{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10158274"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10158274","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Quantum Sensors for Electromagnetic Induction Imaging: from Atomic Vapours to Bose-Einstein Condensates","abstract":"In this thesis, two sensors for electromagnetic induction imaging (EMI) are presented based on radio-frequency atomic magnetometry (RF-AM) in alkali atoms. The first sensor addresses portability and real-world use of EMI with AMs, by housing the major components of the RF-AM within a lightweight, minaturised system that can be mechanically translated. The atomic source was provided by a thermal vapour of 87Rb and was pumped/probed on the D1 line. The performance of the sensor is detailed and an RF sensitivity of dBAC = 19pT/√Hz was achieved. Stability of the device was investigated and potential improvements to the design are discussed. EMI with the sensor is then tested by application to two real-world industrial problems. Through-skin pilot-hole detection in Al strut-skin arrangements and corrosion detection under thermal/electrical insulation. The mechanically translatable RF-AM was able to detect and localise pilot-holes of diameter 16 mm concealed by an Al skin of thickness 0.41 mm with sub-mm precision. For corrosion detection, localisation and depth detection of recesses in an Al plate was achieved when concealed with a 1.5 mm thick piece of rubber acting as an electrical/thermal insulator. The sensor demonstrates key advantages over existing solutions to these challenges in a package that is within the reach of real-world deployment. The second sensor addresses the spatial resolution limitations of thermal vapours, by instead utilising ultra-cold atoms trapped in a tight optical potential, as the atomic source for the RF-AM. Initially an existing 87Rb BEC setup is optimised and characterised. A BEC of 65k atoms is produced via optical evaporation with a final volume of 3.2×10^−8 cm^−3. The BEC RF sensitivity is measured to be 268pT/√Hz with a volumetric sensitivity of 50.2fT/(cm3/Hz). The BEC RF-AM is found not to be limited by the atomic projection noise and a strategy for further improvements is discussed.","abstract_html":"In this thesis, two sensors for electromagnetic induction imaging (EMI) are presented based on radio-frequency atomic magnetometry (RF-AM) in alkali atoms. The first sensor addresses portability and real-world use of EMI with AMs, by housing the major components of the RF-AM within a lightweight, minaturised system that can be mechanically translated. The atomic source was provided by a thermal vapour of 87Rb and was pumped/probed on the D1 line. The performance of the sensor is detailed and an RF sensitivity of dBAC = 19pT/√Hz was achieved. Stability of the device was investigated and potential improvements to the design are discussed. EMI with the sensor is then tested by application to two real-world industrial problems. Through-skin pilot-hole detection in Al strut-skin arrangements and corrosion detection under thermal/electrical insulation. The mechanically translatable RF-AM was able to detect and localise pilot-holes of diameter 16 mm concealed by an Al skin of thickness 0.41 mm with sub-mm precision. For corrosion detection, localisation and depth detection of recesses in an Al plate was achieved when concealed with a 1.5 mm thick piece of rubber acting as an electrical/thermal insulator. The sensor demonstrates key advantages over existing solutions to these challenges in a package that is within the reach of real-world deployment. The second sensor addresses the spatial resolution limitations of thermal vapours, by instead utilising ultra-cold atoms trapped in a tight optical potential, as the atomic source for the RF-AM. Initially an existing 87Rb BEC setup is optimised and characterised. A BEC of 65k atoms is produced via optical evaporation with a final volume of 3.2×10^−8 cm^−3. The BEC RF sensitivity is measured to be 268pT/√Hz with a volumetric sensitivity of 50.2fT/(cm3/Hz). The BEC RF-AM is found not to be limited by the atomic projection noise and a strategy for further improvements is discussed.","abstract_has_math":false,"creators":["Maddox, Benjamin Paul"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-10","date_published":"2022-10","updated_at":"2026-11-26T07:29:35Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10158274/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10158274/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10158274","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10158274","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Maddox, Benjamin