{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10185274"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10185274","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Technical Evaluation of the World's First Simultaneous Clinical SPECT-MRI Imaging System","abstract":"This thesis outlines the analysis and evolution of a SPECT insert system designed for simultaneous use within a clinical MRI. The INSERT (INtegrated SPECT/MRI for Enhanced stratification of brain tumours in Radio-chemoTherapy) is the world’s first clinical SPECT-MRI brain imaging system based on scintillation detectors with a SiPM readout. This work demonstrates its use as a stand-alone SPECT scanner and a simultaneous SPECT-MRI. The use of a clinical SPECT-MRI is carried out here for the first time. The development of this novel technology is outlined, and its applications were investigated to establish the first-in-man study. The stand-alone SPECT scanner is evaluated, and its limitations are addressed through phantom studies in which techniques such as statistical image reconstruction, Monte Carlo simulations, and deep learning are deployed to solve issues with the SPECT design and performance. The system is used within a clinical environment and compared to established SPECT scanners to evaluate its feasibility as a clinical scanner. Finally, the INSERT is installed within an MRI and evaluated as a simultaneous clinical system. Hardware upgrades and development of specialised MRI imaging sequences allowed both systems to operate in unison. This body of work establishes the possibility of a simultaneous clinical SPECT-MRI. It looks to develop the technology further through patient trials and continued improvements of the clinical system.","abstract_html":"This thesis outlines the analysis and evolution of a SPECT insert system designed for simultaneous use within a clinical MRI. The INSERT (INtegrated SPECT/MRI for Enhanced stratification of brain tumours in Radio-chemoTherapy) is the world’s first clinical SPECT-MRI brain imaging system based on scintillation detectors with a SiPM readout. This work demonstrates its use as a stand-alone SPECT scanner and a simultaneous SPECT-MRI. The use of a clinical SPECT-MRI is carried out here for the first time. The development of this novel technology is outlined, and its applications were investigated to establish the first-in-man study. The stand-alone SPECT scanner is evaluated, and its limitations are addressed through phantom studies in which techniques such as statistical image reconstruction, Monte Carlo simulations, and deep learning are deployed to solve issues with the SPECT design and performance. The system is used within a clinical environment and compared to established SPECT scanners to evaluate its feasibility as a clinical scanner. Finally, the INSERT is installed within an MRI and evaluated as a simultaneous clinical system. Hardware upgrades and development of specialised MRI imaging sequences allowed both systems to operate in unison. This body of work establishes the possibility of a simultaneous clinical SPECT-MRI. It looks to develop the technology further through patient trials and continued improvements of the clinical system.","abstract_has_math":false,"creators":["Morahan, Ashley James"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-01","date_published":"2024-01","updated_at":"2026-11-26T07:34:09Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10185274/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10185274/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10185274","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10185274","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Morahan, Ashley James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-01-28"]},{"key":"dc:date.issued","label":"Date","values":["2024-01"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics & Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10185274/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis outlines the analysis and evolution of a SPECT insert system designed for simultaneous use within a clinical MRI. The INSERT (INtegrated SPECT/MRI for Enhanced stratification of brain tumours in Radio-chemoTherapy) is the world’s first clinical SPECT-MRI brain imaging system based on scintillation detectors with a SiPM readout. This work demonstrates its use as a stand-alone SPECT scanner and a simultaneous SPECT-MRI. The use of a clinical SPECT-MRI is carried out here for the first time. The development of this novel technology is outlined, and its applications were investigated to establish the first-in-man study. The stand-alone SPECT scanner is evaluated, and its limitations are addressed through phantom studies in which techniques such as statistical image reconstruction, Monte Carlo simulations, and deep learning are deployed to solve issues with the SPECT design and performance. The system is used within a clinical environment and compared to established SPECT scanners to evaluate its feasibility as a clinical scanner. Finally, the INSERT is installed within an MRI and evaluated as a simultaneous clinical system. Hardware upgrades and development of specialised MRI imaging sequences allowed both systems to operate in unison. This body of work establishes the possibility of a simultaneous clinical SPECT-MRI. It looks to develop the technology further through patient trials and continued improvements of the clinical system."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Technical Evaluation of the World's First Simultaneous Clinical SPECT-MRI Imaging System"]}]}],"canonical_facts":{"dc:creator":["Morahan, Ashley James"],"dc:date":["2024-01-28"],"dc:date.issued":["2024-01"],"dc:description.abstract":["This thesis outlines the analysis and evolution of a SPECT insert system designed for simultaneous use within a clinical MRI. The INSERT (INtegrated SPECT/MRI for Enhanced stratification of brain tumours in Radio-chemoTherapy) is the world’s first clinical SPECT-MRI brain imaging system based on scintillation detectors with a SiPM readout. This work demonstrates its use as a stand-alone SPECT scanner and a simultaneous SPECT-MRI. The use of a clinical SPECT-MRI is carried out here for the first time. The development of this novel technology is outlined, and its applications were investigated to establish the first-in-man study. The stand-alone SPECT scanner is evaluated, and its limitations are addressed through phantom studies in which techniques such as statistical image reconstruction, Monte Carlo simulations, and deep learning are deployed to solve issues with the SPECT design and performance. The system is used within a clinical environment and compared to established SPECT scanners to evaluate its feasibility as a clinical scanner. Finally, the INSERT is installed within an MRI and evaluated as a simultaneous clinical system. Hardware upgrades and development of specialised MRI imaging sequences allowed both systems to operate in unison. This body of work establishes the possibility of a simultaneous clinical SPECT-MRI. It looks to develop the technology further through patient trials and continued improvements of the clinical system."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10185274/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics & Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Technical Evaluation of the World's First Simultaneous Clinical SPECT-MRI Imaging System"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:34:09Z"}