{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10162564"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10162564","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Development of an Innovative Biomechanical Model for Clinical Gait Analysis","abstract":"Work contained in this thesis describes a new biomechanical model for clinical gait analysis. Identified problems with current models are related to the subjective reasonableness of their underlying modelling assumptions and used to guide development of a new model. Gait scores were developed to evaluate alternative modelling solutions in terms of cycle average position, range, inter-cycle variability and movement pattern. An overly simple pro-forma model was developed to facilitate evaluation of the effects of complexity from alternative modelling approaches, both existing and newly developed. A clinical interpretation of Euler angles, widely used to describe joint orientations and movements, is presented. Leading directly from this interpretation, simple, joint-specific rules are derived that ensure calculated angles match clinical terminology. Other identified concerns are tackled on a per body-segment basis, with each segment presenting a different challenge. Identified problems with current trunk models were related to difficulties of orientating and tracking movement of the whole based on a selected sub-region. This was solved via the development of a more holistic solution, which additionally reduces the need for patient upper body exposure. For the pelvis and thigh segments, excessive soft tissue cover was identified as the major issue and resolved by the amalgamation of published methods with the novel introduction of fixed length thigh segments and a bespoke axial alignment calibration procedure. Foot model accuracy was improved by the application of bespoke calibration(s) that relates a defining flat foot posture to the position of surface markers, thus reducing the requirement for accurate placement over bony landmarks. Existing multi-segment foot models were grouped by a novel complexity index. Analysis of each group revealed an optimal balance with hind, medial forefoot, and lateral forefoot divisions. A model with this configuration was developed and outputs related to existing clinical terminology describing the foot shape.","abstract_html":"Work contained in this thesis describes a new biomechanical model for clinical gait analysis. Identified problems with current models are related to the subjective reasonableness of their underlying modelling assumptions and used to guide development of a new model. Gait scores were developed to evaluate alternative modelling solutions in terms of cycle average position, range, inter-cycle variability and movement pattern. An overly simple pro-forma model was developed to facilitate evaluation of the effects of complexity from alternative modelling approaches, both existing and newly developed. A clinical interpretation of Euler angles, widely used to describe joint orientations and movements, is presented. Leading directly from this interpretation, simple, joint-specific rules are derived that ensure calculated angles match clinical terminology. Other identified concerns are tackled on a per body-segment basis, with each segment presenting a different challenge. Identified problems with current trunk models were related to difficulties of orientating and tracking movement of the whole based on a selected sub-region. This was solved via the development of a more holistic solution, which additionally reduces the need for patient upper body exposure. For the pelvis and thigh segments, excessive soft tissue cover was identified as the major issue and resolved by the amalgamation of published methods with the novel introduction of fixed length thigh segments and a bespoke axial alignment calibration procedure. Foot model accuracy was improved by the application of bespoke calibration(s) that relates a defining flat foot posture to the position of surface markers, thus reducing the requirement for accurate placement over bony landmarks. Existing multi-segment foot models were grouped by a novel complexity index. Analysis of each group revealed an optimal balance with hind, medial forefoot, and lateral forefoot divisions. A model with this configuration was developed and outputs related to existing clinical terminology describing the foot shape.","abstract_has_math":false,"creators":["Thornton, Matthew James"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022-12","date_published":"2022-12","updated_at":"2026-11-26T07:30:10Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10162564/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10162564/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10162564","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10162564","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Thornton, Matthew James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2022-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2022-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Surgery & Interventional Sciences"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10162564/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Work contained in this thesis describes a new biomechanical model for clinical gait analysis. Identified problems with current models are related to the subjective reasonableness of their underlying modelling assumptions and used to guide development of a new model. Gait scores were developed to evaluate alternative modelling solutions in terms of cycle average position, range, inter-cycle variability and movement pattern. An overly simple pro-forma model was developed to facilitate evaluation of the effects of complexity from alternative modelling approaches, both existing and newly developed. A clinical interpretation of Euler angles, widely used to describe joint orientations and movements, is presented. Leading directly from this interpretation, simple, joint-specific rules are derived that ensure calculated angles match clinical terminology. Other identified concerns are tackled on a per body-segment basis, with each segment presenting a different challenge. Identified problems with current trunk models were related to difficulties of orientating and tracking movement of the whole based on a selected sub-region. This was solved via the development of a more holistic solution, which additionally reduces the need for patient upper body exposure. For the pelvis and thigh segments, excessive soft tissue cover was identified as the major issue and resolved by the amalgamation of published methods with the novel introduction of fixed length thigh segments and a bespoke axial alignment calibration procedure. Foot model accuracy was improved by the application of bespoke calibration(s) that relates a defining flat foot posture to the position of surface markers, thus reducing the requirement for accurate placement over bony landmarks. Existing multi-segment foot models were grouped by a novel complexity index. Analysis of each group revealed an optimal balance with hind, medial forefoot, and lateral forefoot divisions. A model with this configuration was developed and outputs related to existing clinical terminology describing the foot shape."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Development of an Innovative Biomechanical Model for Clinical Gait Analysis"]}]}],"canonical_facts":{"dc:creator":["Thornton, Matthew James"],"dc:date":["2022-12-28"],"dc:date.issued":["2022-12"],"dc:description.abstract":["Work contained in this thesis describes a new biomechanical model for clinical gait analysis. Identified problems with current models are related to the subjective reasonableness of their underlying modelling assumptions and used to guide development of a new model. Gait scores were developed to evaluate alternative modelling solutions in terms of cycle average position, range, inter-cycle variability and movement pattern. An overly simple pro-forma model was developed to facilitate evaluation of the effects of complexity from alternative modelling approaches, both existing and newly developed. A clinical interpretation of Euler angles, widely used to describe joint orientations and movements, is presented. Leading directly from this interpretation, simple, joint-specific rules are derived that ensure calculated angles match clinical terminology. Other identified concerns are tackled on a per body-segment basis, with each segment presenting a different challenge. Identified problems with current trunk models were related to difficulties of orientating and tracking movement of the whole based on a selected sub-region. This was solved via the development of a more holistic solution, which additionally reduces the need for patient upper body exposure. For the pelvis and thigh segments, excessive soft tissue cover was identified as the major issue and resolved by the amalgamation of published methods with the novel introduction of fixed length thigh segments and a bespoke axial alignment calibration procedure. Foot model accuracy was improved by the application of bespoke calibration(s) that relates a defining flat foot posture to the position of surface markers, thus reducing the requirement for accurate placement over bony landmarks. Existing multi-segment foot models were grouped by a novel complexity index. Analysis of each group revealed an optimal balance with hind, medial forefoot, and lateral forefoot divisions. A model with this configuration was developed and outputs related to existing clinical terminology describing the foot shape."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10162564/"],"dc:language":["en","eng"],"dc:publisher.department":["Surgery & Interventional Sciences"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Development of an Innovative Biomechanical Model for Clinical Gait Analysis"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:30:10Z"}