{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10180560"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10180560","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Magnetic Spectroscopy with Scintillation Detectors at the LUXE Experiment","abstract":"The success of the physical model of quantum electrodynamics relies on the use of a small perturbation above a quantum vacuum solution. In the physically possible case of a strong electric field, defined as being near or greater than the Schwinger limit, the assumption underlying this perturbation theory approach becomes unviable. In this new regime lies unexplored phenomena and a chance at new physics. The upcoming LUXE experiment at the Deutsches ElektronenSynchrotron intends to reach new parameter-space for intensity of an electric field, and access the strong regime. This is performed in two modes, with a modern high-power laser firing intense pulses at either accelerated bunches of electrons from the EU.XFEL (e-laser mode), or high-energy photons produced from the same EU.XFEL electron bunches (γ-laser mode). This thesis includes analysis of high-energy Bremsstrahlung emission, with the goal of accurately describing the flux of high-energy photons within the interaction point at LUXE. Presented here is the design and performance of operation of a magnetic spectrometer system, used to reconstruct the energy distributions of a flux of electrons, using a screen of scintillating material and optical cameras. This includes results from both simulation and using a prototype within test-beam. The Bremsstrahlung-related test-beam measurement resulted in a reconstructed polar angle profile which gives a reduction of maximum photon flux of 63% compared to the accepted model, if one assumes all measured discrepancy is due to inaccuracy in the theory. The suitability of the scintillator screen & camera system for LUXE is proven, in particular as the reconstruction of energy to ± 2% on a single-shot-basis is shown in simulation. The signal to noise ratio and dynamic range of the system, measured in test-beam, were included in the simulation.","abstract_html":"The success of the physical model of quantum electrodynamics relies on the use of a small perturbation above a quantum vacuum solution. In the physically possible case of a strong electric field, defined as being near or greater than the Schwinger limit, the assumption underlying this perturbation theory approach becomes unviable. In this new regime lies unexplored phenomena and a chance at new physics. The upcoming LUXE experiment at the Deutsches ElektronenSynchrotron intends to reach new parameter-space for intensity of an electric field, and access the strong regime. This is performed in two modes, with a modern high-power laser firing intense pulses at either accelerated bunches of electrons from the EU.XFEL (e-laser mode), or high-energy photons produced from the same EU.XFEL electron bunches (γ-laser mode). This thesis includes analysis of high-energy Bremsstrahlung emission, with the goal of accurately describing the flux of high-energy photons within the interaction point at LUXE. Presented here is the design and performance of operation of a magnetic spectrometer system, used to reconstruct the energy distributions of a flux of electrons, using a screen of scintillating material and optical cameras. This includes results from both simulation and using a prototype within test-beam. The Bremsstrahlung-related test-beam measurement resulted in a reconstructed polar angle profile which gives a reduction of maximum photon flux of 63% compared to the accepted model, if one assumes all measured discrepancy is due to inaccuracy in the theory. The suitability of the scintillator screen &amp; camera system for LUXE is proven, in particular as the reconstruction of energy to ± 2% on a single-shot-basis is shown in simulation. The signal to noise ratio and dynamic range of the system, measured in test-beam, were included in the simulation.","abstract_has_math":false,"creators":["Hallford, John Andrew"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-11","date_published":"2023-11","updated_at":"2026-11-26T07:33:35Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10180560/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10180560/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10180560","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10180560","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hallford, John Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-11-28"]},{"key":"dc:date.issued","label":"Date","values":["2023-11"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Physics & Astronomy"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10180560/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The success of the physical model of quantum electrodynamics relies on the use of a small perturbation above a quantum vacuum solution. In the physically possible case of a strong electric field, defined as being near or greater than the Schwinger limit, the assumption underlying this perturbation theory approach becomes unviable. In this new regime lies unexplored phenomena and a chance at new physics. The upcoming LUXE experiment at the Deutsches ElektronenSynchrotron intends to reach new parameter-space for intensity of an electric field, and access the strong regime. This is performed in two modes, with a modern high-power laser firing intense pulses at either accelerated bunches of electrons from the EU.XFEL (e-laser mode), or high-energy photons produced from the same EU.XFEL electron bunches (γ-laser mode). This thesis includes analysis of high-energy Bremsstrahlung emission, with the goal of accurately describing the flux of high-energy photons within the interaction point at LUXE. Presented here is the design and performance of operation of a magnetic spectrometer system, used to reconstruct the energy distributions of a flux of electrons, using a screen of scintillating material and optical cameras. This includes results from both simulation and using a prototype within test-beam. The Bremsstrahlung-related test-beam measurement resulted in a reconstructed polar angle profile which gives a reduction of maximum photon flux of 63% compared to the accepted model, if one assumes all measured discrepancy is due to inaccuracy in the theory. The suitability of the scintillator screen & camera system for LUXE is proven, in particular as the reconstruction of energy to ± 2% on a single-shot-basis is shown in simulation. The signal to noise ratio and dynamic range of the system, measured in test-beam, were included in the simulation."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Magnetic Spectroscopy with Scintillation Detectors at the LUXE Experiment"]}]}],"canonical_facts":{"dc:creator":["Hallford, John Andrew"],"dc:date":["2023-11-28"],"dc:date.issued":["2023-11"],"dc:description.abstract":["The success of the physical model of quantum electrodynamics relies on the use of a small perturbation above a quantum vacuum solution. In the physically possible case of a strong electric field, defined as being near or greater than the Schwinger limit, the assumption underlying this perturbation theory approach becomes unviable. In this new regime lies unexplored phenomena and a chance at new physics. The upcoming LUXE experiment at the Deutsches ElektronenSynchrotron intends to reach new parameter-space for intensity of an electric field, and access the strong regime. This is performed in two modes, with a modern high-power laser firing intense pulses at either accelerated bunches of electrons from the EU.XFEL (e-laser mode), or high-energy photons produced from the same EU.XFEL electron bunches (γ-laser mode). This thesis includes analysis of high-energy Bremsstrahlung emission, with the goal of accurately describing the flux of high-energy photons within the interaction point at LUXE. Presented here is the design and performance of operation of a magnetic spectrometer system, used to reconstruct the energy distributions of a flux of electrons, using a screen of scintillating material and optical cameras. This includes results from both simulation and using a prototype within test-beam. The Bremsstrahlung-related test-beam measurement resulted in a reconstructed polar angle profile which gives a reduction of maximum photon flux of 63% compared to the accepted model, if one assumes all measured discrepancy is due to inaccuracy in the theory. The suitability of the scintillator screen & camera system for LUXE is proven, in particular as the reconstruction of energy to ± 2% on a single-shot-basis is shown in simulation. The signal to noise ratio and dynamic range of the system, measured in test-beam, were included in the simulation."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10180560/"],"dc:language":["en","eng"],"dc:publisher.department":["Physics & Astronomy"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Magnetic Spectroscopy with Scintillation Detectors at the LUXE Experiment"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:33:35Z"}