{"id":{"repo_id":"ucl","oai_identifier":"oai:eprints.ucl.ac.uk.OAI2:10194265"},"canonical_url":"https://search.ndltd.org/etd/ucl/oai:eprints.ucl.ac.uk.OAI2:10194265","repository":{"repo_id":"ucl","name":"University College London","base_url":"https://discovery.ucl.ac.uk/cgi/oai2"},"display":{"title":"Innovative, CMOS-based sensor solutions for X-ray detection and dual-energy imaging","abstract":"Dual-energy single shot X-ray imaging is a cutting-edge technique that combines the benefits of both dual-energy imaging and single-shot acquisition in medical and industrial radiography. This approach allows for the simultaneous acquisition of two X-ray images at different energy levels in a single exposure, providing valuable information about material composition and density. The ability to perform dual energy in a single shot reduces motion artifacts and improves patient comfort, making it particularly advantageous in dynamic imaging scenarios. This thesis investigates the development of an optimal sandwich detector configuration for dual-energy single shot X-ray imaging that can be effectively used in various applications, including material discrimination (MD) and contrast cancellation (CC). The sandwich detector was designed and built by stacking two complementary metal oxide semiconductor (CMOS) active pixel sensors (APS) on top of each other, separated by an intermediate copper (Cu) filter to obtain the low energy (LE) and high energy images (HE) of the imaged object while utilising RQA5 (70 kV) beam quality as defined by the IEC 62220-1 standards. The sensors, top and bottom, are coupled with scintillators of appropriate thicknesses. The individual layers of the sandwich detector were subjected to detailed x-ray characterisation studies conducted while varying specific detector parameters. The optimal thicknesses of top scintillator and intermediate filter were determined by using a custom-developed dual energy algorithm model for material discrimination based on Azevedo’s SIRZ method, which allowed predicting dual-energy performance for a range of scintillator and Cu filter thicknesses. Finally, the validity of the model was tested experimentally with the developed sandwich detector with 0-, 0.25-, and 0.5-mm Cu filter thicknesses for both the MD and CC applications. This both provided promising results and showed good agreement between the model and experimental results.","abstract_html":"Dual-energy single shot X-ray imaging is a cutting-edge technique that combines the benefits of both dual-energy imaging and single-shot acquisition in medical and industrial radiography. This approach allows for the simultaneous acquisition of two X-ray images at different energy levels in a single exposure, providing valuable information about material composition and density. The ability to perform dual energy in a single shot reduces motion artifacts and improves patient comfort, making it particularly advantageous in dynamic imaging scenarios. This thesis investigates the development of an optimal sandwich detector configuration for dual-energy single shot X-ray imaging that can be effectively used in various applications, including material discrimination (MD) and contrast cancellation (CC). The sandwich detector was designed and built by stacking two complementary metal oxide semiconductor (CMOS) active pixel sensors (APS) on top of each other, separated by an intermediate copper (Cu) filter to obtain the low energy (LE) and high energy images (HE) of the imaged object while utilising RQA5 (70 kV) beam quality as defined by the IEC 62220-1 standards. The sensors, top and bottom, are coupled with scintillators of appropriate thicknesses. The individual layers of the sandwich detector were subjected to detailed x-ray characterisation studies conducted while varying specific detector parameters. The optimal thicknesses of top scintillator and intermediate filter were determined by using a custom-developed dual energy algorithm model for material discrimination based on Azevedo’s SIRZ method, which allowed predicting dual-energy performance for a range of scintillator and Cu filter thicknesses. Finally, the validity of the model was tested experimentally with the developed sandwich detector with 0-, 0.25-, and 0.5-mm Cu filter thicknesses for both the MD and CC applications. This both provided promising results and showed good agreement between the model and experimental results.","abstract_has_math":false,"creators":["Palakkappilly Alikunju, Rimcy"],"institution":"UCL (University College London)","degree_name":null,"degree_level":"Doctoral","degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024-07","date_published":"2024-07","updated_at":"2026-11-26T07:36:24Z","subjects":[],"languages":["en","eng"],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://discovery.ucl.ac.uk/id/eprint/10194265/","outbound_label":"Repository record","outbound_source":"dc:identifier.uri","record_url":"https://discovery.ucl.ac.uk/id/eprint/10194265/","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Aucl%3Aoai%3Aeprints.ucl.ac.uk.OAI2%3A10194265","prefix":"oai_dc"},"source_record":{"url":"https://discovery.ucl.ac.uk/cgi/oai2?verb=GetRecord&metadataPrefix=uketd_dc&identifier=oai%3Aeprints.ucl.ac.uk.OAI2%3A10194265","prefix":"uketd_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Palakkappilly Alikunju, Rimcy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2024-07-28"]},{"key":"dc:date.issued","label":"Date","values":["2024-07"]},{"key":"dc:publisher.department","label":"Dc