion beam and the range telescope was investigated. The helium beam range modulation by a narrow air gap of 1mm thickness in a plastic phantom that affected less than a quarter of the beam particles was detected, demonstrating the outstanding sensitivity of the mixed-beam technique. Using two anthropomorphic pelvis phantoms it was shown that small rotations of the phantom as well as simulated bowel gas movements cause detectable range changes. The future prospects and limitations of the helium-carbon mixing as well as its technical feasibility are discussed."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10119396/"],"dc:language":["en","eng"],"dc:publisher.department":["Physics & Astronomy"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["A Scintillator-Based Range Telescope for Particle Beam Radiotherapy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T06:45:41Z"}