Paul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-10-28"]},{"key":"dc:date.issued","label":"Date","values":["2022-10"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics & Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10158274/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this thesis, two sensors for electromagnetic induction imaging (EMI) are presented based on radio-frequency atomic magnetometry (RF-AM) in alkali atoms. The first sensor addresses portability and real-world use of EMI with AMs, by housing the major components of the RF-AM within a lightweight, minaturised system that can be mechanically translated. The atomic source was provided by a thermal vapour of 87Rb and was pumped/probed on the D1 line. The performance of the sensor is detailed and an RF sensitivity of dBAC = 19pT/√Hz was achieved. Stability of the device was investigated and potential improvements to the design are discussed. EMI with the sensor is then tested by application to two real-world industrial problems. Through-skin pilot-hole detection in Al strut-skin arrangements and corrosion detection under thermal/electrical insulation. The mechanically translatable RF-AM was able to detect and localise pilot-holes of diameter 16 mm concealed by an Al skin of thickness 0.41 mm with sub-mm precision. For corrosion detection, localisation and depth detection of recesses in an Al plate was achieved when concealed with a 1.5 mm thick piece of rubber acting as an electrical/thermal insulator. The sensor demonstrates key advantages over existing solutions to these challenges in a package that is within the reach of real-world deployment. The second sensor addresses the spatial resolution limitations of thermal vapours, by instead utilising ultra-cold atoms trapped in a tight optical potential, as the atomic source for the RF-AM. Initially an existing 87Rb BEC setup is optimised and characterised. A BEC of 65k atoms is produced via optical evaporation with a final volume of 3.2×10^−8 cm^−3. The BEC RF sensitivity is measured to be 268pT/√Hz with a volumetric sensitivity of 50.2fT/(cm3/Hz). The BEC RF-AM is found not to be limited by the atomic projection noise and a strategy for further improvements is discussed."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Quantum Sensors for Electromagnetic Induction Imaging: from Atomic Vapours to Bose-Einstein Condensates"]}]}],"canonical_facts":{"dc:creator":["Maddox, Benjamin Paul"],"dc:date":["2022-10-28"],"dc:date.issued":["2022-10"],"dc:description.abstract":["In this thesis, two sensors for electromagnetic induction imaging (EMI) are presented based on radio-frequency atomic magnetometry (RF-AM) in alkali atoms. The first sensor addresses portability and real-world use of EMI with AMs, by housing the major components of the RF-AM within a lightweight, minaturised system that can be mechanically translated. The atomic source was provided by a thermal vapour of 87Rb and was pumped/probed on the D1 line. The performance of the sensor is detailed and an RF sensitivity of dBAC = 19pT/√Hz was achieved. Stability of the device was investigated and potential improvements to the design are discussed. EMI with the sensor is then tested by application to two real-world industrial problems. Through-skin pilot-hole detection in Al strut-skin arrangements and corrosion detection under thermal/electrical insulation. The mechanically translatable RF-AM was able to detect and localise pilot-holes of diameter 16 mm concealed by an Al skin of thickness 0.41 mm with sub-mm precision. For corrosion detection, localisation and depth detection of recesses in an Al plate was achieved when concealed with a 1.5 mm thick piece of rubber acting as an electrical/thermal insulator. The sensor demonstrates key advantages over existing solutions to these challenges in a package that is within the reach of real-world deployment. The second sensor addresses the spatial resolution limitations of thermal vapours, by instead utilising ultra-cold atoms trapped in a tight optical potential, as the atomic source for the RF-AM. Initially an existing 87Rb BEC setup is optimised and characterised. A BEC of 65k atoms is produced via optical evaporation with a final volume of 3.2×10^−8 cm^−3. The BEC RF sensitivity is measured to be 268pT/√Hz with a volumetric sensitivity of 50.2fT/(cm3/Hz). The BEC RF-AM is found not to be limited by the atomic projection noise and a strategy for further improvements is discussed."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10158274/"],"dc:language":["en","eng"],"dc:publisher.department":["Physics & Astronomy"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Quantum Sensors for Electromagnetic Induction Imaging: from Atomic Vapours to Bose-Einstein Condensates"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:29:35Z"}