{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10141546"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10141546","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Remote ischaemic conditioning as a cardioprotective mechanism against anthracycline induced cardiac injury and multimodality monitoring of patients receiving anthracycline chemotherapy","abstract":"Introduction: Remote ischaemic conditioning was investigated as a cardioprotective strategy against anthracycline cardiotoxicity in the clinical setting. Identifying ways to best monitor these was also assessed. Methodology: A randomised double-blind controlled trial of remote ischaemic conditioning vs sham was performed in patients receiving anthracyclines. Conditioning was delivered with 4 cycles of 5-minute inflations/deflations prior to each chemotherapy cycle. High sensitivity troponin T was analysed at baseline, during chemotherapy and at follow-up. Echocardiography was performed at baseline and at follow-up. Arrhythmia assessment was performed during chemotherapy. Clinical events were documented at each visit. A cohort of patients had rapid sequence cardiac MRI and cardiac myosin binding protein C. The main outcome was change in troponin T between the two groups. Secondary outcomes included LV function, clinical events and arrhythmia outcomes. The relationship between peak troponin and secondary outcomes was assessed in a prospective observational manner. Results: Thirty-seven patients were randomly allocated to the remote ischaemic conditioning (n=19) or sham group (n=18). After excluding withdrawals, 16 patients in each group were included in the intention to treat analysis. Troponin T significantly increases during chemotherapy and peaks 1 month after. Regression analysis shows no difference in troponins between the groups during chemotherapy (mean difference 1.59ng/L, p=0.245) or follow-up (mean difference 0.62ng/L, p=0.744). Clinical events were similar. There was a significant trend towards more admissions with sepsis/neutropenia in the RIC group. There is a moderate correlation between peak troponin and total cumulative dose received (r=0.422, p=0.016) but no correlation with other outcomes. cMyC has a 4-fold median peak increase compared to 2-fold for TnT (p<0.001). Rapid sequence CMR is feasible (mean scanning time 14 minutes) and acceptable (85% acceptance rate). Conclusions: Remote ischaemic conditioning does not reduce anthracycline cardiotoxicity as assessed with troponin T despite a significant rise in troponin from chemotherapy.","abstract_html":"Introduction: Remote ischaemic conditioning was investigated as a cardioprotective strategy against anthracycline cardiotoxicity in the clinical setting. Identifying ways to best monitor these was also assessed. Methodology: A randomised double-blind controlled trial of remote ischaemic conditioning vs sham was performed in patients receiving anthracyclines. Conditioning was delivered with 4 cycles of 5-minute inflations/deflations prior to each chemotherapy cycle. High sensitivity troponin T was analysed at baseline, during chemotherapy and at follow-up. Echocardiography was performed at baseline and at follow-up. Arrhythmia assessment was performed during chemotherapy. Clinical events were documented at each visit. A cohort of patients had rapid sequence cardiac MRI and cardiac myosin binding protein C. The main outcome was change in troponin T between the two groups. Secondary outcomes included LV function, clinical events and arrhythmia outcomes. The relationship between peak troponin and secondary outcomes was assessed in a prospective observational manner. Results: Thirty-seven patients were randomly allocated to the remote ischaemic conditioning (n=19) or sham group (n=18). After excluding withdrawals, 16 patients in each group were included in the intention to treat analysis. Troponin T significantly increases during chemotherapy and peaks 1 month after. Regression analysis shows no difference in troponins between the groups during chemotherapy (mean difference 1.59ng/L, p=0.245) or follow-up (mean difference 0.62ng/L, p=0.744). Clinical events were similar. There was a significant trend towards more admissions with sepsis/neutropenia in the RIC group. There is a moderate correlation between peak troponin and total cumulative dose received (r=0.422, p=0.016) but no correlation with other outcomes. cMyC has a 4-fold median peak increase compared to 2-fold for TnT (p&lt;0.001). Rapid sequence CMR is feasible (mean scanning time 14 minutes) and acceptable (85% acceptance rate). Conclusions: Remote ischaemic conditioning does not reduce anthracycline cardiotoxicity as assessed with troponin T despite a significant rise in troponin from chemotherapy.","abstract_has_math":false,"creators":["Mallouppas, Michael"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021-12","date_published":"2021-12","updated_at":"2026-11-26T07:26:44Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10141546/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10141546/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10141546","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10141546","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Mallouppas, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2021-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2021-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Institute