{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10139665"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10139665","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Development of micro-computed tomography for human fetal post-mortem imaging","abstract":"Perinatal autopsy is an essential way of assessing the cause of fetal loss during pregnancy. However, parents are reluctant to consent to an invasive autopsy. Modern imaging techniques can offer a non-invasive solution, but most current clinical techniques are unable to offer adequate image resolution for early gestation miscarriages, typically below 20weeks gestation or 300g body weight. This thesis describes evaluating micro-CT imaging for this purpose, culminating in developing a pragmatic clinical protocol. Within this thesis, five aspects are evaluated: 1. Scan preparation. The optimal concentration and immersion time for I2KI was established, with a formula to predict the immersion time required for full iodination. 2. Imaging parameters. Optimal micro-CT imaging parameters were investigated, comparing the signal-to-noise (SNR) and relative contrast-to-noise ratio (rCNR) across different settings. 3. Patient factors. The effect of demographics/external factors on image quality was evaluated. Maceration was identified as having the greatest detriment to image quality, yet high image quality was attained in the majority of scans. Fetal weight and number of projections were also noted to be positive predictors. 4. Image SNR / rCNR. Assessments were tested across whole fetus organ volumes with imaging parameters defined as 110kV, 200µA, 250ms, 2frames-per-projection, enabling a single anatomical area to be optimally imaged within a clinically relevant timeframe, <30minutes. 5. Parental experience. A pilot study consisting of parents who have experienced a miscarriage was also undertaken. Response to the technique was overwhelmingly positive, with key potential benefits being increased choice and uptake of autopsy investigations with multiple mental health benefits. Finally, the future direction of this work within the clinical setting is presented. The clinical impact of the research is to be able to offer parents a more acceptable non-invasive imaging investigation following miscarriage.","abstract_html":"Perinatal autopsy is an essential way of assessing the cause of fetal loss during pregnancy. However, parents are reluctant to consent to an invasive autopsy. Modern imaging techniques can offer a non-invasive solution, but most current clinical techniques are unable to offer adequate image resolution for early gestation miscarriages, typically below 20weeks gestation or 300g body weight. This thesis describes evaluating micro-CT imaging for this purpose, culminating in developing a pragmatic clinical protocol. Within this thesis, five aspects are evaluated: 1. Scan preparation. The optimal concentration and immersion time for I2KI was established, with a formula to predict the immersion time required for full iodination. 2. Imaging parameters. Optimal micro-CT imaging parameters were investigated, comparing the signal-to-noise (SNR) and relative contrast-to-noise ratio (rCNR) across different settings. 3. Patient factors. The effect of demographics/external factors on image quality was evaluated. Maceration was identified as having the greatest detriment to image quality, yet high image quality was attained in the majority of scans. Fetal weight and number of projections were also noted to be positive predictors. 4. Image SNR / rCNR. Assessments were tested across whole fetus organ volumes with imaging parameters defined as 110kV, 200µA, 250ms, 2frames-per-projection, enabling a single anatomical area to be optimally imaged within a clinically relevant timeframe, &lt;30minutes. 5. Parental experience. A pilot study consisting of parents who have experienced a miscarriage was also undertaken. Response to the technique was overwhelmingly positive, with key potential benefits being increased choice and uptake of autopsy investigations with multiple mental health benefits. Finally, the future direction of this work within the clinical setting is presented. The clinical impact of the research is to be able to offer parents a more acceptable non-invasive imaging investigation following miscarriage.","abstract_has_math":false,"creators":["Simcock, Ian Craig"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-26T07:26:44Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10139665/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10139665/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10139665","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10139665","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Simcock, Ian Craig"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["UCL GOS Institute of Child Health"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10139665/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Perinatal autopsy is an essential way of assessing the cause of fetal loss during pregnancy. However, parents are reluctant to consent to an invasive autopsy. Modern imaging techniques can offer a non-invasive solution, but most current clinical techniques are unable to offer adequate image resolution for early gestation miscarriages, typically below 20weeks gestation or 300g body weight. This thesis describes evaluating micro-CT imaging for this purpose, culminating in developing a pragmatic clinical protocol. Within this thesis, five aspects are evaluated: 1. Scan preparation. The optimal concentration and immersion time for I2KI was established, with a formula to predict the immersion time required for full iodination. 2. Imaging parameters. Optimal micro-CT imaging parameters were investigated, comparing the signal-to-noise (SNR) and relative contrast-to-noise ratio (rCNR) across different settings. 3. Patient factors. The effect of demographics/external factors on image quality was evaluated. Maceration was identified as having the greatest detriment to image quality, yet high image quality was attained in the majority of scans. Fetal weight and number of projections were also noted to be positive predictors. 4. Image SNR / rCNR. Assessments were tested across whole fetus organ volumes with imaging parameters defined as 110kV, 200µA, 250ms, 2frames-per-projection, enabling a single anatomical area to be optimally imaged within a clinically relevant timeframe, <30minutes. 5. Parental experience. A pilot study consisting of parents who have experienced a miscarriage was also undertaken. Response to the technique was overwhelmingly positive, with key potential benefits being increased choice and uptake of autopsy investigations with multiple mental health benefits. Finally, the future direction of this work within the clinical setting is presented. The clinical impact of the research is to be able to offer parents a more acceptable non-invasive imaging investigation following miscarriage."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of micro-computed tomography for human fetal post-mortem imaging"]}]}],"canonical_facts":{"dc:creator":["Simcock, Ian Craig"],"dc:date":["2021-12-28"],"dc:date.issued":["2021-12"],"dc:description.abstract":["Perinatal autopsy is an essential way of assessing the cause of fetal loss during pregnancy. However, parents are reluctant to consent to an invasive autopsy. Modern imaging techniques can offer a non-invasive solution, but most current clinical techniques are unable to offer adequate image resolution for early gestation miscarriages, typically below 20weeks gestation or 300g body weight. This thesis describes evaluating micro-CT imaging for this purpose, culminating in developing a pragmatic clinical protocol. Within this thesis, five aspects are evaluated: 1. Scan preparation. The optimal concentration and immersion time for I2KI was established, with a formula to predict the immersion time required for full iodination. 2. Imaging parameters. Optimal micro-CT imaging parameters were investigated, comparing the signal-to-noise (SNR) and relative contrast-to-noise ratio (rCNR) across different settings. 3. Patient factors. The effect of demographics/external factors on image quality was evaluated. Maceration was identified as having the greatest detriment to image quality, yet high image quality was attained in the majority of scans. Fetal weight and number of projections were also noted to be positive predictors. 4. Image SNR / rCNR. Assessments were tested across whole fetus organ volumes with imaging parameters defined as 110kV, 200µA, 250ms, 2frames-per-projection, enabling a single anatomical area to be optimally imaged within a clinically relevant timeframe, <30minutes. 5. Parental experience. A pilot study consisting of parents who have experienced a miscarriage was also undertaken. Response to the technique was overwhelmingly positive, with key potential benefits being increased choice and uptake of autopsy investigations with multiple mental health benefits. Finally, the future direction of this work within the clinical setting is presented. The clinical impact of the research is to be able to offer parents a more acceptable non-invasive imaging investigation following miscarriage."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10139665/"],"dc:language":["en","eng"],"dc:publisher.department":["UCL GOS Institute of Child Health"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Development of micro-computed tomography for human fetal post-mortem imaging"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:26:44Z"}