{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10138731"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10138731","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Radio-frequency atomic magnetometry with a rubidium Bose-Einstein condensate","abstract":"This thesis details progress in radio-frequency atomic magnetometry with ultracold rubidium atoms. Motivations and context are first covered, before an introduction of the main concepts required to understand the underlying physics is given. At first, a cold atom magnetometer is designed, built and characterised. Consistent 20 µK atoms are produced. Radio-frequency (RF) atomic magnetometry (AM) is performed by placing the atoms in a bias magnetic field and generating coherent precession with an external AC field. A noise floor at 330 pT/√Hz defines the sensor’s sensitivity, with a range of applications. RF-AM is then performed with a Bose-Einstein condensate (BEC). The 20 µK atoms are loaded into a magnetic trap, where RF evaporation increases their phase space density (PSD = nλ^3dB, n is the density and λdB is the thermal de Broglie wavelength of the atoms). Next, atoms are transferred into a hybrid dipole trap, collecting in a dimple created at the intersect of two high power laser beams. Production and stabilisation of these beams is described, which are focused down to a 75 µm beam waist at the trap position with a total power of 7 W. Optimisation of the evaporation process in both traps leads to consistent BEC production. A pure condensate with 4x10^4 atoms at 25 nK is reported. Radio-frequency magnetometry is performed at various probe volumes. With systematic optimisation a best AC sensitivity of 24 pT/√Hz with 3.4 × 10^8 atoms in the magnetic trap before evaporation is achieved. This is extended to the BEC with 4 × 10^4 atoms, where an AC sensitivity of 84 nT/√Hz and DC sensitivity of 14 nT/√Hz is reported, bringing previously achieved atomic magnetometry into the micrometer regime. A trade-off must be considered due to reduction in sensitivity at lower probe volumes. Volumes between 1.4×10−7 m^3 and 1.6×10−14 m^3 can be accessed, highlighting the sensors adaptability and tunability for different applications. The results are contextualised in the background of previously achieved magnetometers of various types. Finally, proof-of-concept electromagnetic induction imaging (EMI) measurements are made to confirm the sensor’s viability for high resolution imaging.","abstract_html":"This thesis details progress in radio-frequency atomic magnetometry with ultracold rubidium atoms. Motivations and context are first covered, before an introduction of the main concepts required to understand the underlying physics is given. At first, a cold atom magnetometer is designed, built and characterised. Consistent 20 µK atoms are produced. Radio-frequency (RF) atomic magnetometry (AM) is performed by placing the atoms in a bias magnetic field and generating coherent precession with an external AC field. A noise floor at 330 pT/√Hz defines the sensor’s sensitivity, with a range of applications. RF-AM is then performed with a Bose-Einstein condensate (BEC). The 20 µK atoms are loaded into a magnetic trap, where RF evaporation increases their phase space density (PSD = nλ^3dB, n is the density and λdB is the thermal de Broglie wavelength of the atoms). Next, atoms are transferred into a hybrid dipole trap, collecting in a dimple created at the intersect of two high power laser beams. Production and stabilisation of these beams is described, which are focused down to a 75 µm beam waist at the trap position with a total power of 7 W. Optimisation of the evaporation process in both traps leads to consistent BEC production. A pure condensate with 4x10^4 atoms at 25 nK is reported. Radio-frequency magnetometry is performed at various probe volumes. With systematic optimisation a best AC sensitivity of 24 pT/√Hz with 3.4 × 10^8 atoms in the magnetic trap before evaporation is achieved. This is extended to the BEC with 4 × 10^4 atoms, where an AC sensitivity of 84 nT/√Hz and DC sensitivity of 14 nT/√Hz is reported, bringing previously achieved atomic magnetometry into the micrometer regime. A trade-off must be considered due to reduction in sensitivity at lower probe volumes. Volumes between 1.4×10−7 m^3 and 1.6×10−14 m^3 can be accessed, highlighting the sensors adaptability and tunability for different applications. The results are contextualised in the background of previously achieved magnetometers of various types. Finally, proof-of-concept electromagnetic induction imaging (EMI) measurements are made to confirm the sensor’s viability for high resolution imaging.","abstract_has_math":false,"creators":["Cohen, Yuval"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-11","date_published":"2021-11","updated_at":"2026-11-26T07:26:09Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10138731/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10138731/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10138731","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10138731","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Cohen, Yuval"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-11-28"]},{"key":"dc:date.issued","label":"Date","values":["2021-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics & Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10138731/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis details progress in radio-frequency atomic magnetometry with ultracold rubidium atoms. Motivations and context are first covered, before an introduction of the main concepts required to understand the underlying physics is given. At first, a cold atom magnetometer is designed, built and characterised. Consistent 20 µK atoms are produced. Radio-frequency (RF) atomic magnetometry (AM) is performed by placing the atoms in a bias magnetic field and generating coherent precession with an external AC field. A noise floor at 330 pT/√Hz defines the sensor’s sensitivity, with a range of applications. RF-AM is then performed with a Bose-Einstein condensate (BEC). The 20 µK atoms are loaded into a magnetic trap, where RF evaporation increases their phase space density (PSD = nλ^3dB, n is the density and λdB is the thermal de Broglie wavelength of the atoms). Next, atoms are transferred into a hybrid dipole trap, collecting in a dimple created at the intersect of two high power laser beams. Production and stabilisation of these beams is described, which are focused down to a 75 µm beam waist at the trap position with a total power of 7 W. Optimisation of the evaporation process in both traps leads to consistent BEC production. A pure condensate with 4x10^4 atoms at 25 nK is reported. Radio-frequency magnetometry is performed at various probe volumes. With systematic optimisation a best AC sensitivity of 24 pT/√Hz with 3.4 × 10^8 atoms in the magnetic trap before evaporation is achieved. This is extended to the BEC with 4 × 10^4 atoms, where an AC sensitivity of 84 nT/√Hz and DC sensitivity of 14 nT/√Hz is reported, bringing previously achieved atomic magnetometry into the micrometer regime. A trade-off must be considered due to reduction in sensitivity at lower probe volumes. Volumes between 1.4×10−7 m^3 and 1.6×10−14 m^3 can be accessed, highlighting the sensors adaptability and tunability for different applications. The results are contextualised in the background of previously achieved magnetometers of various types. Finally, proof-of-concept electromagnetic induction imaging (EMI) measurements are made to confirm the sensor’s viability for high resolution imaging."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Radio-frequency atomic magnetometry with a rubidium Bose-Einstein condensate"]}]}],"canonical_facts":{"dc:creator":["Cohen, Yuval"],"dc:date":["2021-11-28"],"dc:date.issued":["2021-11"],"dc:description.abstract":["This thesis details progress in radio-frequency atomic magnetometry with ultracold rubidium atoms. Motivations and context are first covered, before an introduction of the main concepts required to understand the underlying physics is given. At first, a cold atom magnetometer is designed, built and characterised. Consistent 20 µK atoms are produced. Radio-frequency (RF) atomic magnetometry (AM) is performed by placing the atoms in a bias magnetic field and generating coherent precession with an external AC field. A noise floor at 330 pT/√Hz defines the sensor’s sensitivity, with a range of applications. RF-AM is then performed with a Bose-Einstein condensate (BEC). The 20 µK atoms are loaded into a magnetic trap, where RF evaporation increases their phase space density (PSD = nλ^3dB, n is the density and λdB is the thermal de Broglie wavelength of the atoms). Next, atoms are transferred into a hybrid dipole trap, collecting in a dimple created at the intersect of two high power laser beams. Production and stabilisation of these beams is described, which are focused down to a 75 µm beam waist at the trap position with a total power of 7 W. Optimisation of the evaporation process in both traps leads to consistent BEC production. A pure condensate with 4x10^4 atoms at 25 nK is reported. Radio-frequency magnetometry is performed at various probe volumes. With systematic optimisation a best AC sensitivity of 24 pT/√Hz with 3.4 × 10^8 atoms in the magnetic trap before evaporation is achieved. This is extended to the BEC with 4 × 10^4 atoms, where an AC sensitivity of 84 nT/√Hz and DC sensitivity of 14 nT/√Hz is reported, bringing previously achieved atomic magnetometry into the micrometer regime. A trade-off must be considered due to reduction in sensitivity at lower probe volumes. Volumes between 1.4×10−7 m^3 and 1.6×10−14 m^3 can be accessed, highlighting the sensors adaptability and tunability for different applications. The results are contextualised in the background of previously achieved magnetometers of various types. Finally, proof-of-concept electromagnetic induction imaging (EMI) measurements are made to confirm the sensor’s viability for high resolution imaging."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10138731/"],"dc:language":["en","eng"],"dc:publisher.department":["Physics & Astronomy"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Radio-frequency atomic magnetometry with a rubidium Bose-Einstein condensate"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:26:09Z"}