Publisher Department","values":["Medical Physics and Biomedical Engineering"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["UCL (University College London)"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.qualificationlevel","label":"Dc Type Qualificationlevel","values":["Doctoral"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en","eng"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://discovery.ucl.ac.uk/id/eprint/10194265/"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Dual-energy single shot X-ray imaging is a cutting-edge technique that combines the benefits of both dual-energy imaging and single-shot acquisition in medical and industrial radiography. This approach allows for the simultaneous acquisition of two X-ray images at different energy levels in a single exposure, providing valuable information about material composition and density. The ability to perform dual energy in a single shot reduces motion artifacts and improves patient comfort, making it particularly advantageous in dynamic imaging scenarios. This thesis investigates the development of an optimal sandwich detector configuration for dual-energy single shot X-ray imaging that can be effectively used in various applications, including material discrimination (MD) and contrast cancellation (CC). The sandwich detector was designed and built by stacking two complementary metal oxide semiconductor (CMOS) active pixel sensors (APS) on top of each other, separated by an intermediate copper (Cu) filter to obtain the low energy (LE) and high energy images (HE) of the imaged object while utilising RQA5 (70 kV) beam quality as defined by the IEC 62220-1 standards. The sensors, top and bottom, are coupled with scintillators of appropriate thicknesses. The individual layers of the sandwich detector were subjected to detailed x-ray characterisation studies conducted while varying specific detector parameters. The optimal thicknesses of top scintillator and intermediate filter were determined by using a custom-developed dual energy algorithm model for material discrimination based on Azevedo’s SIRZ method, which allowed predicting dual-energy performance for a range of scintillator and Cu filter thicknesses. Finally, the validity of the model was tested experimentally with the developed sandwich detector with 0-, 0.25-, and 0.5-mm Cu filter thicknesses for both the MD and CC applications. This both provided promising results and showed good agreement between the model and experimental results."]},{"key":"dc:format","label":"Dc Format","values":["text"]},{"key":"dcterms:accessrights","label":"Dcterms Accessrights","values":["public"]},{"key":"dc:title","label":"Title","values":["Innovative, CMOS-based sensor solutions for X-ray detection and dual-energy imaging"]}]}],"canonical_facts":{"dc:creator":["Palakkappilly Alikunju, Rimcy"],"dc:date":["2024-07-28"],"dc:date.issued":["2024-07"],"dc:description.abstract":["Dual-energy single shot X-ray imaging is a cutting-edge technique that combines the benefits of both dual-energy imaging and single-shot acquisition in medical and industrial radiography. This approach allows for the simultaneous acquisition of two X-ray images at different energy levels in a single exposure, providing valuable information about material composition and density. The ability to perform dual energy in a single shot reduces motion artifacts and improves patient comfort, making it particularly advantageous in dynamic imaging scenarios. This thesis investigates the development of an optimal sandwich detector configuration for dual-energy single shot X-ray imaging that can be effectively used in various applications, including material discrimination (MD) and contrast cancellation (CC). The sandwich detector was designed and built by stacking two complementary metal oxide semiconductor (CMOS) active pixel sensors (APS) on top of each other, separated by an intermediate copper (Cu) filter to obtain the low energy (LE) and high energy images (HE) of the imaged object while utilising RQA5 (70 kV) beam quality as defined by the IEC 62220-1 standards. The sensors, top and bottom, are coupled with scintillators of appropriate thicknesses. The individual layers of the sandwich detector were subjected to detailed x-ray characterisation studies conducted while varying specific detector parameters. The optimal thicknesses of top scintillator and intermediate filter were determined by using a custom-developed dual energy algorithm model for material discrimination based on Azevedo’s SIRZ method, which allowed predicting dual-energy performance for a range of scintillator and Cu filter thicknesses. Finally, the validity of the model was tested experimentally with the developed sandwich detector with 0-, 0.25-, and 0.5-mm Cu filter thicknesses for both the MD and CC applications. This both provided promising results and showed good agreement between the model and experimental results."],"dc:format":["text"],"dc:identifier.uri":["https://discovery.ucl.ac.uk/id/eprint/10194265/"],"dc:language":["en","eng"],"dc:publisher.department":["Medical Physics and Biomedical Engineering"],"dc:publisher.institution":["UCL (University College London)"],"dcterms:accessrights":["public"],"dc:title":["Innovative, CMOS-based sensor solutions for X-ray detection and dual-energy imaging"],"dc:type":["Thesis"],"dc:type.qualificationlevel":["Doctoral"]},"updated_at":"2026-11-26T07:36:24Z"}