of Cardiovascular Science"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10141546/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Remote ischaemic conditioning was investigated as a cardioprotective strategy against anthracycline cardiotoxicity in the clinical setting. Identifying ways to best monitor these was also assessed. Methodology: A randomised double-blind controlled trial of remote ischaemic conditioning vs sham was performed in patients receiving anthracyclines. Conditioning was delivered with 4 cycles of 5-minute inflations/deflations prior to each chemotherapy cycle. High sensitivity troponin T was analysed at baseline, during chemotherapy and at follow-up. Echocardiography was performed at baseline and at follow-up. Arrhythmia assessment was performed during chemotherapy. Clinical events were documented at each visit. A cohort of patients had rapid sequence cardiac MRI and cardiac myosin binding protein C. The main outcome was change in troponin T between the two groups. Secondary outcomes included LV function, clinical events and arrhythmia outcomes. The relationship between peak troponin and secondary outcomes was assessed in a prospective observational manner. Results: Thirty-seven patients were randomly allocated to the remote ischaemic conditioning (n=19) or sham group (n=18). After excluding withdrawals, 16 patients in each group were included in the intention to treat analysis. Troponin T significantly increases during chemotherapy and peaks 1 month after. Regression analysis shows no difference in troponins between the groups during chemotherapy (mean difference 1.59ng/L, p=0.245) or follow-up (mean difference 0.62ng/L, p=0.744). Clinical events were similar. There was a significant trend towards more admissions with sepsis/neutropenia in the RIC group. There is a moderate correlation between peak troponin and total cumulative dose received (r=0.422, p=0.016) but no correlation with other outcomes. cMyC has a 4-fold median peak increase compared to 2-fold for TnT (p<0.001). Rapid sequence CMR is feasible (mean scanning time 14 minutes) and acceptable (85% acceptance rate). Conclusions: Remote ischaemic conditioning does not reduce anthracycline cardiotoxicity as assessed with troponin T despite a significant rise in troponin from chemotherapy."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Remote ischaemic conditioning as a cardioprotective mechanism against anthracycline induced cardiac injury and multimodality monitoring of patients receiving anthracycline chemotherapy"]}]}],"canonical_facts":{"dc:creator":["Mallouppas, Michael"],"dc:date":["2021-12-28"],"dc:date.issued":["2021-12"],"dc:description.abstract":["Introduction: Remote ischaemic conditioning was investigated as a cardioprotective strategy against anthracycline cardiotoxicity in the clinical setting. Identifying ways to best monitor these was also assessed. Methodology: A randomised double-blind controlled trial of remote ischaemic conditioning vs sham was performed in patients receiving anthracyclines. Conditioning was delivered with 4 cycles of 5-minute inflations/deflations prior to each chemotherapy cycle. High sensitivity troponin T was analysed at baseline, during chemotherapy and at follow-up. Echocardiography was performed at baseline and at follow-up. Arrhythmia assessment was performed during chemotherapy. Clinical events were documented at each visit. A cohort of patients had rapid sequence cardiac MRI and cardiac myosin binding protein C. The main outcome was change in troponin T between the two groups. Secondary outcomes included LV function, clinical events and arrhythmia outcomes. The relationship between peak troponin and secondary outcomes was assessed in a prospective observational manner. Results: Thirty-seven patients were randomly allocated to the remote ischaemic conditioning (n=19) or sham group (n=18). After excluding withdrawals, 16 patients in each group were included in the intention to treat analysis. Troponin T significantly increases during chemotherapy and peaks 1 month after. Regression analysis shows no difference in troponins between the groups during chemotherapy (mean difference 1.59ng/L, p=0.245) or follow-up (mean difference 0.62ng/L, p=0.744). Clinical events were similar. There was a significant trend towards more admissions with sepsis/neutropenia in the RIC group. There is a moderate correlation between peak troponin and total cumulative dose received (r=0.422, p=0.016) but no correlation with other outcomes. cMyC has a 4-fold median peak increase compared to 2-fold for TnT (p<0.001). Rapid sequence CMR is feasible (mean scanning time 14 minutes) and acceptable (85% acceptance rate). Conclusions: Remote ischaemic conditioning does not reduce anthracycline cardiotoxicity as assessed with troponin T despite a significant rise in troponin from chemotherapy."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10141546/"],"dc:language":["en","eng"],"dc:publisher.department":["Institute of Cardiovascular Science"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Remote ischaemic conditioning as a cardioprotective mechanism against anthracycline induced cardiac injury and multimodality monitoring of patients receiving anthracycline chemotherapy"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:26:44Z"}