{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10183385"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10183385","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications","abstract":"Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (< 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration.","abstract_html":"Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (&lt; 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration.","abstract_has_math":false,"creators":["Kiersnowski, Oliver C"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Shmueli, Karin","Thornton, John S"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023-12","date_published":"2023-12","updated_at":"2026-11-26T07:34:09Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10183385/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10183385/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10183385","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10183385","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Shmueli, Karin","Thornton, John S"]},{"key":"dc:creator","label":"Author","values":["Kiersnowski, Oliver C"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2023-12-28"]},{"key":"dc:date.issued","label":"Date","values":["2023-12"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10183385/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (< 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications"]}]}],"canonical_facts":{"dc:contributor":["Shmueli, Karin","Thornton, John S"],"dc:creator":["Kiersnowski, Oliver C"],"dc:date":["2023-12-28"],"dc:date.issued":["2023-12"],"dc:description.abstract":["Quantitative susceptibility mapping (QSM) is a magnetic resonance imaging (MRI) technique that utilises the phase of the complex MRI signal and a physics-based reconstruction pipeline to estimate the underlying tissue susceptibility distribution. QSM provides information on tissue composition such as iron content affected in several neurodegenerative diseases. The gold-standard sequence for acquiring data for QSM is a 3D gradient echo (GRE) sequence, with a whole-brain acquisition time of approximately 5 minutes. Echo planar imaging (EPI) sequences can acquire whole-brain volumes in a few seconds, allowing both structural and functional neuroimaging. I present work on translating QSM into clinical practice through investigating the effects of oblique slice acquisition, developing a robust method to correct for tilted slices or volumes. I also developed and optimised a robust QSM acquisition protocol and QSM reconstruction pipeline for neuroradiological imaging of patients with movement disorders; neuroradiologist scores based on image quality demonstrated their preference for iterative Tikhonov and Auto non-linear dipole inversion (NDI) susceptibility calculation methods over total variation-based regularised methods. I optimised a QSM reconstruction pipeline for investigations into tissue composition changes in patients with temporal lobe epilepsy (TLE), to find susceptibility and R2* differences in TLE patients compared to healthy controls, affecting the hippocampus, amygdala, thalamus and basal ganglia. A major portion of my research was to optimise the QSM acquisition and reconstruction pipeline for a multi-echo 2D EPI sequence for rapid (< 4 s repetition time) structural and functional QSM. This included: investigating the use of simultaneous multi-slice (SMS) acceleration which was found to provide accurate and rapid EPI-QSM; comparing single-echo and multi-echo EPI acquisitions for QSM; developing methods to reduce geometric distortion inherent to EPI sequences; and reducing artefacts in reconstructed susceptibility maps through optimising the QSM pipeline for multi-echo 2D-EPI. I applied the results of these investigations to present optimised structural QSM, preliminary functional QSM and functional MRI (fMRI) results from a 1.3 mm isotropic resolution multi-echo EPI sequence with 3-fold SMS and 4-fold GRAPPA acceleration."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10183385/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Optimising MRI Quantitative Susceptibility Mapping Techniques for Clinical Translation and Accelerated Structural and Functional Research Applications"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:34:09Z"}